Electrical - specifications

The Variable Speed Drive is fully electronic. Consisting of an integrated power module (IPM) and controller, hard and 

software with a digital signal processor (DSP). The mains inputs are supplied with a power factor correction (PFC) and 

EMC filters. The Variable Speed Drive controls a Totaly Enclosed, Fan Cooled, Permanent Magnet Motor. 

• Voltage: 220 - 240 VAC ± 10% of the mean rated voltage while running, 50Hz Single Phase

• Current: 5.9 amps

• Power (output): 1,100 W

• Speed Range: 600-3000 rpm

• Ambient temperature: 0 to 40°C

• Protection class: IP X5

All conductive parts within and around the pool shall be connected together by equipotential bonding conductors and 

connected to the protective earthing conductor of the electrical equipment as stated in AS/NZS 3000.

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

MaxFlo Variable Speed Pump

Only use Teflon tape or an elastomeric thread sealant suitable for plastic, to seal threaded connections on moulded 

plastic components. All plastic fittings must be new or thoroughly cleaned before use. 

Note

 - Do Not use Plumbers Pipe Dope or or Plumbers Putty as it may cause cracking of the plastic components.

The pump suction and outlet ports have moulded in-thread stops. Do NOT attempt to force threaded connector fitting

past this stop. It is only necessary to tighten fittings enough to prevent leakage. Tighten fitting by hand and then use a 

tool to engage the fitting an additional 1½ turns. Do NOT over-tighten fitting or you may cause damage. If a leak occurs,

remove the fitting and remove all traces of the sealing compound from thread. Re apply fresh sealing compound and 

re-install the threaded fitting.

Note

 - If the pump is being installed using the standard Hayward Universal Union that is supplied with the pump 

then there is no need to apply any type of thread sealant. The union gasket supplied is suffice to seal.

Fittings (elbows, tees, valves, ect.) restrict flow. For better efficiency use the fewest possible fittings. Avoid fittings that

could cause an air trap.

 

WARNING 

 

Risk of Electric Shock.

 All electrical wiring must be performed by a qualified electrical 

contractor, and must conform to electrical regulations and AS/NZS 3000 Wiring Rules. All electrical circuits must be 

supplied through a Residual Current Device - RCD (Safety Switch), with a residual operating current of 30mA. Hazardous 

voltage can shock, burn and cause death or serious property damage. To reduce the risk of electric shock, do NOT use 

an extension cord to connect unit to the electricity supply, or if the supply cord is damaged, it must be replaced by the

manufacture, its service agent or similarly qualified persons in order to avoid a hazard.

Plumbing

Electrical

Bonding

 

WARNING

 - 

If circulation equipment must remain in the plumbing system during water pressure test, do

 

not apply more than 68 Kpa (10psi) pressure to the system. Be sure water pressure has been released, using the filter

manual air relief valve, before removing the pump strainer cover.

30-LITINSB006 Rev-B

Содержание MaxFlo VS 2300 Series

Страница 1: ...ments of today s in ground above ground swimming pool spa that is equiped with large capacity filters heaters and pool cleaning equipment The variable speed totaly enclosed permanment magnet motor com...

Страница 2: ...tructed so that it is capable of being readily disassembled for storage and reassembled to its original integrity Though this product is designed for out door use it is strongly advised to protect the...

Страница 3: ...PEN when starting the circulation system Failure to do so could result in severe personal injury and or property damage WARNING Suction Entrapment Hazard Suction in suction outlets and or suction outl...

Страница 4: ...a that will not flood when it rains Do NOT install pump and filter in a damp or non ventilated location Keep motor clean Pump motors require free circulation of air for cooling Pump Mounting Install p...

Страница 5: ...to engage the fitting an additional 1 turns Do NOT over tighten fitting or you may cause damage If a leak occurs remove the fitting and remove all traces of the sealing compound from thread Re apply...

Страница 6: ...adjustable between 600 rpm and 3000 rpm The Run Timers on speeds V2 and V3 are adjustable between 5 minutes and 18 hours in 5 minute increments Menu navigation buttons The DISP FUNC button will scrol...

Страница 7: ...ough the screens shown below in order from left to right 3 0 0 0 V1 V2 V3 Power 0 V1 V2 V3 Power P V1 V2 V3 Power P r 2 0 0 V1 V2 V3 Power 8 0 3 0 0 This is the screen that is automaticly displayed fo...

Страница 8: ...be adjusted between 5 minutes and 18 hours by pressing or holding down either or arrow button Press DISP FUNC button to advance to the next screen This screen allows the speed of V3 to be adjusted be...

Страница 9: ...pen if filter has one Turn the power on at the power point and then press the Run Stop button on the motor interface Stand back while the pump primes Due to system variances like suction lift and the...

Страница 10: ...s and chlorinators require minimum flows to operate correctly Refer to the individual equipment manuals for specific requirements for low flow operation After setting the pump speed s it is recommende...

Страница 11: ...ing a 9 16 AF spanner or socket 2 Press the ceramic seat with rubber cup out of the seal plate item 13 If tight use a small screwdriver to tap the seal out from the back side of the seal plate IMPORTA...

Страница 12: ...over O Ring Strainer Basket Pump Strainer Housing with Drain Plugs Drain Plug with O Ring Hardware Pack Includes 4 Housing Bolts Seal Plate Spacers Square Nuts Diffuser Screw 3Pack Diffuser O Ring Dif...

Страница 13: ...d union o rings on the suction side Replace damaged o rings and tighten the union nuts by hand only no wrenches Low Flow Generally 1 Check for clogged or restricted strainer basket or suction line If...

Страница 14: ...ved press the RUN STOP key to clear the error message 10 Current Measurement Fails Permanently 20 Overload During Start Up Process 64 Short Circuit Failure 97 Multiple Errors at the Same Time i e 98 C...

Страница 15: ...16 18 0 50 100 150 200 250 300 350 400 FLOW l min TDH metres 3000 RPM 2400 RPM 1500 RPM Performance curves for Hayward MaxFlo VS SP2300VS pump Page 15 30 LITINSB006 Rev B USE ONLY HAYWARD GENUINE REP...

Страница 16: ...ail sales hayward pool com au Website www hayward pool com au P O Box 4384 Dandenong South VIC 3164 ABN 66 083 413 414 Sales Ph 1300POOLS1 Fx 1300POOLS2 2015 Hayward Industries Inc Hayward and MaxFlo...

Отзывы: