Installation Preparation
Suprasetter A52/A75 – Installation
Provision of a Power Cable
For connection of the Suprasetter, the sales department can also order a power cable, either a EU or
US version, as a separate accessory. Its insulation is already stripped off to the correct length on the
machine side but the cable does
not
have a connector for the service tap. If a connector is to be used
at the service tap instead of a termination, this connector must be procured locally and connected in
keeping with regulations.
A three-wire power cable must be procured locally if no power cable was included in the shipment
for connection of the Suprasetter.
Power cable for Europe
: 3-wire, 2.5 mm², e.g. H07-RN-F, length 8 m, sheath: rubber. Permanent
connection to the service tap or industrial connector as per IEC 309, type B, CEE 16A–6h (50 Hz) or
16A–9h (60 Hz).
Power cable for USA
: 3-wire, 14AWG, AWM, min. 300 V, min. 80°C, SJT, VW1,
sheath: PVC or rubber. Length: 8 m when permanently connected, length: max 4.5 m when an L6–15P
connector is fitted.
Note:
The outer diameter of the cable must not exceed 13 mm.
Plate Material
Depending on the printing plate manufacturer and the used plate material, thermal plates are also
sensitive to light. The quality of some plates may degrade even after a few minutes due to the UV por-
tion of white light illumination in the room. Note the information on the packaging of the printing
plates. If necessary, you can contact the plate manufacturers for their specifications.
Observe the following items when handling printing plates:
• Plate edges can be sharp - wear gloves!
• Never touch the emulsion side with your bare hands.
• The surface is sensitive to scratches.
NOTICE
Risk of corrosion
Without protective foil condensation water would form on plain machine parts
and cause corrosion.
In order to prevent this the protective foil must not be immediately removed once
the machine has been transported to the installation site. The protective foil must
be removed only when the machine has adapted to the ambient temperature.
i
i
Содержание Suprasetter A52
Страница 6: ......
Страница 24: ...Safety 22 Fig 24 Filter replacement Fig 13 4 On the filter unit ...
Страница 26: ...Safety 24 Fig 26 Warning sign copy template ...
Страница 36: ...Installation Preparation 34 Pallet Installation Instructions ...
Страница 60: ...Installation 58 Fig 51 Power cable strain relief Tighten the strain relief for the power cable Fig 51 1 ...
Страница 82: ...Technical Data 80 Resolution 1000 pixels cm 2540 dpi Type Value Comment ...
Страница 84: ......
Страница 85: ......