4. DHW Storage
Sanitary Hot Water Storage Function
After showers, house usually needs only medium temperature sanitary hot water in day time. This
function is used to store high temperature sanitary hot water in low demand time (mid-night, or day
time of working days), and reheat the water to medium temperature out of this time period.
4.01 Sanitary Hot Water Storage Function
Turn ON/OFF this function.
4.02 Sanitary Hot Water Storage Timer
Set a working time period for this function, and the unit starts to work towards sanitary hot water set
temperature in parameter 3.01 within the set time range.
Different time periods for every day in a week can be set.
4.03 Reheating Function
Turn ON/OFF reheat function.
4.04 Reheating Function Timer
Set a working time period for reheat function
,
and within this time period, unit will work with
a lower
set value for DHW (value set in parameter 4.05). Different time period for every day in a
week can be set
.