5

Do not use vaseline, oils, other hydrocarbon lubricants or
spray silicone anywhere.  A silicon lubricant may be used on
black  o-rings  but  is  not  necessary.   

Avoid  any  type  of

lubricants, including silicone, on red or clear lip seals.

Do not use pipe dope or other sealants on threads.  Only
teflon  tape  may  be  used  on  threads.    Teflon  tape  is  not
necessary on the nut connection or caps because of radial
o-ring seals.

The pipe size for the drain line should be a minimum of 3/4”.
Backwash flow rates in excess of 10 gpm or length in excess
of 20’ require 1” drain line.

1. Place the conditioner where you want to install it, making

sure it is on a clean, level and firm base.

2. Do all necessary plumbing (inlet to inlet, outlet to outlet and

drain line to drain).  The control valve, fittings and/or bypass
are  designed  to  accommodate  minor  plumbing
misalignments but are not designed to support the weight of
a system or the plumbing.

3. When assembling the installation fitting package (inlet and

outlet), connect the fitting to the plumbing system first and
then attach the nut, split ring and o-ring.  Heat from soldering
or solvent cements may damage the nut, split ring or o-ring.
Solder joints should be cool and solvent cements should be
set  before  installing  the  nut,  split  ring  and  o-ring.    Avoid
getting primer and solvent cement on any part of the o-rings,
split rings, bypass valve or control valve.

4. A jumper ground wire should be installed between the

inlet and outlet pipe whenever the metallic continuity of
a water distribution piping system is interrupted.  In-
stall grounding strap on metal pipes.

5. The drain connection may be made using either 5/8” polytube

(See figure 6a, page 5) or a 3/4” female adaper.  If soldering,
joints near the drain must be done prior to connecting the
drain line flow control fitting.  Leave at least 6” between the
drain line control fitting and solder  joints when soldering
pipes  that  are  connected  on  the  drain  line  control  fitting.
Failure to do this could cause interior damage to the drain
line flow control fitting.

6. The brine refill flow control assembly is installed in an easy

to access refill elbow located on top of the control valve.  The
refill flow control assembly is attached to the control valve
with  a  locking  clip.    The  locking  clip  allows  the  elbow  to
rotate 270 degrees so the outlet can be orientated towards
the salt keeper.

7. Connect the brine line found in the salt keeper to the brine

connection on the control valve.  The control valve has a
standard refill elbow to which a 3/8” flexible tube can be
connected, see figure 6a, page 5.  (An optional elbow can
be ordered which accommodates a 1/2” flexible tube for a
high regenerant draw rate situation).  Both elbows use the
same refill flow control and retainer.  Do not connect the
other end of the brine line to the safety brine valve in the salt
keeper at this time. Make sure the floor is clean beneath the
salt tank and that it is level and smooth.  No grid is required with
standard brine tank as softener is programming as prefill.

8. A 1/2” (inside diameter) gravity drain line may be connected

to the overflow fitting on the side of the salt keeper. This
overflow is in case of a malfunction in the brine shut off. If
the unit is installed where water may flow in the event of an
overflow  and  cause  water  damage,  connect  a  length  of
flexible  tubing  and  run  to  a  drain  below  the  level  of  the
overflow. 

(Do not connect the tubing to the drain line on

the control valve.  Do not run tubing above overflow
height at any point.)

Figure 6a

Figure 6b

INSTALLATION INSTRUCTIONS

(All electrical & plumbing should be done in accordance to all local codes)

Drain
Connection

Brine Line
Connecton

All manuals and user guides at all-guides.com

Содержание Economical Water Conditioning System Series H-100

Страница 1: ...05 Manufactured by HELLENBRAND INC 404 Moravian Valley Road Waunakee Wisconsin 53597 Phone 608 849 3050 Fax 608 849 7398 Web www hellenbrand com Email info hellenbrand com All manuals and user guides...

Страница 2: ...g your water softener please contact the dealer who installed this system TABLE OF CONTENTS Job Specification Sheet Page 2 Operating Conditions 2 Soft Water Basics 3 Frequenty Asked Questions 3 Pre In...

Страница 3: ...for buildup of insoluble materials It is recommended to periodically clean the salt keeper no matter what kind of salt you are using See page 9 miscellaneous 2 for details on cleaning REMEMBER Salt is...

Страница 4: ...s built up heavily with lime and or iron must be replaced If piping is blocked with iron additional equipment must be installed ahead of the water conditioner to correct the problem Drain Line The con...

Страница 5: ...o connecting the drain line flow control fitting Leave at least 6 between the drain line control fitting and solder joints when soldering pipes that are connected on the drain line control fitting Fai...

Страница 6: ...starts coming out of the drain line open the by pass inlet valve all the way and allow to run out the drain until water clears Then slowly place the by pass into the normal operation mode by opening t...

Страница 7: ...it Installer Displays Settings Step 3 Day Override This sets the number of days between regenerations If value set to oFF regeneration initiation is based solely on gallons used If value is set as a n...

Страница 8: ...TODAY will flash on the display to indicate that the system will regenerate at the preset delayed regeneration time If you pressed the REGEN button in error pressing the button again will cancel the r...

Страница 9: ...uns downward and is unobstructed When brine water quits running at the drain be sure to leave the drain valve open until you start the system up again 5 At this time the salt keeper has very little wa...

Страница 10: ...en main or regenerant piston G Replace main or regenerant piston 3 Control valve does not regenerate A Transformer unplugged A Connect transformer automaticallly when REGEN button B No electric power...

Страница 11: ...er ahead of softener C Resin bed mushing due to high amount C Rebed softener Install dechlorinaton system of oxidizers in water supply chlorine 14 Iron in softened water A Iron has fouled resin bed A...

Страница 12: ...y 18x40 Blue 1 3 S75 1 c Brine Tank Assy 24x41 Black 1 3 531100302221 3 d Brine Tank Assy 24x50 Black 1 3 551100302221 3 7 3 8 x 6 Brine Line 1 2 H1023 06 8a 18x33 Brine Tank Tank Blue 1 2 1833BL b 18...

Страница 13: ...the software version ex 154 and then reset the valve to the service position Do not use vaseline oils other hydrocarbon lubricants or spray silicone anywhere A silicon lubricant may be used on black o...

Страница 14: ...washes injector plugs are located in both holes The nuts and caps are designed to be unscrewed or tightened by hand or with the special plastic wrench If necessary a pliers can be used to unscrew the...

Страница 15: ...pe wrench to tighten or loosen nuts or caps Do not place screwdriver in slots on caps and or tap with a hammer Do not use pipe dope or other sealants on threads Teflon tape must be used on threads of...

Страница 16: ...ts and caps are designed to be unscrewed or tightened by hand or with the special plastic wrench If necessary a pliers can be used to unscrew the nut or cap Do not use a pipe wrench to tighten or loos...

Страница 17: ...1 15 V3151 Nut 1 Quick Connect 2 2 15 V3150 Split Ring 2 3 15 V3105 O Ring 215 2 4 15 V3188 01 Fitting 3 4 Brass Sweat 2 1 4 15 V3007 03 Fitting 3 4 Brass Sweat Asy 1 QTY ITEM NO ORDER NO DESCRIPTION...

Страница 18: ...060 28 060 42 090 56 120 84 180 112 240 140 300 168 360 High Salting 24 230 32 310 32 310 48 460 64 620 96 930 129 240 161 550 193 860 Water Usage U S Gallons Normal Backwash Longer Backwash High Max...

Страница 19: ...timated Regeneration occurs at the next Regen Set Time when gallons capacity reaches 0 or the specified number of days between regenerations is reached AUTO On 0 oFF Reserve capacity not automatically...

Страница 20: ...E ARE EXPRESSLY LIMITED TO A TERM OF TWO 2 YEARS SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU As a manufacturer we do not kno...

Отзывы: