HeatStar HS125KT Скачать руководство пользователя страница 3

Kerosene Forced Air Heater

Operating Instructions and Owner’s Manual

3

CAUTION: CSA certified for use with only No. 1-K kerosene fuel.

Model  HS50K  HS75KT  HS125KT HS175KT  HS210KT

Burn Rate: 

50,000 Btu/hr (14.7 kW)  75,000 Btu/hr (22 kW) 

125,000 Btu/hr (37 kW) 

175,000 Btu/hr (51 kW) 

210,000 Btu/hr (61.5 kW)

Fuel Rate: 

0.37 gal/hr (1.4 L/hr) 

0.55 gal/hr (2.1 L/hr) 

0.96 gal./hr (3.5 L/hr)  

1.3 gal/hr (5.0 L/hr) 

1.6 gal/hr (6.0 L/hr)

Electrical Input: 

115V, 60Hz, 3.5a 

115V, 60Hz, 4a 

115V, 60Hz, 5.5a 

115V, 60Hz, 5.5a 

115V, 60Hz, 5.5a

Line Protection: 

10 amps 

10 amps 

20 amps 

20 amps 

20 amps

Min. Operating Voltage:  110V 

110V 

110V 

110V 

110V

Pressure Setting: 

3.8 psig (26.2 kPa) 

4.2 psig (29 kPa) 

5.1 psig (35.2 kPa) 

6.8 psig (46.9 kPa) 

8.2 psig (56.5 kPa)

Max. Outlet Temperature:  1300

o

F (704

o

C) 1300

o

F (704

o

C) 1300

o

F (704

o

C) 1300

o

F (704

o

C) 1300

o

F (704

o

C)

Fuel Tank Capacity: 

4 gallons (15.1 L) 

6 gallons (22.7 L) 

14 gallons (53 L) 

14 gallons (53 L) 

14 gallons (53 L)

Ignition: 

Direct Spark, Continuous   Direct Spark, Continuous  Direct Spark, Continuous  Direct Spark, Continuous 

Direct Spark, Continuous

Spark Generator: 

Igniter 13 kV, 10ma 

Igniter 13 kV, 10ma 

Igniter 13 kV, 10ma 

Igniter 13 kV, 10ma 

Igniter 13 kV, 10ma

Primary Safety Control:  Solid State Control 

Solid State Control 

Solid State Control 

Solid State Control 

Solid State Control

Certification: 

 

 

 

 

 

 

 

 

SPECIFICATIONS

OPERATING PRECAUTIONS

This is a kerosene, direct-fired, forced air heater. It’s intended use 
is primarily temporary heating of buildings under construction, 
alteration or repair.
Direct-Fired means that all of the combustion products enter the 
heated space. Even though this heater operates very close to 100 
percent combustion efficiency, it still produces small amounts of 
carbon monoxide. Carbon monoxide (called CO) is toxic. CO can 
build up in a heated space and failure to provide adequate ventila-
tion could result in death. The symptoms of inadequate ventilation 
are:
• 

headache 

• 

dizziness

• 

burning eyes and nose 

• 

nausea

• 

dry mouth or sore throat

Be sure to follow advice about ventilation in the Safety Precautions 
section.
Forced Air means that a blower or fan pushes the air through the 
heater. Proper combustion depends upon this air flow; therefore, 
the heater must not be revised, modified or operated with parts 
removed or missing. Likewise, safety systems must not be circum-
vented or modified in order to operate the heater.
When the heater is to be operated in the presence of other people 
the user is responsible for properly acquainting those present 
with the safety precautions and instructions, and of the hazards 
involved.

SAFETY PRECAUTIONS

1.  Recommended for use with No.1-K kerosene fuel. Factory 

tested for use with No.2-K kerosene, No.1 or No.2 Diesel, 
No.1 or No.2 fuel oil or JP8 Jet A fuel and these fuels may 
be used as well. Never use gasoline, oil drained from crank 
cases, naphtha, paint thinners, alcohol or any other highly 
flammable fuels.

2.   Check the heater thoroughly for damage. DO NOT operate a 

damaged heater.

3.  DO NOT modify the heater or operate a heater which has 

been modified from its original condition.

4.  For indoor use only. Not for use where exposed to weather.
5.  Use in well ventilated areas, provide at least 2 sq. ft. (0.19 

sq. m.) of opening near the floor and 2 sq. ft. (0.19 sq. m.) 
near the ceiling directly to outdoors. Increase air openings as 
marked for each additional heater.

6.  Always keep combustibles, like paper and wood at least 

8 ft. (2.4 m) from the heater outlet and 3 ft. (1.0 m) from 
the top, sides and inlet. Locate 10 ft. (3.0 m) from canvas 
or plastic coverings and secure them to prevent flapping 
movement. 

7.  Caution: Due to the high surface and exhaust temperatures, 

adults and children must observe clearances to avoid burns 
or clothing ignition. Do Not Touch. Keep children, clothing, 
and combustible away.

8.  Install the heater such that it is not directly exposed to water 

spray, rain and / or water.

9.  Never use in areas normally for habitation and /or where 

children may be present.

10.  Operate only on a stable, level surface. (HS50K & HS75KT – 

See wood floor warning).

11.  Do not use with duct work. Do not restrict inlet or exit.
12.  Use only with electrical power specified. The electrical 

connection and grounding must comply with National 
Electrical Code – ANSI/NFPA 70 (USA) and CSA C22.1 
Canadian Electrical Code, Part 1 (Canada).

13.  Use only a properly grounded 3-prong receptacle or 

extension cord.

14.  Do not move, handle, or service while hot or in operation.
15.  Use only in accordance with local, state (provincial) or 

national requirements, ordinances and codes.

OPERATING INSTRUCTIONS

UNPACKING

1.  Remove heater from carton.
2.  Remove all protective material which may have been applied 

to the heater for shipment.

3.  Check the heater for possible shipping damage. If any 

damage is found immediately contact the manufacturer at 
800-251-0001.

ASSEMBLY 

(For 125,000, 175,000 and 210,000 BTU/hr models 

only, see figure 1, page 8.)
Wheels and handles are found in the shipping carton along with 
mounting hardware. The wheels, axle and mounting hardware are 
in a package. Tools required are a 5/16” nut driver, 3/8” open or 
adjustable wrench and standard pliers.

1.  Assemble the wheels onto the wheel support frame as 

follows:

Содержание HS125KT

Страница 1: ...ity of this or any other appliance Service must be performed by a qualified service agency This is an unvented portable heater It uses air oxygen from the area in which it is used Adequate combustion...

Страница 2: ...DAMAGE FROM HAZARDS OF FIRE EXPLOSION BURN ASPHYXIATION CARBON MONOX IDE POISONING AND OR ELECTRICAL SHOCK ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATE...

Страница 3: ...with the safety precautions and instructions and of the hazards involved SAFETY PRECAUTIONS 1 Recommended for use with No 1 K kerosene fuel Factory tested for use with No 2 K kerosene No 1 or No 2 Di...

Страница 4: ...SION CORD REQUIREMENTS Up to 100 30 5m use 16 awg conductor 101 200 30 5 61 0m use 14 awg conductor For all models In cold weather below 10 F starting may be improved by holding a finger over the vent...

Страница 5: ...If this occurs replace the fuel nozzle 5 FUEL TANK Clean twice a season during frequently used periods clean twice a month Drain and flush the fuel tank with clean fuel oil ANNUAL SCHEDULE 1 AIR OUTP...

Страница 6: ...n electrode probes 2 3 3 mm 4 Still no spark replace igniter assembly 5 Replace oil flame control assembly Abnormal Motor Operation 1 Motor speed too low Motor should operate at 3450rpm Motor overheat...

Страница 7: ...ked A heater which is not working right must be repaired but only by a trained experienced service person 18AWG BLUE THERMOSTAT 18AWG PURPLE COM1 I2 I1 M2 M1 L N 18AWG PURPLE 18AWG GRN 18AWG BLK 18AWG...

Страница 8: ...r office hours are 8 00 AM 5 00 PM EST Monday through Friday Please include the model number date of purchase and description of problem in all communication LIMITED WARRANTY Enerco Technical Products...

Страница 9: ...un fournisseur de services d entretien qualifi Cet appareil de chauffage portatif n est pas ventil Il utilise l oxyg ne de l air ambiant Une circulation d air ad quate doit tre assur e pour la combust...

Страница 10: ...LURE D ASPHYXIE D INTOXICATION AU MONOXYDE DE CARBONE OU D LECTROCUTION SEULES LES PERSONNES APTES COMPRENDRE ET RESPECTER LES INSTRUCTIONS DEVRAIENT UTILISER OU EFFECTUER L ENTRETIEN DE CET APPAREIL...

Страница 11: ...e chauffage doit fonctionner en pr sence d autres personnes l utilisateur est responsable d informer ces derni res des instructions et pr cautions li es la s curit et de les avertir des dangers inh re...

Страница 12: ...s des p riodes d entreposage prolong es enlevez en la condensation 4 Placez l appareil de chauffage une distance s curitaire des mat riaux combustibles Les mod les 50 et 75 ne sont pas con us pour tre...

Страница 13: ...es avec un chiffon sec et propre Inspectez ces endroits pour vous assurer que toute mati re trang re a t enlev e particuli rement autour du br leur et de la zone de combustion 3 CELLULE AU CADMIUM Net...

Страница 14: ...e 4 2 V rifiez le c blage vers l allumeur selon le sch ma de c blage du pr sent guide 3 V rifiez l cart entre les pointes d lectrode 2 3 3 mm 4 S il n y a toujours pas d tincelle remplacez l allumeur...

Страница 15: ...r Si l appareil de chauffage ne fonctionne pas correctement il doit tre r par uniquement par un technicien qualifi COM1 I2 I1 M2 M1 L N 1 3 2 H2 H1 VRT AWG 18 JAUNE AWG 18 NOIR AWG 18 JAUNE AWG 18 BLE...

Страница 16: ...10 Kerosene Forced Air Heater Operating Instructions and Owner s Manual PAGE LEFT INTENTIONALLY BLANK...

Страница 17: ...enerco com Nos heures d ouverture sont de 8 h 00 17 h HNE du lundi au vendredi Veuillez indiquer le num ro du mod le la date d achat et la description du probl me dans toutes vos communications avec n...

Страница 18: ...to El mantenimiento debe ser realizado por una agencia de reparaci n calificada Este calentador port til no tiene una fuente propia de ventilaci n Utiliza el aire ox geno del rea en la cual se emplea...

Страница 19: ...O DE INCENDIO EXPLOSI N QUEMADURAS ASFIXIA ENVENENAMIENTO CON MON XIDO DE CARBONO Y O DESCARGAS EL CTRICAS SOLO LAS PERSONAS QUE ENTIENDAN Y PUEDAN SEGUIR LAS INSTRUCCIONES DEBEN USAR O MANTENER ESTE...

Страница 20: ...as o la ignici n de su ropa No tocar Mantener alejado de los ni os la ropa y el combustible 8 Instale el calentador de forma tal que no est directamente expuesto a salpicaduras de agua lluvia o agua 9...

Страница 21: ...alentador realizar ciclos de encendido apagado a medida que se necesite calor REQUISITOS DEL CABLE DE EXTENSI N hasta 100 30 5 m use un conductor CAE 16 101 200 30 5 61 0 m use un conductor CAE 14 Par...

Страница 22: ...tible y aire y olor y humo en exceso Si esto sucede reemplace el pico de combustible 5 TANQUE DE COMBUSTIBLE L mpielo dos veces por temporada durante per odos de uso frecuente l mpielo dos veces por m...

Страница 23: ...iagrama Verifique los requisitos en la p gina 4 2 Verifique el cableado al encendedor seg n el esquema de cableado en el manual 3 Verifique el espacio entre las sondas de electrodos 2 3 3 mm 4 A n no...

Страница 24: ...rectamente debe ser reparado pero solo por un t cnico de mantenimiento capacitado y experimentado I2 I1 M2 M1 L N 1 3 2 H2 H1 18 AWG VERDE 18 AWG NEGRO 18 AWG BLANCO LLAVE DE ENCENDIDO JUEGO DE CABLES...

Страница 25: ...10 Kerosene Forced Air Heater Operating Instructions and Owner s Manual PAGE LEFT INTENTIONALLY BLANK...

Страница 26: ...ajo es de 8 00 a m a 5 00 p m hora del este de lunes a viernes Incluya el n mero de modelo la fecha de compra y la descripci n del problema en todas sus comunicaciones GARANT A LIMITADA Enerco Technic...

Отзывы: