TROUBLE SHOOTING

PROBLEM

CAUSE

CORRECTION

8. Loss of resin.

A. Backwash controller missing.

A. Install backwash controller.

B. Faulty distributor tube assembly.

B. Check distributor tube assembly for cracks or holes.

C. Air in water supply system.

C. 1. Check for leaks in brine lines, fittings, or air check.

     Repair or replace.
2. Install upper distributor.
3. Ensure that water supply system has an air

eliminator.

9. Softener delivers salt water.

A. Low water pressure.

A. Check incoming water pressure - Must remain at

minimum of 25 psi.

B. Excessive water in brine tank.

B. See problem #10.

C. Wrong size injector.

C. Install correct injector.

10. Excessive water in brine tank.

A. Plugged injector.

A. Remove injector and clean ports.

B. Faulty piston assembly.

B. Replace piston assembly.

C. Plugged or kinked drain line.

C. Inspect drain line for kinks or plugging.

D. Backwash flow controller closed off.

D. Check backwash flow controller.

E. Defective brine line flow control.

E. Replace brine refill flow control.

11. Softener fails to draw brine.

A. Injector is plugged.

A. Remove injector and clean ports.

B. Faulty piston assembly.

B. Check piston assembly.

C. Brine line connection leak.

C. Inspect brine line during refill cycle for leaks.

D. Drain line plugged creating excess back pressure.

D. Inspect drain line for blockage.

E. Drain line too long or too high

E. Refer to drain line specifications.

F.

Low inlet pressure.

F.

Increase inlet pressure to a minimum of 25 psi.

12. Continuous flow to drain.

A. Piston assembly failure.

A. Replace piston assembly.

B. Motor failure.

B. Replace motor.

G. Circuit board failure.

G. Replace circuit board.

13. Loss of water pressure.

A. Iron build-up in resin.

A. See problem #14.

B. Resin bed fouled with sand or sediment.

B. Rebed  softener  and  install  sediment  filter  ahead

of softener.

C. Resin bed mushing due to high amount

C. Rebed softener.  Install dechlorinaton system

of oxidizers in water supply (chlorine).

14. Iron in softened water.

A. Iron has fouled resin bed.

A. Use iron reducing resin cleaner to cleanse resin bed,

and increase salt dosage or regenerate more
frequently.  Install an Iron Curtain System ahead
of the softener.

B. Iron is not in a soluble state.

B. Test water to determine type of iron, install iron

reduction system.

C. Prefilter failure.

C. Check prefilter.

D. Iron level excessive.

D. Install iron reduction system.

E. Control fails to regenerate.

E. See problem #4.

15. Control does not display time of day

A. Transformer unplugged

A. Connect power

B. No electric power at outlet

B. Repair outlet or use working outlet

C. Defective transformer

C. Replace transformer

D. Defective PC board

D. Replace PC board

16. Control does not display correct

A. Switched outlet

A. Use uniterrupted outlet

time of day

B. Power outage

B. Reset time of day

C. Defective PC board

C. Replace PC board

17. No “softening” or “filtering” display

A. Bypass valve in bypass position

A. Put bypass valve in service position

when water is flowing

B. Meter connection disconnected

B. Connect meter to PC board

C. Restricted/stalled meter turbine

C. Remove meter and check for rotation, clean

foreign material

D. Defective meter

D. Replace meter

E. Defective PC board

E. Replace PC board

18. Control valve regenerates at

A. Power outages

A. Reset control valve to correct time of day

wrong time of day

B. Time of day not set correctly

B. Reset to correct time of day

C. Time of regeneration incorrect

C. Reset regeneration time

D. Control valve set at “on 0”

D. Check control valve set-up procedure

(immediate regeneration)

regeneration time option (see table 6, page 19)

E. Control valve set at on 0

E. Check control valve set-up procedure

regeneration time option (see table 6, page 19)

All manuals and user guides at all-guides.com

all-guides.com

Содержание Economical Water Conditioning System Series H-100

Страница 1: ...05 Manufactured by HELLENBRAND INC 404 Moravian Valley Road Waunakee Wisconsin 53597 Phone 608 849 3050 Fax 608 849 7398 Web www hellenbrand com Email info hellenbrand com All manuals and user guides...

Страница 2: ...g your water softener please contact the dealer who installed this system TABLE OF CONTENTS Job Specification Sheet Page 2 Operating Conditions 2 Soft Water Basics 3 Frequenty Asked Questions 3 Pre In...

Страница 3: ...for buildup of insoluble materials It is recommended to periodically clean the salt keeper no matter what kind of salt you are using See page 9 miscellaneous 2 for details on cleaning REMEMBER Salt is...

Страница 4: ...s built up heavily with lime and or iron must be replaced If piping is blocked with iron additional equipment must be installed ahead of the water conditioner to correct the problem Drain Line The con...

Страница 5: ...o connecting the drain line flow control fitting Leave at least 6 between the drain line control fitting and solder joints when soldering pipes that are connected on the drain line control fitting Fai...

Страница 6: ...starts coming out of the drain line open the by pass inlet valve all the way and allow to run out the drain until water clears Then slowly place the by pass into the normal operation mode by opening t...

Страница 7: ...it Installer Displays Settings Step 3 Day Override This sets the number of days between regenerations If value set to oFF regeneration initiation is based solely on gallons used If value is set as a n...

Страница 8: ...TODAY will flash on the display to indicate that the system will regenerate at the preset delayed regeneration time If you pressed the REGEN button in error pressing the button again will cancel the r...

Страница 9: ...uns downward and is unobstructed When brine water quits running at the drain be sure to leave the drain valve open until you start the system up again 5 At this time the salt keeper has very little wa...

Страница 10: ...en main or regenerant piston G Replace main or regenerant piston 3 Control valve does not regenerate A Transformer unplugged A Connect transformer automaticallly when REGEN button B No electric power...

Страница 11: ...er ahead of softener C Resin bed mushing due to high amount C Rebed softener Install dechlorinaton system of oxidizers in water supply chlorine 14 Iron in softened water A Iron has fouled resin bed A...

Страница 12: ...y 18x40 Blue 1 3 S75 1 c Brine Tank Assy 24x41 Black 1 3 531100302221 3 d Brine Tank Assy 24x50 Black 1 3 551100302221 3 7 3 8 x 6 Brine Line 1 2 H1023 06 8a 18x33 Brine Tank Tank Blue 1 2 1833BL b 18...

Страница 13: ...the software version ex 154 and then reset the valve to the service position Do not use vaseline oils other hydrocarbon lubricants or spray silicone anywhere A silicon lubricant may be used on black o...

Страница 14: ...washes injector plugs are located in both holes The nuts and caps are designed to be unscrewed or tightened by hand or with the special plastic wrench If necessary a pliers can be used to unscrew the...

Страница 15: ...pe wrench to tighten or loosen nuts or caps Do not place screwdriver in slots on caps and or tap with a hammer Do not use pipe dope or other sealants on threads Teflon tape must be used on threads of...

Страница 16: ...ts and caps are designed to be unscrewed or tightened by hand or with the special plastic wrench If necessary a pliers can be used to unscrew the nut or cap Do not use a pipe wrench to tighten or loos...

Страница 17: ...1 15 V3151 Nut 1 Quick Connect 2 2 15 V3150 Split Ring 2 3 15 V3105 O Ring 215 2 4 15 V3188 01 Fitting 3 4 Brass Sweat 2 1 4 15 V3007 03 Fitting 3 4 Brass Sweat Asy 1 QTY ITEM NO ORDER NO DESCRIPTION...

Страница 18: ...060 28 060 42 090 56 120 84 180 112 240 140 300 168 360 High Salting 24 230 32 310 32 310 48 460 64 620 96 930 129 240 161 550 193 860 Water Usage U S Gallons Normal Backwash Longer Backwash High Max...

Страница 19: ...timated Regeneration occurs at the next Regen Set Time when gallons capacity reaches 0 or the specified number of days between regenerations is reached AUTO On 0 oFF Reserve capacity not automatically...

Страница 20: ...E ARE EXPRESSLY LIMITED TO A TERM OF TWO 2 YEARS SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU As a manufacturer we do not kno...

Отзывы: