19
Heat & Glo • 6000CF-OAK-IPI • 2092-900 Rev.
I
• 1/06
A. Attaching Sheetrock Ledges
Figure 7.1
The sheetrock ledges will attach to the top of the unit (see
Figure 7.2).
Figure 7.2
Attach sheetrock ledges together using the attachment
holes (see Figure 7.1).
Attach sheetrock ledge assembly to the top of the unit using
the provided slots. The face of the sheetrock ledge assembly
and the unit surround should be flush to each other.
Figure 7.3
Remove the lower access panel to run the electrical and
gas lines to the unit (see Figure 7.3).
Once the electrical and gas lines are hooked up, the lower
access panel must be put back on the unit.
SEE DETAIL B
CLEARANCE SLOT
SHEETROCK
LEDGE
UNIT
SURROUND
ATTACHMENT
HOLES
6 PLACES
DETAIL B
B. Temporary Access Panel
Appliance Preparation
7
SEE
DETAIL A
NAILING
TAB
DETAIL A
ATTACHMENT
HOLES
LOWER ACCESS PANEL