Overview
The Eradicator Gen II O3, with ozone, is a breakthrough in chemical free filtration. The ozone is made
from oxygen, then converts back to oxygen after its effective function. Ozone expedites the oxidation
in the Eradicator’s aeration process. The ozone is made from ambient air that is pulled into the control
during the draw cycle. A 12 volt DC generator creates electrical arcing technology, inside of a sealed
tube, known as Corona Discharge (CD). When the air is exposed to the arcing electrical current, the
Oxygen in the air (O
2
) converts to Ozone (O
3
). Once the ozone has done its job inside the filtration sys
-
tem, it converts back to Oxygen (O
2
), leaving the effluent water from the filter refreshingly oxygenated.
The ozone generated in the Eradicator’s aeration process works as a Super Oxygen source. This
technique provides much more oxygen for the oxidation of iron and sulfur, and for restoring oxygen
sites on the media’s surface, than ambient air alone.
The ozone is generated from the auxiliary circuit board that is mounted inside of the Gen II EOG II
cover. This Eradicator O3 is operated by a single power supply in which the O
3
generator is activated
by the AQx relay function. The programming to activate the ozone generator is in the Eradicator elec-
tronics package. The programming for this function should only be accessed by a qualified technician.
Gen II O
3
with Ozone
Note:
The Gen II AQx control is programmed to activate the ozone generator. The ozone gen-
erator will not turn on if the control is fast-stepped through cycles by using the REGEN
button. You must wait for the activation based on the number of minutes from the start
of the cycle.
This issue is very different from standard Eradicator setup. The installer / service techni-