28467 Rev I
16
02-02
NOVUS TOP DV GAS APPLIANCE INSTALLATION INSTRUCTIONS
a. Standing Pilot Ignition
This standing pilot appliance does not require a 110V AC supply to operate. It is suggested that a 110V junction
box be installed with a switched outlet for the optional fan and an always-powered outlet for the optional remote
control.
Only heater-listed appliances may be connected to a thermostat (not supplied). Use a thermostat that is
compatible with a millivolt gas valve. See Figure 28.
b. Electronic Ignition
1)
This electronic ignition appliance requires a 110V AC supply to operate. It is suggested that a switched
110V junction box with two switched outlets be installed to power the optional remote control and/or fan.
2)
Only heater listed appliances may be connected to a thermostat. If connecting a 24V thermostat (not
supplied), disconnect the black wire from the transformer at the ignition control. Connect the thermostat
wires between the ignition control and the black wire (from transformer). See Figure 29.
NO additional wire is
supplied by Hearth
Technologies Inc.
WARNING!
The standing pilot version of This appliance DOES
NOT require a 110V AC supply for operation.
Connecting the appliance/Wall Switch to a 110V AC
supply will cause the appliance to malfunction and
destroy the Valve and Thermopile.
Figure 30 - Junction Box Detail
Figure 29 - Electronic Ignition Wiring Diagram
c. Junction Box Wiring
We recommend you operate the two outlets on
separate circuits. This allows independent
operation of the appliance and fan. Independent
operation is obtained by using minimum 14-3 with
ground Romex and separating the two outlets by
breaking out the tab as shown in Figure 30.
All manuals and user guides at all-guides.com