Heat & Glo • SL-350TRS-CE-D • 2033-900 Rev. V • 3/13
33
Figure 51
The gas line should be
installed by a qualified
service technician.
!
Note: Have the gas supply line installed by a
qualified service technician in accordance with
all building regulations
.
Note: Before the first firing of the fireplace, the gas
supply
line should be purged of any trapped air.
NOTE: Consult local building regulations to
properly size the gas supply line leading to the
(Rp 1/2”) hook-up at the unit.
This gas inlet connection is ISO 7-Rp 1/2 (BSP Rp
1/2).
To install the gas supply line:
• When attaching the flue pipe, support the control
so that the lines are not bent or torn.
• After the gas line installation is complete, use a soap
solution to carefully check all gas connections for
leaks.
Step 6
The Gas
Supply Line
wARNING: DO NOT USE AN OPEN FLAME
TO CHECK FOR GAS LEAKS
.
• At the gas line access hole, use insulation to repack
the space around the gas pipe.
• Insert insulation from the outside of the fireplace and
pack the insulation tightly to totally seal between
the pipe and the outer casing.
GAS
ACCESS