30
Heat & Glo • 6000CF-OAK-IPI • 2092-900 Rev.
I
• 1/06
A. Recommendation for Wire
This appliance requires 110-120 VAC be wired to the junction
box either for proper operation of the appliance.
Electrical Information
10
NOTE:
This appliance must be electrically wired and
grounded in accordance with local codes or, in the absence
of local codes, with
National Electric Code ANSI/NFPA 70-
latest edition
or the
Canadian Electric Code, CSA C221.1
.
C. Intellifire Ignition System Wiring
B. Connecting to the Appliance
WARNING
Wire 110V to electrical junction box.
Do NOT wire 110V to valve.
Do NOT wire 110V to wall switch.
• Incorrect wiring will damage millivolt valves.
• Incorrect wiring will override IPI safety
lockout and may cause explosion.
This appliance requires a 110 VAC supply to the appliance
junction box for operation. A wiring diagram is shown in
Figure 10.1.
This appliance is equipped with an Intellifire control valve
which operates on a 3 volt system.
This appliance is supplied with a battery pack and a 3 volt
AC transformer, which requires the installation of the
supplied junction box. It is highly recommended that the
junction box be installed at this time to avoid reconstruction.
The battery pack requires two D cell batteries (not
included).
CAUTION
Battery polarity must be correct or module damage will
occur.
Optional Accessories Requirements
Wiring for optional accessories should be done now to
avoid reconstruction.
• This appliance may be used with a wall switch, wall
mounted thermostat and/or a remote control.
• If using thermostat use one compatible with a millivolt
gas valve system.
• Follow parameters for locating thermostat (see individual
thermostat instructions) to ensure proper operation of
appliance.
• Use low resistance thermostat wire for wiring from igni-
tion system to the wall switch and thermostat.
• Keep wire lengths short as possible by removing any
excess wire length.
• Low voltage and 110 VAC voltage cannot be shared within
the same wall box.
CAUTION
Label all wires prior to disconnection when servicing con-
trols. Wiring errors can cause improper and dangerous op-
eration. Verify proper operation after servicing.
Shock hazard.
• Replace damaged wire with type 105
O
C
rated wire.
• Wire must have high temperature insulation.
WARNING
D. Wall Switch
Position the wall switch in the desired position on the wall.
An assembly of 18 ft of 20 AWG is provided with the fire-
place to connect the wall switch to the appliance. Instead of
the supplied assembly, wire with a length of 25 ft or less and
a gauge of 20 AWG through 14 AWG is acceptable. The
wire needs a jacket with a temperature rating of 140
o
F (60
o
C)
or higher. At the appliance connect the wire to the ON/OFF
switch pigtails.
NOTE:
Batteries cannot be placed in the battery pack
while using the 3 volt AC transformer. The transformer
must be unplugged if the battery pack is used or battery
life will be reduced.