background image

20

73-360

7/05 - 2,500

Updated 10/18/05

Hellenbrand, Inc., warrants to the original consumer/purchaser against defects in material and/or workmanship from the date of

the original installation as follows:

For a Period of 

FIVE YEARS

: The control valve including electrical parts, internal parts, and valve body.

For a Period of 

TEN YEARS

: Mineral tanks, 6” Diameter - 13” Diameter.

For a Period of 

FIVE YEARS

: Mineral tanks, 14” - Up.

For a Period of 

FIVE YEARS

: The salt storage/cabinet tank.

For a Period of 

ONE YEAR

: Any other component.

Any parts used for replacement are warranted for the remainder of the original warranty period.
If a part described above becomes defective within the specified period, you should notify your Hellenbrand Series100 dealer and

arrange a time during normal business hours for the dealer to inspect the water conditioner on your premises. Any part found defective
within the terms of this warranty will be repaired or replaced by him. You pay only freight from our factory and local dealer charges.

THIS WARRANTY DOES NOT COVER

 defects caused by sand, sediment or bacteria fouling, accident, fire, flood, Act of God,

misuse, misapplication, neglect, alteration, installation or operation contrary to our printed instructions, or repair or service by
anyone other than the factory or authorized Hellenbrand dealer.

Our performance specifications are furnished with each water conditioning unit. 

ANY EXPRESS WARRANTY NOT PROVIDED

HEREIN, AND ANY REMEDY FOR BREACH OF CONTRACT WHICH BUT FOR THIS PROVISION MIGHT ARISE BY IMPLICATION
OR OPERATION OF LAW, IS HEREBY EXCLUDED AND DISCLAIMED. THE IMPLIED WARRANTIES OF MERCHANTABILITY
AND  OF  FITNESS  FOR  ANY  PARTICULAR  PURPOSE  ARE  EXPRESSLY  LIMITED  TO  A  TERM  OF  TWO  (2)  YEARS.  SOME
STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS, SO THE ABOVE LIMITATION MAY
NOT APPLY TO YOU.

As a manufacturer, we do not know the characteristics of your water supply or the purpose for which you are purchasing this water

conditioner. Please understand the quality of water supplies may vary seasonally or over a period of time, and that your water usage
rate may vary as well. Water characteristics can also change considerably if your water conditioner is moved to a new location. For these
reasons, we assume no liability for the determination of the proper equipment necessary to meet your requirements and we do not
authorize others to assume such obligations for us.

UNDER NO CIRCUMSTANCES SHALL HELLENBRAND, INC., BE LIABLE TO PURCHASER OR TO ANY OTHER PERSON

FOR ANY INCIDENTAL, SPECIAL, OR CONSEQUENTIAL DAMAGES OR FOR ANY OTHER LOSS, DAMAGE, OR EXPENSE OF
ANY KIND, INCLUDING LOSS OF PROFITS, WHETHER ARISING OUT OF BREACH OF WARRANTY, BREACH OF CONTRACT,
OR OTHERWISE.

Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion

may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

HELLENBRAND H-100 SERIES WARRANTY

OPERATING PRESSURES

Minimum/Maximum ................................................................................................................................. 25 psi-120 psi

OPERATING TEMPERATURES

Minimum/Maximum ................................................................................................................................. 40º - 110º F

METER

Accuracy .................................................................................................................................................

±

5%

Flow Rate Range .................................................................................................................................... 0.25 - 27 GPM
Gallon Range .......................................................................................................................................... 20 - 50,000

DIMENSIONS

Drain Line ............................................................................................................................................... 3/4” or 1” NPT
Brine Line ................................................................................................................................................ 3/8” Poly Tube
Electrical Current Draw and Voltage ....................................................................................................... 0.5A 110v

Compatible with the following regenerants or chemicals:  Sodium chloride, potassium permanganate, sodium bisulfite, sodium hydroxide,

hydroxide, hydrochloric acid, chlorine and chloramines.

GENERAL SPECIFICATIONS

All manuals and user guides at all-guides.com

Содержание Economical Water Conditioning System Series H-100

Страница 1: ...05 Manufactured by HELLENBRAND INC 404 Moravian Valley Road Waunakee Wisconsin 53597 Phone 608 849 3050 Fax 608 849 7398 Web www hellenbrand com Email info hellenbrand com All manuals and user guides...

Страница 2: ...g your water softener please contact the dealer who installed this system TABLE OF CONTENTS Job Specification Sheet Page 2 Operating Conditions 2 Soft Water Basics 3 Frequenty Asked Questions 3 Pre In...

Страница 3: ...for buildup of insoluble materials It is recommended to periodically clean the salt keeper no matter what kind of salt you are using See page 9 miscellaneous 2 for details on cleaning REMEMBER Salt is...

Страница 4: ...s built up heavily with lime and or iron must be replaced If piping is blocked with iron additional equipment must be installed ahead of the water conditioner to correct the problem Drain Line The con...

Страница 5: ...o connecting the drain line flow control fitting Leave at least 6 between the drain line control fitting and solder joints when soldering pipes that are connected on the drain line control fitting Fai...

Страница 6: ...starts coming out of the drain line open the by pass inlet valve all the way and allow to run out the drain until water clears Then slowly place the by pass into the normal operation mode by opening t...

Страница 7: ...it Installer Displays Settings Step 3 Day Override This sets the number of days between regenerations If value set to oFF regeneration initiation is based solely on gallons used If value is set as a n...

Страница 8: ...TODAY will flash on the display to indicate that the system will regenerate at the preset delayed regeneration time If you pressed the REGEN button in error pressing the button again will cancel the r...

Страница 9: ...uns downward and is unobstructed When brine water quits running at the drain be sure to leave the drain valve open until you start the system up again 5 At this time the salt keeper has very little wa...

Страница 10: ...en main or regenerant piston G Replace main or regenerant piston 3 Control valve does not regenerate A Transformer unplugged A Connect transformer automaticallly when REGEN button B No electric power...

Страница 11: ...er ahead of softener C Resin bed mushing due to high amount C Rebed softener Install dechlorinaton system of oxidizers in water supply chlorine 14 Iron in softened water A Iron has fouled resin bed A...

Страница 12: ...y 18x40 Blue 1 3 S75 1 c Brine Tank Assy 24x41 Black 1 3 531100302221 3 d Brine Tank Assy 24x50 Black 1 3 551100302221 3 7 3 8 x 6 Brine Line 1 2 H1023 06 8a 18x33 Brine Tank Tank Blue 1 2 1833BL b 18...

Страница 13: ...the software version ex 154 and then reset the valve to the service position Do not use vaseline oils other hydrocarbon lubricants or spray silicone anywhere A silicon lubricant may be used on black o...

Страница 14: ...washes injector plugs are located in both holes The nuts and caps are designed to be unscrewed or tightened by hand or with the special plastic wrench If necessary a pliers can be used to unscrew the...

Страница 15: ...pe wrench to tighten or loosen nuts or caps Do not place screwdriver in slots on caps and or tap with a hammer Do not use pipe dope or other sealants on threads Teflon tape must be used on threads of...

Страница 16: ...ts and caps are designed to be unscrewed or tightened by hand or with the special plastic wrench If necessary a pliers can be used to unscrew the nut or cap Do not use a pipe wrench to tighten or loos...

Страница 17: ...1 15 V3151 Nut 1 Quick Connect 2 2 15 V3150 Split Ring 2 3 15 V3105 O Ring 215 2 4 15 V3188 01 Fitting 3 4 Brass Sweat 2 1 4 15 V3007 03 Fitting 3 4 Brass Sweat Asy 1 QTY ITEM NO ORDER NO DESCRIPTION...

Страница 18: ...060 28 060 42 090 56 120 84 180 112 240 140 300 168 360 High Salting 24 230 32 310 32 310 48 460 64 620 96 930 129 240 161 550 193 860 Water Usage U S Gallons Normal Backwash Longer Backwash High Max...

Страница 19: ...timated Regeneration occurs at the next Regen Set Time when gallons capacity reaches 0 or the specified number of days between regenerations is reached AUTO On 0 oFF Reserve capacity not automatically...

Страница 20: ...E ARE EXPRESSLY LIMITED TO A TERM OF TWO 2 YEARS SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU As a manufacturer we do not kno...

Отзывы: