Safety
For the operating company of a print shop, it is important that the exposure limits regarding breath-
able air in the work area (where the platesetter is located) are adhered to. The air exchange must be
arranged in such a way that the measured dust particles are regularly below the exposure limit val-
ues. In accordance with the state of the art, this can be achieved with an 8 to 10 air change rate per
hour. If this is not the case at the installation site, the operating company should install an additional
exhaust system.
When installing the machine, pay attention to the information in the "
" and "
" chapters.
In order to provide proper ventilation, ensure that there is sufficient distance between the machine
and the wall or between the machine sides and other equipment when the equipment is installed.
The machine
• should not be installed in the proximity of air conditioning facilities,
• must be protected against direct sunlight or spotlights fitted in the room,
• must be protected against moisture.
In order to meet radio interference suppression requirements, only screened data cables may be
used.
Because the installation site must have clean conditions, the Suprasetter may not be operated in sites
where paper is being printed or paper finishing devices are running.
The required ambient conditions (see Technical Data chapter) must be observed for at least 12 hours
after power-off so that the Suprasetter is not damaged by condensation.
Power Supply
The Suprasetter is connected to the inhouse power supply either permanently with terminal block KL1
and the 3-wire power cable or with a 3-pin industrial connector that must be designed for connection
to 200 - 240 V 50/60 Hz. The respective national regulations must be observed if power cables are
used that were not supplied by Heidelberger Druckmaschinen AG or if connectors are modified. The
outside diameter of the power cable must not exceed 13 mm.
In the EU and in the extended area of validity of IEC 60204-1 (for latest version, see Table
), the minimum cross section of the protective conductor must be 10 mm² for a leakage current
of 10 mA and higher. The leakage current of this Suprasetter is up to 30 mA.
Содержание Suprasetter A52
Страница 6: ......
Страница 24: ...Safety 22 Fig 24 Filter replacement Fig 13 4 On the filter unit ...
Страница 26: ...Safety 24 Fig 26 Warning sign copy template ...
Страница 36: ...Installation Preparation 34 Pallet Installation Instructions ...
Страница 60: ...Installation 58 Fig 51 Power cable strain relief Tighten the strain relief for the power cable Fig 51 1 ...
Страница 82: ...Technical Data 80 Resolution 1000 pixels cm 2540 dpi Type Value Comment ...
Страница 84: ......
Страница 85: ......