A 12 Order No. BA 93-20-270 Issue 01.03.08
17
Connect the ground clamps to the workpiece as securely as possible.
Take care to ensure good contact and symmetrical connection.
The welding location must lie directly between the two ground
clamps.
3.4
Change Working Place
Switch off the power unit. In this way, you avoid any risk of
electrical shock.
When you move your workplace, disconnect the welding gun and the ground
cables from the power unit. Proceed in reversed sequence as described in
sections 3.2 and 3.3.
After changing the workplace, check the welding gun and the ground cables for
possible damage or missing components.
Содержание 93-20-270