HeatStar HS125KT Скачать руководство пользователя страница 2

2

Kerosene Forced Air Heater

Operating Instructions and Owner’s Manual

CONTENTS

WARNINGS .................................................................................

2

HEATER SPECIFICATIONS

 ............................................................. 3

OPERATING PRECAUTIONS

 .......................................................... 3

SAFETY PRECAUTIONS

 ................................................................ 3

OPERATING INSTRUCTIONS

 ........................................................ 3

MAINTENANCE, STORAGE AND SERVICE  ................................... 4

TROUBLE SHOOTING

 .................................................................. 6

WIRING DIAGRAM ......................................................................

7

PARTS LIST

 ..................................................................................

8

EXPLODED VIEW

 .........................................................................

9

WARRANTY

 ...............................................................................10

INSTRUCTIONS FOR ORDERING PARTS

 .......................................10

WARNING: 

•  DO NOT USE GASOLINE, NAPHTHA OR VOLATILE 

FUELS.

•  STOP HEATER BEFORE ADDING FUELS.
•  ALWAYS FILL OUTDOORS AWAY FROM OPEN FLAME
•  DO NOT USE EXTERNAL FUEL SOURCE.
•  DO NOT OPERATE HEATER WHERE FLAMMABLE 

LIQUIDS OR VAPORS MAY BE PRESENT.

•  DO NOT START HEATER WHEN CHAMBER IS HOT
•  DO NOT START HEATER WHEN EXCESS FUEL HAS 

ACCUMULATED IN THE CHAMBER.

•  DO NOT PLACE COOKING UTENSILS ON TOP OF 

THE HEATER.

•  PLUG ELECTRICAL CORD INTO A PROPERLY GROUN-

DED THREE-PRONG RECEPTACLE.

HS50K & HS75KT WARNING:

Not suitable for use on wood floors or other 
combustible materials. When used the heater 
should rest on a suitable insulating material at 
least 1 inch thick and extending 3 feet or more 
beyond the heater in all directions.

GENERAL HAZARD WARNING:

  FAILURE TO COMPLY WITH THE PRECAUTIONS AND 

INSTRUCTIONS PROVIDED WITH THIS HEATER, CAN 
RESULT IN DEATH, SERIOUS BODILY INJURY AND 
PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE, 
EXPLOSION, BURN, ASPHYXIATION, CARBON MONOX-
IDE POISONING, AND/OR ELECTRICAL SHOCK.

 ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW 

THE INSTRUCTIONS SHOULD USE OR SERVICE THIS 

HEATER.

  IF YOU NEED ASSISTANCE OR HEATER INFORMATION 

SUCH AS AN INSTRUCTIONS MANUAL, LABELS, ETC. 
CONTACT THE MANUFACTURER.

WARNING: 

  FIRE, BURN, INHALATION, AND EXPLOSION HAZARD. 

KEEP SOLID COMBUSTIBLES, SUCH AS BUILDING 
MATERIALS, PAPER OR CARDBOARD, A SAFE DISTANCE 
AWAY FROM THE HEATER AS RECOMMENDED BY THE 
INSTRUCTIONS NEVER USE THE HEATER IN SPACES 
WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE 
COMBUSTIBLES, OR PRODUCTS SUCH AS GASOLINE, 
SOLVENTS, PAINT THINNER, DUST PARTICLES OR UN-

KNOWN CHEMICALS.

WARNING: 

 

COMBUSTION BY-PRODUCTS PRODUCED WHEN US-
ING THIS PRODUCT CONTAIN CARBON MONOXIDE, 
A CHEMICAL KNOWN TO THE STATE OF CALIFORNIA 
TO CAUSE CANCER AND BIRTH DEFECTS (OR OTHER 
REPRODUCTIVE HARM).

 

THIS PRODUCT CONTAINS CHEMICALS KNOWN TO 
THE STATE OF CALIFORNIA TO CAUSE CANCER AND 
BIRTH DEFECTS OR OTHER REPRODUCTIVE HARM.

WARNING: 

  NOT FOR HOME OR RECREATIONAL VEHICLE USE

WARNING:

  YOUR SAFETY IS IMPORTANT TO YOU AND TO OTHERS, 

SO PLEASE READ THESE INSTRUCTIONS BEFORE YOU 
OPERATE THIS HEATER.

The State of California requires the following warning:

 WARNING: 

 

CARBON MONOXIDE CAN KILL YOU

 

USING A PORTABLE GAS CAMPING HEATER INSIDE A 
TENT, RV, CAMPER, VEHICLE, SHELTER OR OTHER EN-
CLOSED AREAS CAN PRODUCE DEADLY CARBON MON-

OXIDE

Содержание HS125KT

Страница 1: ...ity of this or any other appliance Service must be performed by a qualified service agency This is an unvented portable heater It uses air oxygen from the area in which it is used Adequate combustion...

Страница 2: ...DAMAGE FROM HAZARDS OF FIRE EXPLOSION BURN ASPHYXIATION CARBON MONOX IDE POISONING AND OR ELECTRICAL SHOCK ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATE...

Страница 3: ...with the safety precautions and instructions and of the hazards involved SAFETY PRECAUTIONS 1 Recommended for use with No 1 K kerosene fuel Factory tested for use with No 2 K kerosene No 1 or No 2 Di...

Страница 4: ...SION CORD REQUIREMENTS Up to 100 30 5m use 16 awg conductor 101 200 30 5 61 0m use 14 awg conductor For all models In cold weather below 10 F starting may be improved by holding a finger over the vent...

Страница 5: ...If this occurs replace the fuel nozzle 5 FUEL TANK Clean twice a season during frequently used periods clean twice a month Drain and flush the fuel tank with clean fuel oil ANNUAL SCHEDULE 1 AIR OUTP...

Страница 6: ...n electrode probes 2 3 3 mm 4 Still no spark replace igniter assembly 5 Replace oil flame control assembly Abnormal Motor Operation 1 Motor speed too low Motor should operate at 3450rpm Motor overheat...

Страница 7: ...ked A heater which is not working right must be repaired but only by a trained experienced service person 18AWG BLUE THERMOSTAT 18AWG PURPLE COM1 I2 I1 M2 M1 L N 18AWG PURPLE 18AWG GRN 18AWG BLK 18AWG...

Страница 8: ...r office hours are 8 00 AM 5 00 PM EST Monday through Friday Please include the model number date of purchase and description of problem in all communication LIMITED WARRANTY Enerco Technical Products...

Страница 9: ...un fournisseur de services d entretien qualifi Cet appareil de chauffage portatif n est pas ventil Il utilise l oxyg ne de l air ambiant Une circulation d air ad quate doit tre assur e pour la combust...

Страница 10: ...LURE D ASPHYXIE D INTOXICATION AU MONOXYDE DE CARBONE OU D LECTROCUTION SEULES LES PERSONNES APTES COMPRENDRE ET RESPECTER LES INSTRUCTIONS DEVRAIENT UTILISER OU EFFECTUER L ENTRETIEN DE CET APPAREIL...

Страница 11: ...e chauffage doit fonctionner en pr sence d autres personnes l utilisateur est responsable d informer ces derni res des instructions et pr cautions li es la s curit et de les avertir des dangers inh re...

Страница 12: ...s des p riodes d entreposage prolong es enlevez en la condensation 4 Placez l appareil de chauffage une distance s curitaire des mat riaux combustibles Les mod les 50 et 75 ne sont pas con us pour tre...

Страница 13: ...es avec un chiffon sec et propre Inspectez ces endroits pour vous assurer que toute mati re trang re a t enlev e particuli rement autour du br leur et de la zone de combustion 3 CELLULE AU CADMIUM Net...

Страница 14: ...e 4 2 V rifiez le c blage vers l allumeur selon le sch ma de c blage du pr sent guide 3 V rifiez l cart entre les pointes d lectrode 2 3 3 mm 4 S il n y a toujours pas d tincelle remplacez l allumeur...

Страница 15: ...r Si l appareil de chauffage ne fonctionne pas correctement il doit tre r par uniquement par un technicien qualifi COM1 I2 I1 M2 M1 L N 1 3 2 H2 H1 VRT AWG 18 JAUNE AWG 18 NOIR AWG 18 JAUNE AWG 18 BLE...

Страница 16: ...10 Kerosene Forced Air Heater Operating Instructions and Owner s Manual PAGE LEFT INTENTIONALLY BLANK...

Страница 17: ...enerco com Nos heures d ouverture sont de 8 h 00 17 h HNE du lundi au vendredi Veuillez indiquer le num ro du mod le la date d achat et la description du probl me dans toutes vos communications avec n...

Страница 18: ...to El mantenimiento debe ser realizado por una agencia de reparaci n calificada Este calentador port til no tiene una fuente propia de ventilaci n Utiliza el aire ox geno del rea en la cual se emplea...

Страница 19: ...O DE INCENDIO EXPLOSI N QUEMADURAS ASFIXIA ENVENENAMIENTO CON MON XIDO DE CARBONO Y O DESCARGAS EL CTRICAS SOLO LAS PERSONAS QUE ENTIENDAN Y PUEDAN SEGUIR LAS INSTRUCCIONES DEBEN USAR O MANTENER ESTE...

Страница 20: ...as o la ignici n de su ropa No tocar Mantener alejado de los ni os la ropa y el combustible 8 Instale el calentador de forma tal que no est directamente expuesto a salpicaduras de agua lluvia o agua 9...

Страница 21: ...alentador realizar ciclos de encendido apagado a medida que se necesite calor REQUISITOS DEL CABLE DE EXTENSI N hasta 100 30 5 m use un conductor CAE 16 101 200 30 5 61 0 m use un conductor CAE 14 Par...

Страница 22: ...tible y aire y olor y humo en exceso Si esto sucede reemplace el pico de combustible 5 TANQUE DE COMBUSTIBLE L mpielo dos veces por temporada durante per odos de uso frecuente l mpielo dos veces por m...

Страница 23: ...iagrama Verifique los requisitos en la p gina 4 2 Verifique el cableado al encendedor seg n el esquema de cableado en el manual 3 Verifique el espacio entre las sondas de electrodos 2 3 3 mm 4 A n no...

Страница 24: ...rectamente debe ser reparado pero solo por un t cnico de mantenimiento capacitado y experimentado I2 I1 M2 M1 L N 1 3 2 H2 H1 18 AWG VERDE 18 AWG NEGRO 18 AWG BLANCO LLAVE DE ENCENDIDO JUEGO DE CABLES...

Страница 25: ...10 Kerosene Forced Air Heater Operating Instructions and Owner s Manual PAGE LEFT INTENTIONALLY BLANK...

Страница 26: ...ajo es de 8 00 a m a 5 00 p m hora del este de lunes a viernes Incluya el n mero de modelo la fecha de compra y la descripci n del problema en todas sus comunicaciones GARANT A LIMITADA Enerco Technic...

Отзывы: