IMPORTANT SAFETY INSTRUCTIONS

 

Before installing or servicing this electrical equipment, turn power supply OFF.   

 

 

WARNING

 – 

Hazardous Pressure.

 Pool and spa water circulation systems operate

under hazardous pressure during start-up, normal operation, and after pump shut-off. Stand

clear of circulation system equipment during pump start-up. Failure to follow safety and 

operation instructions could result in violent separation of the pump housing and cover due to

pressure in the system, which could cause property damage, severe personal injury, or death.

Before servicing pool and spa water circulation system, all system and pump controls must be 

 

in the off position and the filter manual air relief valve must be in the open position. Before starting the system pump,

all valves must be set in a position to allow system water to return back to the pool. Do not change the filter control 

valve position while the system pump is running. Before starting the system pump, fully open the filter manual air

relief valve. Do not close the filter manual air relief valve until all the air is expelled and a steady stream of water is 

discharged from the valve. All suction and discharge valves 

MUST

 be 

OPEN

 when starting the circulation system.

Failure to do so could result in severe personal injury and/or property damage.

 

 

WARNING

 –

 

Separation Hazard.

   

Failure to follow safety and operation instructions

 

could result in violent seperation of pump components. Strainer cover must be properly secured

to pump housing with strainer cover lock ring. Before servicing pool and spa circulation system, 

all system and pump controlls must be in off position and filter manual air relief valve must be in 

open position. Do not operate pool and spa circulation system if system components are not 

assembled properly, damaged, or missing. Do not operate pool and spa circulation system unless

 

filter air relief valve body is in locked position in filter upper body. All suction and discharge valves 

MUST

 be 

OPEN

 when

starting the circulation system. Failure to do so could result in severe personal injury and/or property damage.

WARNING - 

Suction Entrapment Hazard.

 Suction in suction outlets and/or 

suction outlet covers, which are damaged, broken, cracked, missing, or unsecured cause sever injury and/or

death due to the following entrapment hazards.

Hair Entrapment 

- Hair can become entangled in suction outlet cover.

Limb Entrapment

 - A limb inserted into an opening of a suction outlet sump or suction outlet cover that is

damaged, broken, cracked, missing, or not securely attached can result in a mechanical bind or swelling of

the limb.

Body Suction Entrapment

 - A differential pressure applied to a large portion of the body or limbs can

result in an entrapment.

Evisceration/Disembowelment

 - A negative pressure applied directly to the intestines through an 

unprotected suction outlet sump or suction outlet cover which is damaged, broken, cracked, missing, or 

unsecured can result in evisceration/disembowelment.

Mechanical Entrapment

 - There is potential for jewelry, swimsuits, hair decorations, fingers, toes, or

knuckles to be caught in an opening of a suction outlet cover resulting in mechanical entrapment.

WARNING - 

To Reduce the risk of Entrapment Hazards:

 

-  When outlets are small enough to be blocked by a person, a minimum of two functioning 

suction outlets per pump must be installed. Suction outlets in the same plane (i.e. floor or wall),

must be installed a minimum of 0.91 metre or three feet (3’) apart, as measured from near point

to near point to avoid duel blockage by a user.

-  Duel suction fittings shal not be located on seating areas or on the backrest for such seating

areas. 

-  Never use pool or spa if any suction outlet component is damaged, broken, cracked, missing, or not securely attached.

-  Replace damaged, broken, cracked, missing, or not securely attached suction outlet components immediately.

-  In addition to installing two or more suction outlets per pump, follow all national, state and local codes applicable.

-  Installation of a vacuum release or vent system, which relieves entrapping suction, is recommended. 

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

MaxFlo Variable Speed Pump

30-LITINSB006 Rev-B

Содержание MaxFlo VS 2300 Series

Страница 1: ...ments of today s in ground above ground swimming pool spa that is equiped with large capacity filters heaters and pool cleaning equipment The variable speed totaly enclosed permanment magnet motor com...

Страница 2: ...tructed so that it is capable of being readily disassembled for storage and reassembled to its original integrity Though this product is designed for out door use it is strongly advised to protect the...

Страница 3: ...PEN when starting the circulation system Failure to do so could result in severe personal injury and or property damage WARNING Suction Entrapment Hazard Suction in suction outlets and or suction outl...

Страница 4: ...a that will not flood when it rains Do NOT install pump and filter in a damp or non ventilated location Keep motor clean Pump motors require free circulation of air for cooling Pump Mounting Install p...

Страница 5: ...to engage the fitting an additional 1 turns Do NOT over tighten fitting or you may cause damage If a leak occurs remove the fitting and remove all traces of the sealing compound from thread Re apply...

Страница 6: ...adjustable between 600 rpm and 3000 rpm The Run Timers on speeds V2 and V3 are adjustable between 5 minutes and 18 hours in 5 minute increments Menu navigation buttons The DISP FUNC button will scrol...

Страница 7: ...ough the screens shown below in order from left to right 3 0 0 0 V1 V2 V3 Power 0 V1 V2 V3 Power P V1 V2 V3 Power P r 2 0 0 V1 V2 V3 Power 8 0 3 0 0 This is the screen that is automaticly displayed fo...

Страница 8: ...be adjusted between 5 minutes and 18 hours by pressing or holding down either or arrow button Press DISP FUNC button to advance to the next screen This screen allows the speed of V3 to be adjusted be...

Страница 9: ...pen if filter has one Turn the power on at the power point and then press the Run Stop button on the motor interface Stand back while the pump primes Due to system variances like suction lift and the...

Страница 10: ...s and chlorinators require minimum flows to operate correctly Refer to the individual equipment manuals for specific requirements for low flow operation After setting the pump speed s it is recommende...

Страница 11: ...ing a 9 16 AF spanner or socket 2 Press the ceramic seat with rubber cup out of the seal plate item 13 If tight use a small screwdriver to tap the seal out from the back side of the seal plate IMPORTA...

Страница 12: ...over O Ring Strainer Basket Pump Strainer Housing with Drain Plugs Drain Plug with O Ring Hardware Pack Includes 4 Housing Bolts Seal Plate Spacers Square Nuts Diffuser Screw 3Pack Diffuser O Ring Dif...

Страница 13: ...d union o rings on the suction side Replace damaged o rings and tighten the union nuts by hand only no wrenches Low Flow Generally 1 Check for clogged or restricted strainer basket or suction line If...

Страница 14: ...ved press the RUN STOP key to clear the error message 10 Current Measurement Fails Permanently 20 Overload During Start Up Process 64 Short Circuit Failure 97 Multiple Errors at the Same Time i e 98 C...

Страница 15: ...16 18 0 50 100 150 200 250 300 350 400 FLOW l min TDH metres 3000 RPM 2400 RPM 1500 RPM Performance curves for Hayward MaxFlo VS SP2300VS pump Page 15 30 LITINSB006 Rev B USE ONLY HAYWARD GENUINE REP...

Страница 16: ...ail sales hayward pool com au Website www hayward pool com au P O Box 4384 Dandenong South VIC 3164 ABN 66 083 413 414 Sales Ph 1300POOLS1 Fx 1300POOLS2 2015 Hayward Industries Inc Hayward and MaxFlo...

Отзывы: