14. Other Options
14.1) Motorized Diverting Valve Switching Time
Set how many minutes as switching time of the motorized diverting valve spending on switching
the water flow fully between DHW and Heating/Cooling circuit.
Note
:
This
parameter
must
comply
with
the
motorized
diverting
valve. Otherwise
unit may not
be
able
to
work
due
to
not enough water flow rate.
14.2) Power On Time for Motorized Diverting Valve
Set
how
long
the
motorized
diverting
valve
should
be
powered
,
for
switching
the
water flow
fully
between
DHW
and
Heating
/
Cooling
circuit
.
14.3) Refrigerant Recycle
This
function can be used by installers to recycle the refrigerant in the complete system into condensing
unit for service purpose. When it is activated, unit will be forced to work in cooling operation for some
time, to push all refrigerant back to condensing unit.
14.4) Control Panel Backlight
14.5) Exit System
Exit
from
unit
program
and
returns
to
WINCE
operation
system
.
This
is
used
for
software
updating
.
Set
the
backlight
touch
screen
operation
panel
to
be
"
Always on
"
or
how
long
before
it
becomes
off
for
energy
saving
.