Malfunction
Activity
More information
Vacuum bag is not sealed cor-
rectly.
•
Check the seal settings
of the program and adjust
them.
•
Check/replace the Teflon
tape and the sealing wires.
•
Check/replace the silicone
rubber of the silicone hold-
ers.
•
Check the inside of the va-
cuum for contamination and
clean it.
Operation on page 23.
Replacing the Sealing Wire on
page 55.
Replacing the Silicone Rubber
of the Silicone Holders on page
56.
Error messages for the 10-PCS
Malfunction
Activity
More information
F1 in display.
•
Check or adjust the switch
of the lid.
•
Verify that the vacuum pump
is running.
Contact your supplier.
F2 in display of the 10-PCS
with sensor control.
•
Check whether the lid is
open and restart the ma-
chine.
•
If the message appears
again, please contact your
supplier.
Contact your supplier.
--- in display.
•
Check whether the lid is
open.
Flashing "C" in display.
•
This is a reminder to run the
pump cleaning program.
Run the pump cleaning pro-
gram.
Oil Notification (if activated).
A service check is needed.
Contact your supplier.
Error messages for the ACS
Malfunction
Activity
More information
Message "Sensor missing" in
display.
•
Check whether the sensor is
connected.
Troubleshooting and Error Codes 63