Settings
TIM40
A02590_04_E00_00
HBM: public
33
12.1.7
System/Firmware update
You can update the firmware of your device via the PC. The latest firmware
(.tfw file) can be found on the HBM Internet website (www.hbm.com).
12.1.8
Transducer parameterization/Torque
You can assign a measurement point designation and measurement point
number, select the required unit, number of decimal places and the sign. You
can also activate two low‐pass filters (1 Hz to 3 KHz).
12.1.9
Transducer parameterization/Frequency output
Select the signal at the frequency output (low‐pass 1 or 2) and the required
output frequency (10
"
5 kHz; 60
"
30 kHz; 240
"
120 kHz). Specify the scaling
points with 2 values each of the torque setpoint and the frequency (only points
in the selected output range can be assigned, e.g. in the range 30,000 Hz to
90,000 Hz at output frequency 60
"
30 kHz).
1. Point
Drehmoment
Frequency
-3,000 N
@
m
30,000
90,000
2. Point
Frequency range
e.g. 60
"
30 kHz
Measuring range of torque transducer,
e.g. -3 kN
@
m to +3 kN
@
m
+3,000 N
@
m
Содержание TIM40
Страница 1: ...Mounting Instructions English TIM40...