TROUBLE SHOOTING

PROBLEM

CAUSE

CORRECTION

1.ERROR followed by code number

Error Code 1001

 - Unable to recognize

A.

Control valve has just been serviced

A.

Press NEXT and REGEN for 3 seconds or

start of regeneration

unplug power source jack from PC Board (black
wire) and plug back in to reset control valve

Error Code 1002

 - Unexpected stall

B.

Foreign matter is lodged in control valve

B.

Check piston and spacer stack assembly
for foreign matter

Error Code 1003

 - Motor ran to long,

C. High drive forces on piston

C. Loosen drive cap assembly 1/4 turn or replace

timed out trying to reach next cycle

piston and spacer stack assembly

position

Error Code 1004

 - Motor ran to long,

D1. Control valve piston not in home position

D1. Press NEXT and REGEN for 3 seconds or unplug

timed out trying to reach home

power source jack (black wire) and plug back in

position

to reset control valve

D2. Motor not inserted fully to engage pinion,

D2. Check motor and wiring.  Replace motor if

motor wires broken or disconnected,

necessary

motor failure

D3. Drive gear label dirty or damaged,

D3. Replace or clean drive gear

If other Error Codes display

missing or broken gear

contact the factory

D4. Drive bracket incorrectly aligned to

D4. Reset drive bracket

back plate

D5. PC board is damaged or defective

D5. Replace PC board

D6. PC board incorrectly aligned to

D6. Ensure PC board is correctly snapped on to

drive bracket

drive bracket

Error Code 4003

E.

Miscommunication through board or

E.

Unplug, re-plug in, if this does not resolve problem

Low voltage through board

replace PC board

2. Control valve stalled in regeneration

A.

Motor not operating

A.

Replace Motor

B.

No electric power at outlet

B.

Repair outlet our use working outlet

C. Defective transformer

C. Replace transformer

D. Defective PC board

D. Replace PC board

E.

Broken drive gear or drive cap assembly

E.

Replace drive gear or drive cap assembly

F.

Broken piston retainer

F.

Replace drive cap assembly

G. Broken main or regenerant piston

G. Replace main or regenerant piston

3. Control valve does not regenerate

A.

Transformer unplugged

A.

Connect transformer

automaticallly when REGEN button

B.

No electric power at outlet

B.

Repair outlet or use working outlet

is depressed and held

C. Broken drive gear or drive cap assembly

C. Replace drive gear or drive cap assembly

D. Defective PC board

D. Replace PC board

4. Control valve does not regenerate

A.

By-pass valve in bypass position

A.

Put control valve in service position

automatically but does when

B.

Meter connection disconnected

B.

Connect meter to PC board

REGEN button is depressed

C. Restricted/stalled meter turbine

C. Remove meter and check for rotation

or foreign matter

D. Defective meter

D. Replace meter

E.

Defective PC board

E.

Replace PC board

F.

Set-up error

F.

Check control valve set-up procedure

5. Time of day flashes on and off

A.

Power has been out more than two hours,

A.

Reset the time of day

the transformer was unplugged and then
plugged back into the wall outlet, the
transformer plug was unplugged and then
plugged back into the board or the NEXT
and REGEN buttons were pressed to
reset the valve

6. Softener delivers hard water.

A.

Bypass valve is open or faulty.

A.

Close bypass valve or replace.

B.

No salt or low salt level in brine tank.

B.

Add salt to brine tank and maintain salt level
above water level.

C. Softener fails to draw brine.

C. See problem #11.

D. Excessive water usage.

D. Check gallon capacity settings.

E.

Insufficient brine level in brine tank.

E.

Check brine refill setting and refill flow restrictor for
blockage.

F.

Resin level inadequate.

F.

See problem #8.

G. Meter faulty.

G. Test meter and clean or replace meter.

H. Raw water hardness fluctuation.

H. Test raw water hardness and adjust settings to

highest known hardness.

7. Unit uses too much salt.

A.

Improper brine refill setting.

A.

Check  brine  refill  setting  for  proper  salt  dosage

B.

Improper settings.

B.

Check water hardness and reevaluate capacity setting
specification

C. Excessive water in brine tank.

C. See problem #10.

D. Leaking faucets, toilets, etc...

D. Repair or replace those items.

All manuals and user guides at all-guides.com

Содержание Economical Water Conditioning System Series H-100

Страница 1: ...05 Manufactured by HELLENBRAND INC 404 Moravian Valley Road Waunakee Wisconsin 53597 Phone 608 849 3050 Fax 608 849 7398 Web www hellenbrand com Email info hellenbrand com All manuals and user guides...

Страница 2: ...g your water softener please contact the dealer who installed this system TABLE OF CONTENTS Job Specification Sheet Page 2 Operating Conditions 2 Soft Water Basics 3 Frequenty Asked Questions 3 Pre In...

Страница 3: ...for buildup of insoluble materials It is recommended to periodically clean the salt keeper no matter what kind of salt you are using See page 9 miscellaneous 2 for details on cleaning REMEMBER Salt is...

Страница 4: ...s built up heavily with lime and or iron must be replaced If piping is blocked with iron additional equipment must be installed ahead of the water conditioner to correct the problem Drain Line The con...

Страница 5: ...o connecting the drain line flow control fitting Leave at least 6 between the drain line control fitting and solder joints when soldering pipes that are connected on the drain line control fitting Fai...

Страница 6: ...starts coming out of the drain line open the by pass inlet valve all the way and allow to run out the drain until water clears Then slowly place the by pass into the normal operation mode by opening t...

Страница 7: ...it Installer Displays Settings Step 3 Day Override This sets the number of days between regenerations If value set to oFF regeneration initiation is based solely on gallons used If value is set as a n...

Страница 8: ...TODAY will flash on the display to indicate that the system will regenerate at the preset delayed regeneration time If you pressed the REGEN button in error pressing the button again will cancel the r...

Страница 9: ...uns downward and is unobstructed When brine water quits running at the drain be sure to leave the drain valve open until you start the system up again 5 At this time the salt keeper has very little wa...

Страница 10: ...en main or regenerant piston G Replace main or regenerant piston 3 Control valve does not regenerate A Transformer unplugged A Connect transformer automaticallly when REGEN button B No electric power...

Страница 11: ...er ahead of softener C Resin bed mushing due to high amount C Rebed softener Install dechlorinaton system of oxidizers in water supply chlorine 14 Iron in softened water A Iron has fouled resin bed A...

Страница 12: ...y 18x40 Blue 1 3 S75 1 c Brine Tank Assy 24x41 Black 1 3 531100302221 3 d Brine Tank Assy 24x50 Black 1 3 551100302221 3 7 3 8 x 6 Brine Line 1 2 H1023 06 8a 18x33 Brine Tank Tank Blue 1 2 1833BL b 18...

Страница 13: ...the software version ex 154 and then reset the valve to the service position Do not use vaseline oils other hydrocarbon lubricants or spray silicone anywhere A silicon lubricant may be used on black o...

Страница 14: ...washes injector plugs are located in both holes The nuts and caps are designed to be unscrewed or tightened by hand or with the special plastic wrench If necessary a pliers can be used to unscrew the...

Страница 15: ...pe wrench to tighten or loosen nuts or caps Do not place screwdriver in slots on caps and or tap with a hammer Do not use pipe dope or other sealants on threads Teflon tape must be used on threads of...

Страница 16: ...ts and caps are designed to be unscrewed or tightened by hand or with the special plastic wrench If necessary a pliers can be used to unscrew the nut or cap Do not use a pipe wrench to tighten or loos...

Страница 17: ...1 15 V3151 Nut 1 Quick Connect 2 2 15 V3150 Split Ring 2 3 15 V3105 O Ring 215 2 4 15 V3188 01 Fitting 3 4 Brass Sweat 2 1 4 15 V3007 03 Fitting 3 4 Brass Sweat Asy 1 QTY ITEM NO ORDER NO DESCRIPTION...

Страница 18: ...060 28 060 42 090 56 120 84 180 112 240 140 300 168 360 High Salting 24 230 32 310 32 310 48 460 64 620 96 930 129 240 161 550 193 860 Water Usage U S Gallons Normal Backwash Longer Backwash High Max...

Страница 19: ...timated Regeneration occurs at the next Regen Set Time when gallons capacity reaches 0 or the specified number of days between regenerations is reached AUTO On 0 oFF Reserve capacity not automatically...

Страница 20: ...E ARE EXPRESSLY LIMITED TO A TERM OF TWO 2 YEARS SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU As a manufacturer we do not kno...

Отзывы: