Heat & Glo • SL-350TRS-CE-D • 2033-900 Rev. V • 3/13
35
!
OPTIONAL WALL SWITCH
THERMOSTAT OR REMOTE
REMOTE SWITCH
PIGTAIL
OFF
ON
ON/OFF
SWITCH
THERMOPILE
TP/TH
TP
TH
GAS VALVE
THERMOCOUPLE
!
Figure 52. Standing Pilot Ignition wiring Diagram
wARNING: wHEN FINISHING THE FIRE-
PLACE, NEVER OBSTRUCT OR MODIFY
THE AIR INLET/OUTLET GRILLES IN
ANY MANNER.
50
TOP FRONT EDGE
OF FIREPLACE
NOTE: ALL DIMENSIONS SHOWN
IN MILLIMETERS
76
102 127
152
158203
227
254279
305
45º
Figure 53. Minimum Vertical and Maximum Horizontal
Dimensions of Combustibles above
Fireplace
wARNING: DO NOT CONNECT 230 vAC
TO THE wALL SwITCH OR THE CON-
TROL vALvE wILL BE DESTROYED.
label all wires priOr TO DiscONNecTiON
wheN serviciNG cONTrOls. wiriNG errOrs
caN cause imprOper aND DaNGerOus Op
-
eraTiON. verify prOper OperaTiON afTer
serviciNG.
cauTiON
Step 9
Finishing
The following diagram shows the minimum vertical
and corresponding maximum horizontal dimensions
of fireplace mantels or other combustible projections
above the top front edge of the fireplace. See Figures
2, 3 and 4 for other fireplace clearances.
Only non-combustible
materials may be used
to cover the black fire-
place front.