- 1 -
Components supplied with the unit for site fitting
(See also page 2 for component list)
* Multibloc valve, includes pressure reducing valve, line strainer, balanced cold water take off,
(for shower or bidet only)
check and expansion valve.
* Tundish
* 3/4’’ x 22mm Elbow / Drain Cock
* Motorised valve
* Expansion vessel.
Components factory fitted
* Immersion heater(s)
* Thermostats / thermal cut-out
* Temperature and pressure relief valve.
Installation details
The OSO unvented unit is designed for use with supply pressure up to 10 bar. For pressures
over 10 bar an additional pressure reducing valve must be fitted in the supply pipe to the unit.
PRODUCT REF.
120 150 180 210 250 300
HEIGHT
770 915 1060 1200 1450 1660
DIAMETER
580 580 580 580 580 580
WEIGHT
EMPTY 30,5 38,0 40,5 44,5 51,5 56,0
MAX WEIGHT FULL
150
181
212
244
299
347
COIL SURFACE AREA - M²
0.4 0.8 0.8 0.8 0.8 0.8
142049-02 09-2015
This cylinder is manufactured and approved in accordance with EN 12897:2006.
This manual gives detailed advice for installation and should be read carefully
prior to fitting any unvented unit.
This OSO cylinder must be installed by a competent person and be installed in
compliance with the OSO Installation and Maintenance Instructions, all current
legislation, codes of practice and regulations governing the installation of unvented
hot water cylinders in force at the date of installation.
Health and Safety
Manual Handling Operations Regulations 1992 defines manual handling as: “any
transporting or supporting of a load (including the lifting, putting down, pushing,
pulling, carrying or moving thereof) by hand or bodily force”. The Regulations set no
specific requirements such as weight limits. However common sense still has to be
used based on an ergonomic approach for each individual.
DIMENSIONS AND WEIGHTS TABLE 1
PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION
INSTALLATION MANUAL
ECOLINE