Safety
Suprasetter A52/A75 – Installation
Additional Protective Conductor Terminal
Fig. 1 Additional Protective Conductor Terminal
Fig. 2 PE terminal
Since the leakage current is >10 mA, it is manda-
tory to connect the protective earth (PE) wire in
the power cable and the additional protective con-
ductor cable. A separate PE cable (green-and-yel-
low or only green) with a cable cross-section of at
least 6 mm² must be routed parallel to the power
cable.
This cable (8 m) is included in the Suprasetter
shipment. On the Suprasetter it must be con-
nected on the left to the rear brace (Fig. Fig. 1).
At the service tap, it must be connected to a sepa-
rate PE terminal (Fig. 2/1). In addition, you must
make sure that the PE is routed further in the ser-
vice tap with a cable cross section of at least
10 mm².
Содержание Suprasetter A52
Страница 6: ......
Страница 24: ...Safety 22 Fig 24 Filter replacement Fig 13 4 On the filter unit ...
Страница 26: ...Safety 24 Fig 26 Warning sign copy template ...
Страница 36: ...Installation Preparation 34 Pallet Installation Instructions ...
Страница 60: ...Installation 58 Fig 51 Power cable strain relief Tighten the strain relief for the power cable Fig 51 1 ...
Страница 82: ...Technical Data 80 Resolution 1000 pixels cm 2540 dpi Type Value Comment ...
Страница 84: ......
Страница 85: ......