Heat&GloGlo 6000CF-OAK-IPI Скачать руководство пользователя страница 50

53

Heat & Glo  •  6000CF-OAK-IPI  •  2092-900  Rev. 

I

  •  1/06

D.   Limited Lifetime Warranty

LIMITED LIFETIME WARRANTY

HEAT & GLO GAS APPLIANCE PRODUCTS

BASIC ONE-YEAR WARRANTY.  HEAT & GLO, a brand of HEARTH & HOME TECHNOLOGIES INC., located at 20802 Kensington

Boulevard, Lakeville, MN 55044, (“HEAT & GLO”) warrants to the original owner that your new HEAT & GLO Gas Appliance (the “Product”)

will be free from defects in materials and workmanship for a period of one year from the date of in

stallation.  During the first year, HEAT & GLO

will replace or repair, at its discretion, any defective components at its sole cost and expense, including payment of all reas

onable labor costs

incurred in replacing or repairing such components. This basic warranty is subject to the conditions, 

exclusions and limitations described

below.

EXTENDED LIFETIME COVERAGE.  HEAT & GLO warrants that the firebox, heat exchanger, log(s), and burner will not be defective in

material or workmanship during the period the Product is owned by the original owner, subject to the following conditions, exclusions and

limitations described below.

CONDITIONS, EXCLUSIONS AND LIMITATIONS:

1. This warranty applies to the original owner only and is nontransferable.

2. This warranty applies only to Products installed in the United States of America or Canada.

3. This warranty is limited to the replacement or repair of defective components or workmanship and HEA

T & GLO may fully discharge all

obligations under this warranty by repairing or replacing, at its discretion, the defective components. The maximum amount recoverable

under this warranty is limited to the purchase price of the Product and, if HEA

T & GLO is unable to provide replacement or repair in an

expedient and cost-effective manner, HEAT & GLO may discharge all obligations under this warranty by refunding the purchase price

of the Product.  IN NO EVENT SHALL HEAT & GLO BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES CAUSED

BY DEFECTS IN THE PRODUCT.

4. Any labor and related repair charges relating to the costs and expenses of replacing or repairing defective components under 

the Limited

Lifetime Warranty are not covered by this warranty, except as provided for under the Basic One-Year Warranty.

5. Components and parts made by other manufacturers, whether sold with the Product or added thereafter, are NOT covered by this

warranty unless expressly authorized and approved by HEAT & GLO in writing.

6. Any damages caused by environmental conditions, inadequate ventilation or drafting caused by tight sealing construction of th

e structure,

air handling devices such as exhaust fans or forced air furnaces, or other such causes are not covered by this warranty

.

7. This warranty will be void if:

a) The Product is not installed, operated and maintained in compliance with local building codes and with the instructions in the

Installer’s Guide, Owner’s Guide and Listing Agent Identification Label furnished with the Product.

b) Any parts or components made by other manufacturers are added or used in the Product, unless expressly authorized and

approved by HEAT & GLO in writing.

c) Any service work is performed on the Product by anyone other than an authorized HEAT & GLO representative.

d) The Product is damaged due to shipping, improper handling, accident, abuse or misuse.

e) Fuels other than those specified in the Installer’s Guide and Owner’s Guide are used.

f ) Modification was made to the Product which was not expressly authorized and approved by HEAT & GLO in writing.

EXCEPT TO THE EXTENT PROVIDED BY LAW, HEAT & GLO MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY

SPECIFIED HEREIN. THE DURA TION OF ANY IMPLIED WARRANTY IS LIMITED T O THE DURATION OF THE W ARRANTY

SPECIFIED ABOVE.

Some states do not allow limitations on how long an implied warranty lasts, or do not allow exclusion or limitation of incident

al or consequential

damages, so those limitations may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which

vary from State to State.

If warranty service is needed you should contact your installing dealer and if the installing dealer is 

unable to provide necessary parts or

components, contact the nearest authorized HEAT & GLO dealer or supplier.

NOTES TO CUSTOMER:

1. In order to insure proper installation, operation and maintenance HEAT & GLO strongly recommends annual servicing by an authorized

HEAT & GLO dealer.

2. Please complete this information and retain this warranty in a safe place for future reference: Installation Date:___________

_______

Model #:______________________ Serial #:__________________________ Installing Contractor:_________________________

3. HEAT & GLO reserves the right to make changes at any time, without notice, in design, material, specifications and prices of the Product.

HEAT & GLO also reserves the right to discontinue styles and products.

© 2005 Hearth & Home Technologies Inc.

060-981D   3/05

Содержание 6000CF-OAK-IPI

Страница 1: ...dren in same room as appliance Alert children and adults to hazards of high temperatures Do NOT operate with protective barriers open or removed Keep clothing furniture draperies and other combustible...

Страница 2: ...ce can be found on the rating plate usually located in the control area of the appliance Homeowner Reference Information Heat Glo a of Hearth Home Technologies Inc brand 20802 Kensington Boulevard Lak...

Страница 3: ...tact Information 54 Section 1 Listing and Code Approvals A Appliance Certification 4 B Glass Specifications 4 C BTU Specifications 4 D High Altitude Installations 4 E Non Combustible Materials Specifi...

Страница 4: ...ifice to a smaller size Input rate should be reduced by 4 for each 1000 feet above a 2000 foot elevation in the U S A or 10 for elevations between 2000 and 4500 feet in Canada If the heating value of...

Страница 5: ...ing The vent system components and trim doors are shipped in separate packages The gas logs may be packaged separately and must be field installed Report to your dealer any parts damaged in shipment p...

Страница 6: ...from traffic areas A Selecting Appliance Location When selecting a location for your appliance it is important to consider the required clearances to walls see Figure 3 1 Figure 3 1 Appliance Location...

Страница 7: ...her prevent drafts the wall shield and ceiling firestops should be caulked with high temperature caulk to seal gaps Gas line holes and other openings should be caulked with C Clearances Fire Risk Cons...

Страница 8: ...ther Combustibles above Appliance Figure 3 4 Clearances to Mantel Legs or Wall Projections Acceptable on both sides of opening Note All measurements in inches 1 inch 3 feet MANTEL LEG Top View 7 1 4 7...

Страница 9: ...Over 18 12 to 20 12 7 5 Over 20 12 to 21 12 8 0 Figure 4 1 Figure 4 2 Minimum Height from Roof to Lowest Discharge Opening Termination Locations 4 Measure horizontal clearances from this surface Meas...

Страница 10: ...nd with an overhang are permitted with the dimensions specified for vinyl or non vinyl siding and soffits 1 There must be 3 feet minimum between termination caps 2 All mechanical air intakes within 10...

Страница 11: ...run A length of straight pipe is allowed between two 450 elbows see Figure 5 1 Figure 5 1 A Vent Table Key The abbreviations listed in this vent table key are used in the vent diagrams Symbol Descrip...

Страница 12: ...pipe may cause fire WARNING 1 Top Vent Horizontal Termination One Elbow Two Elbows V1 Minimum H1 Maximum 6 inches 152mm 3 ft 914 mm 1 ft 305 mm 3 ft 914 mm 2 ft 610 mm 6 ft 1 8 m 3 ft 914 mm 9 ft 2 7...

Страница 13: ...457 mm 6 ft 1 8 m 1 ft 305 mm 3 ft 914 mm 1 ft 305 mm 3 ft 914 mm 2 ft 607 mm 6 ft 1 8 m 2 ft 610 mm 6 ft 1 8 m 2 ft 610 mm 6 ft 1 8 m 4 ft 1 4 m 12 ft 3 7 m 3 ft 914 mm 9 ft 2 7 m 3 ft 914 mm 9 ft 2...

Страница 14: ...t 305 mm 3 ft 914 mm 2 ft 607 mm 6 ft 1 8 m 4 ft 1 2 m 12 ft 3 7 m V1 V2 H1 50 ft 15 2m Max No specific restrictions on this value EXCEPT V1 V2 H1 cannot exceed 50 ft 15 2m V1 6 inches 152 mm Min NOTE...

Страница 15: ...tinued V1 H1 H2 V2 V1 V2 Minimum H1 H2 Maximum 6 in 152 mm 3 ft 914 mm 3 ft 914 mm 1 ft 305 mm 3 ft 914 mm 3 ft 914 mm 2 ft 610 mm 6 ft 1 8 m 6 ft 1 8 m 4 ft 1 2 m 12 ft 3 7 m 12 ft 3 7 m H1 H2 17 ft...

Страница 16: ...the shield in place using the four pilot holes pro vided in the part Position the shield so the longest dimension 13 1 2 inch is placed in same direction the elbow is pointing Center the shield direc...

Страница 17: ...e being penetrated is surrounded by noncombusti ble materials such as concrete a hole with diameter one inch greater than the pipe is acceptable B Wall Penetration Framing Figure 6 5 Horizontal Ventin...

Страница 18: ...the vent pipe Installing Attic Shield Note An additional ceiling firestop is not required if attic shield is used Frame opening for attic shield Attic shield may be installed above or below ceiling s...

Страница 19: ...d slots The face of the sheetrock ledge assembly and the unit surround should be flush to each other Figure 7 3 Remove the lower access panel to run the electrical and gas lines to the unit see Figure...

Страница 20: ...bs on each side Keep nailing tabs flush with the framing Secure the appliance to the framing by using nails or screws through the nailing tabs Figure 7 4 Proper Positioning Leveling and Securing of Ap...

Страница 21: ...7 8 3 Center the Flue Restrictor on vent and secure in place by using two self tapping screws see Figure 7 8 CHART Vertical Top Vent NG Top Vent LP 4 1 1 No Restrictor 8 2 2 1 2 15 3 3 3 2 20 3 4 3 3...

Страница 22: ...from horizontal to vertical one screw minimum should be put in the outer flue at the horizontal elbow joint to prevent the elbow from rotating Use screws no longer than 1 inch If predrilling screw ho...

Страница 23: ...ng the inner and outer flues of the slip section can be cut to the desired length Assembling Minimum Installations MI Sections MI sections are non unitized so that they can be cut to a certain length...

Страница 24: ...of pipe must be supported every 8 feet after the 25 foot maximum unsupported rise The vent support or plumber s strap spaced 120 apart may be used to do this see Figure 8 8 Horizontal Sections Horizon...

Страница 25: ...rom the pipe section see Figure 8 12 Installing the Horizontal Termination Cap Vent termination must not be recessed in the wall Siding may be brought to the edge of the cap base Flash and seal as app...

Страница 26: ...oof Pitch H Min Ft HORIZONTAL OVERHANG VERTICAL WALL TERMINATION CAP 12 X ROOF PITCH IS X 12 LOWEST DISCHARGE OPENING H MIN MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE OPENING 2 FT MIN 20 INCHES To a...

Страница 27: ...both halves of the storm collar with two screws see Figure 8 15 Wrap the storm collar around the exposed pipe section and align brackets Insert a bolt provided through the brackets and tighten nut to...

Страница 28: ...o the 1 2 inch 13mm control valve inlet If substituting for these components please consult local codes for compliance NOTE The gap between supply piping and gas access hole may be caulked with high t...

Страница 29: ...heck with local authorities Ensure that gas line does not come in contact with outer wrap of appliance Follow local codes Incoming gas line should be piped into the valve com partment and connected to...

Страница 30: ...irements Wiring for optional accessories should be done now to avoid reconstruction This appliance may be used with a wall switch wall mounted thermostat and or a remote control If using thermostat us...

Страница 31: ...TERMITTENT PILOT IGNITOR IGNITION MODULE 3V ON OFF WALL SWITCH LOW VOLTAGE PLUG IN 3V TRANSFORMER NEUTRAL HOT GROUND FLAME SPARKER SENSOR REMOTE CONTROL SEE NOTE 1 ORG WHT VALVE PIGGYBACK ON OFF SWITC...

Страница 32: ...res to the junction box as shown Add a 1 4 inch insulated female connector to the red switch leg wire route it through the knockout in the face of the junction box and connect to the top fan switch co...

Страница 33: ...y a 300o F minimum sealant Figure 11 2 Mantel Leg or Wall Projections Acceptable on both sides of opening Figure 11 1 Clearances to Mantels or other Combustibles above Appliance SEALANT MATERIAL 0 FIN...

Страница 34: ...ee Ser vice Parts List for appropriate accessories Refer to Section 16 Removing Optional GFK 160A Fan ITEM 1 Remove front from the fireplace see Fig ure 12 1 2 Remove glass assembly from the fire plac...

Страница 35: ...acing the Ember Material Ember material is shipped with this gas appliance To place the ember material Embers CANNOT be placed directly over ports Care should be taken not to cover the lighting trail...

Страница 36: ...LOG 1 SRV385 720 Place the log so that the notches on the bottom of log line up with the grate bars Note There should be about 1 4 gap between the log and the hump on the burner STEP 3 LOG 2 SRV385 7...

Страница 37: ...the slot in the underside of this log Place the log so that this slot fits onto the right metal tab on log 1 Swing the lower end so that it sits in or above the dent on the top of log 2 STEP 6 LOG 5...

Страница 38: ...er up the gap between the sheet rock and the appliance Do not obstruct or modify the air inlet outlet grilles When overlapping on both sides leave enough space so that the bottom grille can be lowered...

Страница 39: ...er removed Contact your dealer or Hearth Home Technologies if the barrier is not present or help is needed to properly install one Glass door must be in place when appliance is operating Risk of Combu...

Страница 40: ...r maintenance can cause injury or property dam age Refer to the owner s informa tion manual provided with this ap pliance This appliance needs fresh air for safe operation and must be in stalled so th...

Страница 41: ...nt or if appliance will not be used for an extended period of time Property damage possible from elevated temperatures CAUTION Fire Hazard Keep combustible materials gasoline and other flammable vapor...

Страница 42: ...module with ON OFF switch in ON position Acceptable readings of a good transformer are between 3 2 and 2 8 volts AC b A shorted or loose connection in wiring configuration or wiring harness Remove and...

Страница 43: ...ch or wall switch in ON position Hold ground wire about 3 16 inch away from I terminal on module If there is no spark at I terminal module must be replaced If there is a spark at I terminal module is...

Страница 44: ...s Handle glass assembly with care NOTE Clean glass after initial 3 4 hours operation Longer operation without cleaning glass may cause a permanent white film on glass CAUTION When cleaning glass door...

Страница 45: ...t as necessary 2 Replace appliance if firebox has been perforated Burner Ignition and Operation 1 Verify burner is properly secured and aligned with pilot or igniter 2 Clean off burner top inspect for...

Страница 46: ...raming dimensions and clearances refer to Section 3 Figure 16 1 Appliance Dimensions A B C D E F G H I J K L M N O P Q Inches 28 1 2 14 1 4 21 1 2 12 7 8 8 38 6 7 8 2 1 8 21 1 2 32 1 4 36 1 8 41 1 8 7...

Страница 47: ...DVP12A 3 to12 DVP12MI 3 to12 DVP24MI 3 to 24 10 1 2 in 10 7 8 in 45 7 3 8 in 11 3 8 in 1 1 4 in 9 1 4 in 13 1 4 in 1 2 in TYP DVP90 DVP90ST 90 Elbow 10 in 1 in 12 in 14 in 1 in 8 in 6 in 10 in 1 1 2 i...

Страница 48: ...erm Cap Effective Length Effective Length TRAP1 4 1 8 in 5 5 8 in TRAP2 6 3 4 in 10 5 8 in Wall Shield Firestop Heat Shield DVP TRAP1 DVP TRAPK1 Horizontal Termination Cap Kit DVP90ST Wall Shield Fire...

Страница 49: ...13 1 4 in 24 5 8 in 27 1 2 in RF6M Roof Flashing Multi pak 31 in 24 5 8 in 13 1 4 in RF12M Roof Flashing Multi pak BEK Trap Cap Brick Extension 13 3 4 in 5 in 13 3 4 in 7 1 4 in 5 1 4 in 12 1 2 in DV...

Страница 50: ...pressly authorized and approved by HEAT GLO in writing 6 Anydamages caused by environmental conditions inadequate ventilation or drafting caused by tight sealing construction of th estructure air hand...

Страница 51: ...ontact your Heat Glo dealer with any questions or concerns For the number of your nearest Heat Glo dealer please call 1 888 427 3973 Printed in U S A Copyright 2006 DO NOT DISCARD THIS MANUAL CAUTION...

Отзывы: