background image

059305-00  Rev. D 

 

Heat-Timer Corp.

Main Menu

The main Menu is used to configure setpoints, TMC limits, and 

modulating gain.

ETV Platinum Plus Menus

TV Platinum Plus Display and Programming     43          

Содержание ETV Platinum Plus

Страница 1: ...Timer control is strictly an operating control it should never be used as a primary limit or safety control All equipment must have its own certified limit and safety controls required by local codes...

Страница 2: ...allation 14 Valve Direction Default 14 Mounting the Actuator to the Mixing Valve 15 Mounting the ETV Platinum Plus Module 18 Mounting the Enclosure 18 Mounting the Display Module 19 Wiring the ETV Pla...

Страница 3: ...TE Programming mode may be password protected See page 49 3 Variable Function Buttons See Display and Variable Function Buttons on page 33 10 Motorized Mixing Valve Modulating Signal Connections for V...

Страница 4: ...a temperature setpoint It does that by mixing two different water temperatures from two different sources a hot water source and a cold water source The hot water source can be a hot water boiler a ho...

Страница 5: ...xiliary Temperature Sensors at least 6 feet 1 8 meters from the valve NOTE Alarms for auxiliary sensors are available with RINET communication option only and is accessed via internet through Building...

Страница 6: ...rized ball valve powered OPEN and powered CLOSED or a Normally Open N O or Normally Closed N C solenoid type valve Heat Timer recommends the use of a motorized ball valve with battery backup TMC valve...

Страница 7: ...ut Relay Rating TMC Lockout 3A at 120Vac 60Hz Modem Reset 5A resistive at 120Vac 60Hz Valve Output 1A inductive at 120Vac 60Hz Inputs System Temperature Aux Temp 1 Temp or Switch Aux Temp 2 Temp or Sw...

Страница 8: ...Size 1 1 1 2 2 Cv 5 7 12 18 29 46 73 3 8 12 20 32 50 80 126 4 9 15 23 37 58 93 145 5 10 16 26 41 64 103 162 6 12 18 28 45 70 113 178 7 13 20 31 50 78 125 192 8 14 21 33 53 83 132 205 9 15 22 35 56 88...

Страница 9: ...ETV Platinum Plus Stainless Steel Valve Dimensional Specifications 9 059305 00 Rev D Heat Timer Corp...

Страница 10: ...latinum Plus Installation and Operation Manual ValveModel Voltage Input Absorbed Current Absorbed Power Temp Rating Working Time Max Torque Limit Switches Battery Backup Option 1 1 2 24Vac 4 F to 131...

Страница 11: ...iring on page 27 Reference the ETV Platinum Plus Remote Communication manual for addition information 7 Calibrating the Actuator refer to page 29 8 Completing initial programming of the ETV Platinum P...

Страница 12: ...he pipe see Figure 2 When possible use a tee fitting rather than an elbow fitting where the piping changes direction within the allowable sensor placement distance from the valve The sensor probe is t...

Страница 13: ...m of 32 inches 81 3cm as measured from pipe center to pipe center In applications where piping a thermal trap is not feasible or in applications where there is a recirculating pump between a heating s...

Страница 14: ...ETV valve body can be oriented in such a way that the COLD Port A and HOT Port B are interchangeable to accommodate existing piping In this alternate configuration Port A becomes the HOT port and Port...

Страница 15: ...ctuator as shown in Figure 7 a Lower the Manual Tab to place the Actuator in Manual Override mode b Turn the Manual Tab counter clockwise to drive the threaded shaft to the full lower position c Raise...

Страница 16: ...ve NOTE The U bolt must also be aligned with the valve groove as shown in Figure 8 If necessary use the actuator manual tab to adjust the position of the actuator frame and mounting holes to align the...

Страница 17: ...venly and resulting in potential damage to the actuator motor 5 Once the actuator is completely mounted onto the valve the actuator cover can be remove to allow access for wiring setting of Dip Switch...

Страница 18: ...e device The device can be mounted a maximum of 500 feet 152 4 meters from the valve location but should be mounted as near to the valve as possible to avoid excessive wire runs DO NOT mount the devic...

Страница 19: ...TE The battery is a coin lithium battery CR2032 Heat Timer p n 020002 00 that is used to maintain the control s date and time during power outages The battery can maintain the clock for up to a total...

Страница 20: ...o may result in severe personal injury or death Use a separate circuit breaker for the control Do not share the control power with other major equipment pumps or motors Heat Timer recommends the insta...

Страница 21: ...an alternative External Transformer Kit Heat Timer p n 950023 00 can be used to provide power to the Actuator 4 Connect 24Vac power from the ETV Platinum Plus module to the Actuator a Run the Actuato...

Страница 22: ...round wire from Actuator terminal M to terminal 14 on the ETV Platinum Plus module 2 Connect the second Actuator a Run the wiring through a knockout located on the bottom of the ETV Platinum Plus encl...

Страница 23: ...TMC valve terminals An external power source is required and must be connected in series as shown in the diagram Refer to TMC Valve on page 6 for information 1 Run the TMC valve wire and the external...

Страница 24: ...normally open NO terminal 13 on the ETV module to the Motorized Ball Valve actuator OPEN terminal on Terminal Block F NOTE Prior to wiring of the Motorized Ball Valve actuator reference the Motorized...

Страница 25: ...l 10 on the ETV Platinum Plus b Connect the external power source wire to terminal 9 on the ETV Platinum Plus c Connect the other alarm device wire to the external power source Input Wiring CAUTION To...

Страница 26: ...hen using the Feed Forward function refer to Return Comp on page 39 The use of Probe Sensor Heat Timer p n 904222 00 is strongly recommended for the Feed Forward function 1 To connect an Auxiliary tem...

Страница 27: ...re to terminal 28 on the ETV Platinum Plus module 3 Connect the other wire to terminal 29 on the ETV Platinum Plus module Wiring the 4 20mA Remote Setpoint optional NOTE The ETV Platinum Plus does not...

Страница 28: ...odBUS interface 1 Run the ModBUS connection wires through a knockout located on the bottom of the ETV Platinum Plus enclosure 2 Connect the positive wire to terminal 30 on the ETV Platinum Plus module...

Страница 29: ...t Valve Actuator Settings and Calibration DIP Switch 1 ON DIP Switch 1 OFF The position of the Actuator Dip Switch 1 and whether the Capacitor jumper is used or removed will be determined by how the v...

Страница 30: ...059305 00 Rev D Heat Timer Corp Piping Diagrams Figure 14A Single Mixing Valve and a TMC Safety Valve 30 ETV Platinum Plus Installation and Operation Manual...

Страница 31: ...Piping Diagrams 31 059305 00 Rev D Heat Timer Corp Figure 14B Two Mixing Valves and a TMC Safety Valve...

Страница 32: ...059305 00 Rev D Heat Timer Corp Figure 14C Two Temp Application 32 ETV Platinum Plus Installation and Operation Manual...

Страница 33: ...iption Actuator Signal Indicates the change in the mixing valve opening Any time the ETV Platinum Plus changes the valve opening the LED will turn on for approximately one second If the LED remains li...

Страница 34: ...valve View the alarm logs see Alarm Log on page 50 When in the ETV TMC mode this message will alternate with the TMC Limit 160 F message 3 TMC Valve Open The system temperature is below the alarm lim...

Страница 35: ...ginal factory default settings 1 Remove power from the ETV Platinum Plus 2 Press and hold the two right most buttons on the ETV Platinum Plus while powering the control on 3 Release the buttons when i...

Страница 36: ...screens appear Follow the System Startup menu screens to program the unit Ensure the ETV module is in the PROGRAM mode see item 9 in Figure 1 on page 3 NOTE If the System Startup menu screens to not...

Страница 37: ...experiencing excessive mixed temperature This mode does not accept the Flow Prove input ETV TMC controls the electronic mixing valve to regulate the water temperature and the TMC valve and alarm to ma...

Страница 38: ...etpoint temperature as a 4 20mA signal from EMS See Wiring the 4 20mA Remote Setpoint on page 27 If Remote 4 20mA was selected the temperature range must be selected using the 4mA and 20mA settings If...

Страница 39: ...to maintain the desired setpoint temperature Selections None Aux1 Aux2 Default None Available in Control Modes ETV or ETV TMC AUX1 AUX2 Temperature Menu Path System Startup Control Mode Display Unit...

Страница 40: ...no flow is detected the control will adjust the mixing valve down to the Limit Valve POS setting if the current valve position is greater than the Limit Valve POS setting or leave the mixing valve at...

Страница 41: ...Mode Modulation Type comm options Description During startup the ETV Platinum Plus detects an installed network option If no network is detected network configuration screens are bypassed RINET Inter...

Страница 42: ...the control The date and time are used to regulate the Schedule The ETV battery is used to maintain the date and time during power outages Default Enable Selections Enable Disable Available in Control...

Страница 43: ...059305 00 Rev D Heat Timer Corp Main Menu The main Menu is used to configure setpoints TMC limits and modulating gain ETV Platinum Plus Menus TV Platinum Plus Display and Programming 43...

Страница 44: ...a schedule is set the schedule overrides the Setpoint see Schedules Menu on page 47 If the Setpoint is set to a value higher than 125 F 52 C a scald warning is displayed Select OK to acknowledge the w...

Страница 45: ...recommended to not exceed at Setpoint limit of 125 F 52 C Water drained from system drain valves may also be extremely hot Make sure all connections are tight and direct all water flow away from perso...

Страница 46: ...the gain the more aggressive the ETV Platinum Plus adjusts the mixing valve based on changes in water temperature If the water temperature tends to oscillate quickly above and below the desired setpoi...

Страница 47: ...per day Each period can have its own start time and temperature setting and will maintain that temperature setting until the next scheduled period start time NOTE Available only when Control Mode is s...

Страница 48: ...s Set SCH 1 Start Time Description Specifies the schedule start time Four Schedule Start Times can be set for each day Each start time has its own temperature setting see Set Schedule Temperature on p...

Страница 49: ...n Control Types All Menu Path Maintenance Password Enable Description When set to Yes a password must be entered in order to access the ETV Platinum Plus programming menus When enabled the password ca...

Страница 50: ...o middle buttons to scroll through the alarm list Single press the Erase button to delete the currently displayed alarm Long press at least 5 seconds the Erase button to delete all alarm entries Selec...

Страница 51: ...et Lockout Default N A Selections RESET Available in Control Modes TMC or ETV TMC Menu Path Lockout Description The TMC Lockout outputs energize whenever the System Temperature rises above the Alarm L...

Страница 52: ...sensor wiring Display shows sensor Short Defective sensor wires or ETV Platinum Plus Control Module Remove the sensor wires from the input terminals The display should read Open If the display still r...

Страница 53: ...the use of a circulation and constantly running pump Verify proper operation of the pump Check and ensure the tip of the System Sensor is in the flow stream Check and ensure the system sensor is with...

Страница 54: ...059305 00 Rev D Heat Timer Corp Notes 54 ETV Platinum Plus Installation and Operation Manual...

Страница 55: ...059305 00 Rev D Heat Timer Corp Notes ETV Platinum Plus Installation and Operation Manual 55...

Страница 56: ...ranties on behalf of such third parties Any warranty on such products or services is from the supplier manufacturer or licensor of the product or service THE FOREGOING IS IN LIEU OF ALL OTHER WARRANTI...

Отзывы: