32
Heat & Glo • 6000CF-OAK-IPI • 2092-900 Rev.
I
• 1/06
GRN wire
inside box
Copper
ground attached
to GRN screw with
GRN wire
14/2WG
Cover Plate
outside firebox
Romex
Connector
WHT
WHT
BLK
BLK
E. Junction Box Installation
F. Wall Switch Installation for Fan (Optional)
Figure 10.2 Junction Box Detail
Figure 10.3 Junction Box Wired to Wall Switch
If the box is being wired to a wall
mounted switch for use with a fan (See
Figure 10.3):
• The power supply for the appliance
must be brought into a switch box.
• The power can then be supplied from
the switch box to the appliance using
a minimum of 14-3 with ground wire.
• At the switch box connect the black
(hot) wire and red (switch leg) wire to
the wall switch as shown.
• At the appliance connect the black
(hot), white (neutral) and green
(ground) wires to the junction box as
shown.
• Add a 1/4 inch insulated female
connector to the red (switch leg) wire,
route it through the knockout in the
face of the junction box, and connect
to the top fan switch connector (1/4
inch male) as shown.
If the box is being wired from the appliance:
• Remove the screw attaching the junction box
to the outer shell, rotate the junction box
inward to disengage it from the outer shell (see
Figure 10.2).
• Pull the electrical wires from outside the
appliance through this opening into the valve
compartment.
• Loosen the two screws on the Romex
connector (not included with unit), feed the
necessary length of wire through the connector
and tighten the screws.
• Make all necessary wire connections to the
receptacle and assemble the receptacle and
cover to the junction box.
NOTE:
Do NOT wire
110VAC to wall switch.
Red
Red
Black
Black
Green
Green
White
White
Re
d
B
lac
k
G
reen
W
hi
te
SWITCH BOX
JUNCTION BOX
POWER
SUPPLY WIRES
SWITCH
MINIMUM 14-3 AWG
WITH GROUND