Eradicator Gen II O
3
Manual Supplement
Install & Service Guide
7
Copyright ©2021 Aqua Systems, All Rights Reserved • 404 Moravian Valley Road, Waunakee, WI 53597
Gen II O
3
with Ozone
Tygon
Tubing
Ozone Resistant
Check Valve
Ozone Resistant
Check Valve
Figure c
Locking Collar
The ozone resistant check valve
is pre-inserted into the 3/8" Tygon
tubing.
Tygon tubing is inserted and
seated in the push connect
fitting.
Firmly insert the black tubing
(
figure b
) from the EOG II
into the push connect elbow
(
figure a
). Be sure the tubing
has fully seated.
If the tubing needs to be
removed from the elbow,
press the locking collar (
figure
c
) flush with the fitting and pull
out the tubing.
Installation
Ozone Resistant Air Draw Check Valve Assembly
Tubing to Elbow
Installation
Figure a
Figure b
These components should only be serviced by qualified
technicians.
Note:
There is no check valve in the bottom of
the brine fitting like is found in standard
Eradicator. Brine flow control is also re
-
moved for operating with ozone.
Note: