73
Fire is out.
Re-light fire.
Refer to
“Lighting Your HEATMOR™.”
Flue plugged.
Clean Flue.
Refer to
“Flue.”
Blower fins are full of
dust.
Clean Blowers.
Refer to
“Steps to Maintain your
Blower, Solenoid and Flipper.”
Blowers not running
properly or up to speed.
Clean Blowers.
Refer to
“Steps to Maintain your
Blower, Solenoid and Flipper.”
Ashes in Air Box.
Clean Air Box.
Refer to
Air Box.
Too many ashes in
Firebox restricting air
flow.
Clean out ashes with
Auger.
Refer to
“Ash Management and Ash
Removal.”
Restricted air flow into
Blower air inlet.
Clean Blower.
Refer to
“Steps to Maintain your
Blower, Solenoid and Flipper.”
Too much heat draw on
Heatmor Furnace.
Verify HEATMOR™
furnace size for
application.
Contact your
Local Dealer
.
Wood is too big in
diameter - not enough
surface area to burn to
provide enough heat.
Re-size fuel.
Refer to
“Wood.”
Water Level low.
Add Water.
Refer to
“Filling the HEATMOR™
Outdoor Furnace Initially with
Water.”
Excessive moisture in
Fuel.
Use dryer wood.
Refer to
“Types of Wood.”
Furnace has
excessive
moisture in
Firebox.
Chimney plugged.
Clean Chimney.
Refer to
“Chimney Stub / Chimney
Extension(s).”
PROBLEM
CAUSE
SOLUTION
PROCEDURE
Содержание 400-4S
Страница 1: ...Outdoor Furnaces TM SAVE THESE INSTRUCTIONS...
Страница 10: ...5 HEATMOR Stainless Steel Outdoor Furnace Model 400 4S Chapter 1...
Страница 73: ...68...
Страница 88: ...83 PROBLEM CAUSE SOLUTION PROCEDURE...
Страница 92: ...87 Outdoor Furnaces...
Страница 93: ...88 NOTES...
Страница 94: ...89 wiring diagram...
Страница 95: ...90 Revised Manual on 07 11 12...