76
Air flow is not sufficient
for the type of fuel.
Check and clean fan
blades.
Refer to
“Combustion Air Blower,
Solenoid and Flipper.”
Ashes in Air Box.
Clean Air Box.
Refer to
“Air Box.”
Chimney Plugged.
Clean Chimney.
Refer to
“Chimney Stub.”
Burning wet wood.
Add dryer wood as fuel.
Refer to
“Types of Wood.”
Burning unseasoned
wood.
Add seasoned
wood to your fuel.
Refer to
“Types of Wood.”
Flue plugged.
Clean Flue.
Refer to
“Flue.”
Thermometer
(temp gauge)
exceeds
212 degrees
Fahrenheit.
Furnace is not
boiling.
Low water level
Add water.
(Let Furnace cool first)
Refer to
“Water Level Maintenance.”
Charcoal build-up
in rear of firebox.
Excessive ashes.
Remove ashes.
Refer to
“Ash Management and Ash
Removal.”
Failure to rake ashes
periodically.
Rake ashes.
Refer to
“Ash Management and Ash
Removal.”
Blowers continue
to operate and
thermometer is
reading a higher
than setting
temperature.
Water level is low.
Add water.
Refer to
“Filling the Furnace Initially
with Water.”
Defective thermometer.
Replace thermometer.
Refer to
“Thermometer.”
PROBLEM
CAUSE
SOLUTION
PROCEDURE
Содержание 400-4S
Страница 1: ...Outdoor Furnaces TM SAVE THESE INSTRUCTIONS...
Страница 10: ...5 HEATMOR Stainless Steel Outdoor Furnace Model 400 4S Chapter 1...
Страница 73: ...68...
Страница 88: ...83 PROBLEM CAUSE SOLUTION PROCEDURE...
Страница 92: ...87 Outdoor Furnaces...
Страница 93: ...88 NOTES...
Страница 94: ...89 wiring diagram...
Страница 95: ...90 Revised Manual on 07 11 12...