background image

34

CHAPTER 12

WATER JACKET

Principles of the Water Jacket

Water within the water jacket absorbs heat produced in the firebox. The heated water is used to transfer 

heat from the HEATMOR™ into the building needing heat. The water jacket and the firebox are one welded 

component and can be replaced. 

Maintenance

Keep the proper concentration of water treatment in the water.

Supply Line and Return Line Threaded Connectors

Principles

The HEATMOR™ furnace is designed to draw the supply (hot) water from the bottom of the water jacket. This 

may seem irregular (people know hot water rises), but this method mixes the water in the water jacket better 

and often extends pump life. The return (cooler) water connects to the, upper, rear spud of the HEATMOR™. 

A circulator (pump) moves the water at approximately three to 10 gallons per minute, through both lines under 

very little pressure (3 psi). 

Always attach a BRASS fitting into the STAINLESS STEEL spud to prevent 

galvanic corrosion.

Relief Vent Pipe and Weighted Pop off Ball

Principles

The relief vent pipe is connected to the top of the water jacket. The 

weighted pop off ball sits into the relief vent pipe, putting a pressure 

restriction on the total water jacket. When the water within the water 

jacket is heated it expands. Because of the restriction of the weighted 

ball on the relief vent pipe, the water will expand into the bladder, 

instead of out onto the roof. Any time there is a build up of more than 

two to three psi, the weighted pop off ball will lift up and release the 

pressure, maintaining a completely safe situation.

The weighted pop off ball should always be on the relief vent pipe during normal operation  

of the HEATMOR™ furnace. DO NOT permanently obstruct the relief vent pipe. This could  

cause water jacket or firebox damage if pressure builds.

Relief Vent Pipe and  

Weighted Pop Off Ball

Содержание 400-4S

Страница 1: ...Outdoor Furnaces TM SAVE THESE INSTRUCTIONS...

Страница 2: ...lert you to the possibility of damage to your HEATMORTM Stainless Steel Outdoor Furnace if you do not comply with the corresponding instructions Please read the instructions carefully The HEATMORTM St...

Страница 3: ...R on the Concrete Pad 15 C Caulking Around the Outside Perimeter of HEATMOR 15 D Filling the HEATMOR Outdoor Furnace Initially with Water 16 E Maintaining Water in the Bladder and in the HEATMOR 17 9...

Страница 4: ...e 41 H Firebox Door Latch 41 I Firebox Door Magnet 41 J Firebox Door Gasket and Insulation 41 42 K Firebox Door Frame 43 L Ceramic 43 M Standard Grates and Insulation 44 N Grate Plate 45 O Flash Curta...

Страница 5: ...60 A Controller 60 20 eXTERIOR CLADDING AND INSULATION 61 A Outer Door of HEATMOR 61 B Roof of the HEATMOR 61 C Sides of the HEATMOR 62 D Insulation 62 21 AIR LEAKS 63 A Checking For Air Leaks 63 B W...

Страница 6: ...hope you enjoy the comforts of burning wood This manual contains the manufacturer s recommendations for operation and maintenance of the HEATMOR Stainless Steel Outdoor Furnace Also included are some...

Страница 7: ...in this manual The methods of operation described within this Operations and Maintenance Manual have proven to be effective for HEATMOR Inc for the sole purpose of the operation of a HEATMOR Stainless...

Страница 8: ...3 Units are Safety Listed by Omni Test Laboratories Report 275 O 09 2 Listed to UL2523 2009 and CSA B366 1 11...

Страница 9: ...4 Units are Safety Listed by Omni Test Laboratories Report 275 O 09 2 Listed to UL2523 2009 and CSA B366 1 11...

Страница 10: ...5 HEATMOR Stainless Steel Outdoor Furnace Model 400 4S Chapter 1...

Страница 11: ...Ft 56 BTU s maximum 400 000 Water Jacket Steel Gauge 409 Stainless 10 Firebox Steel Gauge 409 Stainless 10 Integrated Base Steel Gauge 409 Stainless 10 Base of Unit to Bottom of Loading Door Inches 2...

Страница 12: ...7 CHAPTER 3 front Cut Away view of HEATMOR Outdoor Furnace For parts not shown on the cut away view please refer to the appropriate chapter for further details...

Страница 13: ...ney Stub 23 Chimney extension s not shown 24 Rectangular flue 25 Front flue cover plate 26 Rear flue cover plates not shown 27 Flue scraper not shown Ashes 28 Ash pan 29 Ash scraper not shown 30 Ash p...

Страница 14: ...9 CHAPTER 4 rear Cut Away view of HEATMOR Outdoor Furnace For parts not shown on the cut away view please refer to the appropriate chapter for further details...

Страница 15: ...top flue 22 Chimney Stub 23 Chimney extension s not shown 24 Rectangular flue 25 Front flue cover plate 26 Rear flue cover plates 27 Flue scraper not shown Ashes 28 Ash pan 29 Ash scraper not shown 30...

Страница 16: ...ot recommended to install the furance in any form of building Before installing your HEATMORTM Stainless Steel Outdoor Furnace if in the United States always check any and all applicable state and loc...

Страница 17: ...a HEATMORTM Stainless Steel Outdoor Furnace within 50 feet of any flammable structure 5 A HEATMORTM Stainless Steel Outdoor Furnace should be located with consideration to your neighbor s property and...

Страница 18: ...ATMOR Outdoor Furnace 5 Always disconnect any existing electrical connections to any in house heating system before installing the outdoor furnace to any existing indoor heating system or appliances O...

Страница 19: ...4 or any figure in between Patio stones or separate cement pad in front of the loading door should NOT be attached to main base of furnace It is recommended to use steel mesh or R bar in pad for stren...

Страница 20: ...the HEATMOR on the Concrete Base 2 Before setting the HEATMOR onto the concrete base it is a good idea to place a solid sheet of the proper reflective air foil also called bubble foil between the conc...

Страница 21: ...through and remove the air out of the return line as the water flows into the HEATMOR 8 Continue adding water until water flows out the relief vent pipe onto the roof of the HEATMOR 9 Turn off the so...

Страница 22: ...ball back onto the relief vent pipe 8 Turn on the green bladder gate valve and let the bladder fill half full You can check this by feeling the bladder with your hand inserted through the bladder ins...

Страница 23: ...ct a roaring hot fire inside the firebox 2 Never open firebox door immediately after the combustion air blowers have shut off If the water temperature is very close to the high setting you should assu...

Страница 24: ...other inappropriate materials 14 Store ashes outside in a metal container with a metal tight fitting lid away from the outdoor furnace and other buildings No other waste should be placed in this cont...

Страница 25: ...ing The firebox door should only need to be open about two inches At this point the smoke should go up the chimney and not out the firebox door 9 Once the fire is burning rather briskly close the fire...

Страница 26: ...out of the flue covers and even out the ash cover plate THE HEATMOR IS NOT LEAKING Just as moisture collects on the inside of a warm house window on a cold outside day the same thing is occurring ins...

Страница 27: ...sibility of the exhaust igniting and creating a flash back before you open the main firebox door 4 Turn on the light switch The light should turn on and the combustion air blowers should turn off if t...

Страница 28: ...dual Types of Wood will aid in your decisions How does a fire burn out When the temperature of the water has reached its high limit 185 degrees Fahrenheit the combustion air blower s shut off At this...

Страница 29: ...ted to drive off the moisture The higher the moisture content the greater the amount of heat needed and subsequently lost for heating purposes The drier the wood the more rapidly it can be heated and...

Страница 30: ...ency Output Based The percentage of the heat produced that was actually absorbed into the water and transferred into the house from the HeatmorTM Net Efficiency This is the product of the combustion a...

Страница 31: ...a The HEATMOR is designed to be placed outside away from all buildings to maintain optimum safety Refer to the Clearance to Combustibles section 4 Q What is the best method of handling wood A Handle w...

Страница 32: ...ter the water jacket of your HEATMOR Refer to Filling your Furnace Initially for further details or contact your local dealer Removal Replacement of System Water Before removing more than five gallons...

Страница 33: ...t into the relief vent pipe 4 Pour the entire contents of the water treatment chemical as supplied into the HEATMOR furnace 5 Top up your HEATMOR furnace with water and fill the bladder Refer to Filli...

Страница 34: ...ct Immediately flush eyes with plenty of water for at least 15 minutes Inhalation Move to fresh air Ingestion Harmful or fatel if swallowed Give several glasses of water followed by citrus juice then...

Страница 35: ...Before draining the water please refer to Removal Replacement of System Water When installing a completely new system we recommend that the system first be filled with water only After two or three da...

Страница 36: ...n the water within the water jacket expands as it is heated Similarly when the water within the water jacket cools down water is drawn out of the bladder Operation of the Bladder The bladder has a cap...

Страница 37: ...ides a means for the water to freely flow from the water jacket to the bladder allowing expansion and contraction WHEN THE HEATMOR FURNACE IS OPERATING THE BLADDER GATE VALVE MUST BE OPEN Maintenance...

Страница 38: ...ew bladder gate valve 6 Attach the bladder hose to the bladder gate valve and tighten the hose clamp 7 Keeping the bladder gate valve closed add water until furnace is full 8 Open the bladder gate val...

Страница 39: ...e through both lines under very little pressure 3 psi Always attach a BRASS fitting into the STAINLESS STEEL spud to prevent galvanic corrosion Relief Vent Pipe and Weighted Pop off Ball Principles Th...

Страница 40: ...o the wood for a cleaner and hotter burn Operation of the Secondary Air Wing The secondary air wing works on a hinge design with a cable and pulley system to the handle to the front of the furnace If...

Страница 41: ...roller at the back of the furnace will flash a screen that looks like Maintenance Result Wood should not be thrown into the firebox in a rough manner The thermocouples can become dislodged or damaged...

Страница 42: ...d firebox door will not allow smoke to enter or escape the firebox Maintain a tight seal all around the perimeter of the firebox door at all times There may be times when the perimeter of the firebox...

Страница 43: ...w these steps 1 Replace the handle onto the new door just as it was removed 2 Hang the firebox door on the hinges Note Ensure there is a tight seal around the firebox door frame while it is closed and...

Страница 44: ...e build up Removal and Replacement To remove and replace the door hoses use the following steps 1 Turn off power to the air combustion blowers 2 Ensure that the fire in the firebox is extinguished whi...

Страница 45: ...of controlling the opening and closing of the firebox door By opening the firebox door only until the door handle hits the second stage of the safety latch gives a space for fresh air to enter the fi...

Страница 46: ...into the HEATMOR Operation 1 Open the firebox door as you step backwards towards the exterior door This allows you to be out of the way if there is a flash back or smoke exiting the door opening 2 Sti...

Страница 47: ...ld gasket from underneath the old silicone 3 Remove all old silicone with a wire wheel or steel brush 4 Replace with a single length of new gasket material Do not pack or over stretch the new gasket O...

Страница 48: ...burning temperature of 1100 degrees Fahrenheit much faster Maintenance Result Wood should not be thrown into the firebox in a rough manner Do not scrape the ceramic as the ceramic can become dislodged...

Страница 49: ...esult in hot coals slipping under the grates causing warpage of the grates 3 Make sure the narrow side of the slot is next to the fire 4 Replace broken grates immediately or a chain reaction of broken...

Страница 50: ...plate is always resting at the bottom of the firebox on top of the grates 4 Replace a warped grate plate immediately or non efficient fire may result 5 The grate plate will not break under reasonable...

Страница 51: ...e flash curtain restricts the amount of direct heat that contacts the firebox door directly Maintenance Result Leaving the flash curtain in place is effective for the principles outlined above Removal...

Страница 52: ...oid it will open the flipper and force air into the firebox The flipper must completely open and close all of the time When it is closed it must seal completely If more than a wiff of smoke is coming...

Страница 53: ...ctly it causes a snowball effect of problems Primary Secondary Air Motor Principles The primary secondary air motor regulates the air flow to under the grates primary air or to the top of the airbox s...

Страница 54: ...tly for safe operation of the Heatmor Principle The fan switch turns the fan on while the outer door is opened to clear the possible excess fuel build up in the firebox Along with normal recommended s...

Страница 55: ...to higher levels Discharging smoke at a higher level helps keep smoke above property level especially on low pressure or cloudy hazy or wet days When installing chimney extensions you must have no les...

Страница 56: ...g into the up position 4 Using the flue scraper provided with the HEATMORTM furnace push the dust to the back of the flue and then from the back of the furnace push the dust into the firebox Remove th...

Страница 57: ...moving the ashes from the ash pan before it is completely full ensures the proper airflow from below the grates is maintained and also ensures the ashes can drop through the grates into the ash pan As...

Страница 58: ...ion air that flows upwards through the grates A reasonable amount of ashes two to four gallons should be removed during each ash removal Ash Scraper Principles The scraper provides a convenient and cl...

Страница 59: ...e in the relatively cool chimney flue of a slow burning fire As a result creosote residue accumulates on the flue lining When ignited this creosote makes an extremely hot fire The chimney connector an...

Страница 60: ...emperature gauges have different sized wells Often they are not interchangeable Replace with the correct unit from your local dealer NOTE The temperature reading on the temperature gauge may not coinc...

Страница 61: ...hould be connected to it s own circuit Electrical Supply Junction Box Principles The electrical components of the HEATMOR furnace are pre wired at the factory All the wiring becomes centralized in the...

Страница 62: ...t 1 Turn off the main power supply to the HEATMOR 2 Pull the thermocouple straight out of the well 3 Disconnect the thermocouple wire connection from the controller and re wire the new thermocouple 4...

Страница 63: ...the power 11 Adjust the dial and white wheel to the preferred settings Front Light and Fan Power Switch Principles 1 To provide light while fueling 2 To provide a means of turning off the combustion...

Страница 64: ...ce the wires as in the diagram 6 Secure the cover plate 7 Turn the main electrical power supply back on to the HEATMOR Note It is recommended to contact a licensed electrician to perform the above ope...

Страница 65: ...When the switch is closed the fan will turn on and the primary secondary motor will be set to the initial loading setting The 400 4S is considered Loaded when the light switch is flipped up then down...

Страница 66: ...al and Replacement To remove the outer door the lock handle must be unlocked and opened Pick up the old door from the hinges and place and secure the new door into position Test the door to ensure a t...

Страница 67: ...ge the color of your unit they can be replaced with different steel siding Follow the following steps or contact your local dealer 1 Remove all the screws holding the damaged steel siding secure 2 Lif...

Страница 68: ...into the furnace When the furnace is smoking cover the chimney and turn off the blower and watch for smoke leaks Air leaks cause the fire to not burn as hot or efficiently In result you will use more...

Страница 69: ...64 WATER LEAKS If you suspect that your HEATMOR Stainless Steel Outdoor Furnace has developed a water leak please contact your local dealer for verification and further details CHAPTER 22...

Страница 70: ...aled to the outer face of the water jacket by a sealing gasket As water passes through the domestic coil the water in the water jacket heats it Maintenance Result Make sure a tight seal is maintained...

Страница 71: ...in firebox and bring your furnace up to temperature Refer to the Lighting the HeatmorTM for the first time section of the HeatmorTM Operations and Maintenance Manual 3 Once your furnace is up to temp...

Страница 72: ...t or something similar will cover the chimney keeping unwanted moisture and visitors away 6 Properly clean Fan s Refer to the Air Supply section of the HeatmorTM Operations and Maintenance Manual 1 Tu...

Страница 73: ...68...

Страница 74: ...ng normal operation the atmosphere inside the firebox will exceed the dew point causing condensation Refer to Furnace has excessive moisture in firebox Located in Trouble Shooting and Solutions Dew Po...

Страница 75: ...contact your local dealer Refer to Firebox Door Hoses and Elbows Located in Firebox and Other Components 9 Q My furnace combustion blower continues to run but the fire will not burn until I open the d...

Страница 76: ...al Dealer Blower Flipper Assembly plate not tight Tighten wing nuts Refer to Steps to Maintain your Blower and Flipper Assembly Firebox door ajar not shut tight Close Fire Door Tight Refer to Firebox...

Страница 77: ...Replace Pump or Cartridge Contact your Local Dealer Air trapped in water lines Bleed lines Contact your Local Dealer Malfunction of heating appliances in building Repair adjust or replace Contact you...

Страница 78: ...ement and Ash Removal Restricted air flow into Blower air inlet Clean Blower Refer to Steps to Maintain your Blower Solenoid and Flipper Too much heat draw on Heatmor Furnace Verify HEATMOR furnace si...

Страница 79: ...ess cured wood Refer to Wood Firebox Door pops or rattles Elbow s or hoses are clogged restricting water flow through door hoses Unclog or replace elbow s or hoses Refer to Firebox Door Hoses and Elbo...

Страница 80: ...temperatures are warmer and supply controls have not been adjusted Adjust water flow Contact your Local Dealer High limit switch set too low Adjust setting Refer to Electrical Water Temperature Range...

Страница 81: ...rmometer temp gauge exceeds 212 degrees Fahrenheit Furnace is not boiling Low water level Add water Let Furnace cool first Refer to Water Level Maintenance Charcoal build up in rear of firebox Excessi...

Страница 82: ...ycle to start Refer to Loading Wood into the HEATMOR Firebox air leak Check all seals for or air leaks Run a smoke check Refer to Air Leaks Flash Curtain Heat Shield has been removed Install Flash Cur...

Страница 83: ...ng Replace door hoses Refer to Firebox Door Hoses and Elbows Bladder gate valve needs adjusting Adjust and tighten gate valve Refer to Bladder Gate Valve and Bladder Hose Hose clamps are leaking Tight...

Страница 84: ...nd hard Refer to Types of Wood Wood is too small of pieces Add larger pieces of wood Refer to Wood Flue is clogged Clean Flue Refer to Flue Using more heat in building than you realize heating more sq...

Страница 85: ...pliance getting more than it s share of the total flow of hot water Balance the system by adjusting the flows of water to the different heating appliances Contact your Local Dealer Defective in house...

Страница 86: ...instead of pure hotwater Contact your Local Dealer Manifold not balanced properly One appliance getting more than its share of the total flow of hot water Balance the system by adjusting the flow of w...

Страница 87: ...at least eight gallons per minute Check pump and installation Contact your Local Dealer No contact paste applied to well of Temperature Gauge Remove Temperature Gauge from well and apply paste Refer...

Страница 88: ...83 PROBLEM CAUSE SOLUTION PROCEDURE...

Страница 89: ...steel limited LIFETIME warranty If you have any questions please contact your local dealer Complete and send the furnace registration to your local dealer distributor or heatmor inc Within 30 days of...

Страница 90: ...ide of front door for data plate that has model information Model _________________________________________________________________ Referred By ________________________________________________________...

Страница 91: ...ve been presented with a key for my locked Heatmor and assume the responsibility of operation and maintenance of it ________________________________________________ Customer Signature ________________...

Страница 92: ...87 Outdoor Furnaces...

Страница 93: ...88 NOTES...

Страница 94: ...89 wiring diagram...

Страница 95: ...90 Revised Manual on 07 11 12...

Отзывы: