No.
Element
Explanation
1.
Program number/name
The program shows the currently selected, pre-set pro-
gram. By switching to a different program, other func-
tions will be activated. The program selection depends
on the product being packaged.
2.
Functions
These functions are active or inactive. If a function is
active, it is displayed in a blue shade. If a function is in-
active, it is displayed in a grey shade.
3.
Function active/inactive
The selected function is marked with a green circle.
The name and current value of this function will appear
on the screen.
If the + functions are activated, the + is indicated in
colour. If these functions are not active, they are dis-
played in a grey shade.
4.
Menu
The machine settings can be adjusted via the Menu
pictogram at the left of the function overview.
1.
Press the
▲
or
▼
buttons to select the desired program.
2.
Press the
◄
or
►
buttons to view the functions.
3.
After selecting the desired function, press Enter to view and adjust the function settings.
Users can view the pre-set configuration and the owner is also authorised to change it.
4.
Select the Machine Settings menu and press Enter to adjust the machine settings.
This menu can only be accessed by the owner. See Guideline for Function Values on page
51 for the possible limit values of the function values.
6.2.5.1 Programming the ACS Control Using the PC
You can import labels and programmes from a USB stick by inserting the stick into the USB port
of your machine. You can create the data to be imported using the online software that is available
on: http://acs-configurator.com.
Before you set-up the next program or label, please make sure you have saved the
previous one.
Follow the steps below:
1.
Click on the link of the LX Software.
2.
Click on the Programmes or Labels button, to start your settings. You can also click on
Select a file to import to import existing programmes and/or labels from the machine.
3.
Enter the necessary information.
4.
Click on Save to save the program or label.
Each program and label should be stored separately using the Save button.
Operation 39