8

USER DISPLAYS/SETTINGS

General Operation

When the system is operating one of two displays
will  be  shown.    Pressing  NEXT  will  alternate
between  the  displays.    One  of  the  displays  is
always  the  current  time  of  day.    The  second
display is gallons remaining.  This is the number
of gallons that will be treated before the system
goes  through  a  regeneration  cycle.    The  user
can scroll between the displays as desired.

If softener is a time clock system, the number of
days remaining until the next regeneration will
be displayed instead of gallons remaining.

If the system has called for a regeneration that will
occur at the preset time of regeneration, the words
“REGEN TODAY” will appear on the display.

When water is being treated (i.e. water is flowing
through  the  system)  the  word  “SOFTENING”
flashes on the display.

Figure 10

Regeneration Mode

Typically a system is set to regenerate at a time of low water usage.  An example
of a time with low water usage is when the household is asleep.  If there is a demand
for water when the system is regenerating, untreated water will be supplied.

When  the  system  begins  to  regenerate,  the  display  will  change  to  include
information about the step of the regeneration process and the time remaining for
that step to be completed.  The system runs through the steps automatically and
will reset itself to provide treated water when the regeneration has been completed.

Manual Regeneration

Sometimes there is a need to regenerate the system, sooner than when the
system calls for it, usually referred to as manual regeneration.  There may be
a period of heavy water usage because of guests or a heavy laundry day.

To  initiate  a  manual  regeneration  at  the  preset  delayed  regeneration
time, press and release “REGEN”.  The words “REGEN TODAY” will flash
on the display to indicate that the system will regenerate at the preset
delayed regeneration time.  If you pressed the “REGEN” button in error,
pressing the button again will cancel the request.

To initiate a manual regeneration immediately,

 press and hold the “REGEN”

button for three seconds.  The system will begin to regenerate immediately.
The request cannot be cancelled.  You must cycle all the way through the cycles to make it stop.  PLEASE NOTE:  This will reset the meter.

Note:  If the salt keeper does not contain salt, fill with salt and wait at least two hours before regenerating.

Regeneration Step #2

(shows time remaining in regen step is 8:22)

Figure 11

Figure 12

WATER SOFTENER DISINFECTION

The  materials  of  construction  of  your  water  softener  will  not
support bacterial growth nor will these materials contaminate a
water supply. However, the normal conditions existing during
shipping, storage, and installation indicate the advisability of
disinfecting a softener after installation, before the softener is
used to treat potable water. In addition, during normal use a
softener may become fouled with organic matter or in some
cases, with bacteria from the water supply.

Therefore,  every  water  softener  should  be  disinfected

after installation, some will require periodic disinfection during
their normal life. Disinfect as follows:

SODIUM HYPOCHLORITE (household bleach)

5.25%  SODIUM  HYPOCHLORITE  solutions  are  available

under such trade names such as Clorox, Linco, Bo Peep,
White Sail and Eagle Brand Bleach. If stronger solutions
are  used,  such  as  those  sold  for  commercial  laundries,
adjust the dosage accordingly.
1. Dosage:

a. Softening  resin;  1.2  fluid  ounce  per  cubic  foot  of

mineral (see page 18).

2. Add the required amount of hypochlorite solution to the

brine well of the brine tank.
a. Proceed with the normal regeneration.  Press regen

and allow the water softener to go through a normal
regeneration.

All manuals and user guides at all-guides.com

Содержание Economical Water Conditioning System Series H-100

Страница 1: ...05 Manufactured by HELLENBRAND INC 404 Moravian Valley Road Waunakee Wisconsin 53597 Phone 608 849 3050 Fax 608 849 7398 Web www hellenbrand com Email info hellenbrand com All manuals and user guides...

Страница 2: ...g your water softener please contact the dealer who installed this system TABLE OF CONTENTS Job Specification Sheet Page 2 Operating Conditions 2 Soft Water Basics 3 Frequenty Asked Questions 3 Pre In...

Страница 3: ...for buildup of insoluble materials It is recommended to periodically clean the salt keeper no matter what kind of salt you are using See page 9 miscellaneous 2 for details on cleaning REMEMBER Salt is...

Страница 4: ...s built up heavily with lime and or iron must be replaced If piping is blocked with iron additional equipment must be installed ahead of the water conditioner to correct the problem Drain Line The con...

Страница 5: ...o connecting the drain line flow control fitting Leave at least 6 between the drain line control fitting and solder joints when soldering pipes that are connected on the drain line control fitting Fai...

Страница 6: ...starts coming out of the drain line open the by pass inlet valve all the way and allow to run out the drain until water clears Then slowly place the by pass into the normal operation mode by opening t...

Страница 7: ...it Installer Displays Settings Step 3 Day Override This sets the number of days between regenerations If value set to oFF regeneration initiation is based solely on gallons used If value is set as a n...

Страница 8: ...TODAY will flash on the display to indicate that the system will regenerate at the preset delayed regeneration time If you pressed the REGEN button in error pressing the button again will cancel the r...

Страница 9: ...uns downward and is unobstructed When brine water quits running at the drain be sure to leave the drain valve open until you start the system up again 5 At this time the salt keeper has very little wa...

Страница 10: ...en main or regenerant piston G Replace main or regenerant piston 3 Control valve does not regenerate A Transformer unplugged A Connect transformer automaticallly when REGEN button B No electric power...

Страница 11: ...er ahead of softener C Resin bed mushing due to high amount C Rebed softener Install dechlorinaton system of oxidizers in water supply chlorine 14 Iron in softened water A Iron has fouled resin bed A...

Страница 12: ...y 18x40 Blue 1 3 S75 1 c Brine Tank Assy 24x41 Black 1 3 531100302221 3 d Brine Tank Assy 24x50 Black 1 3 551100302221 3 7 3 8 x 6 Brine Line 1 2 H1023 06 8a 18x33 Brine Tank Tank Blue 1 2 1833BL b 18...

Страница 13: ...the software version ex 154 and then reset the valve to the service position Do not use vaseline oils other hydrocarbon lubricants or spray silicone anywhere A silicon lubricant may be used on black o...

Страница 14: ...washes injector plugs are located in both holes The nuts and caps are designed to be unscrewed or tightened by hand or with the special plastic wrench If necessary a pliers can be used to unscrew the...

Страница 15: ...pe wrench to tighten or loosen nuts or caps Do not place screwdriver in slots on caps and or tap with a hammer Do not use pipe dope or other sealants on threads Teflon tape must be used on threads of...

Страница 16: ...ts and caps are designed to be unscrewed or tightened by hand or with the special plastic wrench If necessary a pliers can be used to unscrew the nut or cap Do not use a pipe wrench to tighten or loos...

Страница 17: ...1 15 V3151 Nut 1 Quick Connect 2 2 15 V3150 Split Ring 2 3 15 V3105 O Ring 215 2 4 15 V3188 01 Fitting 3 4 Brass Sweat 2 1 4 15 V3007 03 Fitting 3 4 Brass Sweat Asy 1 QTY ITEM NO ORDER NO DESCRIPTION...

Страница 18: ...060 28 060 42 090 56 120 84 180 112 240 140 300 168 360 High Salting 24 230 32 310 32 310 48 460 64 620 96 930 129 240 161 550 193 860 Water Usage U S Gallons Normal Backwash Longer Backwash High Max...

Страница 19: ...timated Regeneration occurs at the next Regen Set Time when gallons capacity reaches 0 or the specified number of days between regenerations is reached AUTO On 0 oFF Reserve capacity not automatically...

Страница 20: ...E ARE EXPRESSLY LIMITED TO A TERM OF TWO 2 YEARS SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU As a manufacturer we do not kno...