19
TABLE 4 - BACKWASH NORMAL LENGTH SOFTENER
Down Flow Softener* Factory Settings
Up Flow Softener
6000 to 3501
3500 to 2501
2500 to 1700
6000 to 3501
3500 to 2501
2500 to 1700
Backwash Normal
6
8*
8
---
---
---
Regenerate
45
60*
75
45
60
75
Backwash Normal
3
8*
10
6
10
12
Rinse
3
4*
6
3
4
6
Total
57
80*
99
54
74
93
Cycle Time
in minutes
Grains Capacity/Lb NaCl
TABLE 5 - BACKWASH LONGER LENGTH SOFTENER
Down Flow Softener
Up Flow Softener
6000 to 3501
3500 to 2501
2500 to 1700
6000 to 3501
3500 to 2501
2500 to 1700
Backwash Normal
8
10
12
---
---
---
Regenerate
45
60
75
45
60
75
Backwash Normal
8
10
12
6
12
14
Rinse
4
6
8
3
4
6
Total
65
86
107
54
76
95
Cycle Time
in minutes
Grains Capacity/Lb NaCl
TABLE 6 - PROGRAMMING OPTIONS
AUTO
NORMAL
oFF
Reserve capacity automatically estimated.
Regeneration occurs when gallons capacity falls below the reserve capacity at
the next Regen Set Time.
AUTO
NORMAL
1 to 24
Reserve capacity automatically estimated.
Regeneration occurs at the next Regen Set Time when gallons capacity
falls below the reserve capacity or the specified number of days between
regenerations is reached.
20 to
50,000
NORMAL
oFF
Reserve capacity not automatically estimated.
Regeneration occurs at the next Regen Set Time when gallons capacity
reaches 0.
1 to 24**
NORMAL**
oFF**
Reserve capacity not automatically estimated.
Regeneration occurs at the next Regen Set Time when the specified number
of days between regenerations is reached.
20 to
50,000
NORMAL
1 to 24
Reserve capacity not automatically estimated.
Regeneration occurs at the next Regen Set Time when gallons capacity
reaches 0 or the specified number of days between regenerations is reached.
AUTO
On 0
oFF
Reserve capacity not automatically estimated.
Regeneration occurs immediately when gallons capacity reaches 0.
Time of regeneration will not be allowed to be set because of regeneration will
always occur when gallons capacity reaches 0.
20 to
50,000
On 0
oFF
Reserve capacity not automatically estimated.
Regeneration occurs immediately when gallons capacity reaches 0.
Time of regeneration will not be allowed to be set because regeneration will
always occur on 0.
AUTO
NORMAL on 0
oFF
Reserve capacity automatically estimated.
Regeneration occurs when gallons capacity falls below the reserve
capacity at the next Regen Set Time or regeneration occurs immediately after
10 minutes of no water usage when gallon capacity reaches 0.
AUTO*
NORMAL on 0*
1 to 24
*14
Reserve capacity automatically estimated.
Regeneration occurs at the next Regen Set Time when gallons capacity
falls below the reserve capacity or the specified number of days between
regenerations is reached or regeneration occurs immediately after 10
minutes of no water usage when gallon capacity reaches 0.
20 to
50,000
NORMAL
1 to 24
Reserve capacity not automatically estimated.
Regeneration occurs at the next Regen Set Time when specified number of
days between regenerations is reached or regeneration occurs immediately
after 10 minutes of no water usage when gallon capacity reaches 0.
* Factory settings in bold
** These settings are used for time clock systems
Reserve
Gallons
Regeneration
Type
Days
Override