
16
A 12 Order No. BA 93-20-270 Issue 01.03.08
Plug in the control cable of the welding gun into the appropriate connection on
the power unit.
Twist the retaining nut of the control cable connector clockwise to secure the
connection.
The welding gun cables must not be coiled during welding.
Coiled cables work as a coil and may negatively affect the
welding result. Before welding, lay out the cables lengthwise.
Fix the cables. Strong magnetic fields occur during welding which may cause a
movement of the cables. This may cause a slackness of the connections.
3.3
Ground Connection
Plug the ground cable in the connector of the power unit.
Press in the plug and twist firmly clockwise.
The connection is not secured against working itself loose!
Check the plug connections regularly to ensure that they are
properly locked. In case of loose connection, heat may build up
in the plug and may destroy the entire plug connection.
Remove any rust, paint, or contaminants from the workpiece in the areas where
you intend to connect the ground cables.
Содержание 93-20-270
Страница 1: ...A 12 Welding Gun 93 20 270 Operating Manual ...
Страница 45: ...A 12 Order No BA 93 20 270 Issue 01 03 08 45 Welding gun type A 12 93 20 270 ...
Страница 47: ...A 12 Order No BA 93 20 270 Issue 01 03 08 47 Shielding gas tripod complete A 12 93 40 021 ...
Страница 49: ...A 12 Order No BA 93 20 270 Issue 01 03 08 49 Ceramic tripod complete A 12 93 40 022 ...
Страница 61: ...A 12 Order No BA 93 20 270 Issue 01 03 08 61 Service Support ...
Страница 65: ......