background image

Page 4

Introduction

This manual contains information for the proper installation and operation of the Hayward MaxFlo Variable Speed

Pump. The instructions in this manual MUST be followed precisely. Failure to install according to defined instructions

will void warranty. 

Installation Instructions

 

WARNING

 –

 This product should be installed and serviced only by a qualified professional.

 

Pump Location

Locate pump as close to pool as practical and run suction lines as direct as possible to reduce friction

loss. Suction lines should have continuous slope upward from lowest point in line. Joints must be tight

(but not over-tightened). Suction line must not be less than 40mm in diameter and must be equal to 

or larger in diameter than the discharge line diameter.

Though the pump is designed for outdoor use, it is advised to place pump and filter in the shade to shield them from

continuous direct heat. Select a well-drained area that will not flood when it rains. Do NOT install pump and filter in a 

damp or non-ventilated location. Keep motor clean. Pump motors require free circulation of air for cooling.

Pump Mounting

Install pump on a level concrete slab or other rigid base to meet all local and national codes. Secure pump to base

with screws or bolts to further reduce vibration and stress on pipe joints. The base must be level, rigid, and vibration free.

 

Pump mount must:

 

• Allow pump inlet height to be as close to water level as possible.

 

• Allow use of short, direct suction pipe (to reduce friction losses).

 

• Allow for valves in suction and discharge piping.

 

• Be protected from excess moisture and flooding.

 

• Allow adequate access for servicing pump and piping.

*NOTE:

 It is recommended that a minimum length of straight piping (shown as “L” in diagram to the right),

equivalent to 5 pipe size diameters, be used between the pump suction inlet and any plumbing fittings (elbows,

valves, ect).

 

 

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

MaxFlo Variable Speed Pump

Product Dimensions

*Note: All dimensions in millimetres

260

351

294

194

283

215

187

246

30-LITINSB006 Rev-B

Содержание MaxFlo VS 2300 Series

Страница 1: ...ments of today s in ground above ground swimming pool spa that is equiped with large capacity filters heaters and pool cleaning equipment The variable speed totaly enclosed permanment magnet motor com...

Страница 2: ...tructed so that it is capable of being readily disassembled for storage and reassembled to its original integrity Though this product is designed for out door use it is strongly advised to protect the...

Страница 3: ...PEN when starting the circulation system Failure to do so could result in severe personal injury and or property damage WARNING Suction Entrapment Hazard Suction in suction outlets and or suction outl...

Страница 4: ...a that will not flood when it rains Do NOT install pump and filter in a damp or non ventilated location Keep motor clean Pump motors require free circulation of air for cooling Pump Mounting Install p...

Страница 5: ...to engage the fitting an additional 1 turns Do NOT over tighten fitting or you may cause damage If a leak occurs remove the fitting and remove all traces of the sealing compound from thread Re apply...

Страница 6: ...adjustable between 600 rpm and 3000 rpm The Run Timers on speeds V2 and V3 are adjustable between 5 minutes and 18 hours in 5 minute increments Menu navigation buttons The DISP FUNC button will scrol...

Страница 7: ...ough the screens shown below in order from left to right 3 0 0 0 V1 V2 V3 Power 0 V1 V2 V3 Power P V1 V2 V3 Power P r 2 0 0 V1 V2 V3 Power 8 0 3 0 0 This is the screen that is automaticly displayed fo...

Страница 8: ...be adjusted between 5 minutes and 18 hours by pressing or holding down either or arrow button Press DISP FUNC button to advance to the next screen This screen allows the speed of V3 to be adjusted be...

Страница 9: ...pen if filter has one Turn the power on at the power point and then press the Run Stop button on the motor interface Stand back while the pump primes Due to system variances like suction lift and the...

Страница 10: ...s and chlorinators require minimum flows to operate correctly Refer to the individual equipment manuals for specific requirements for low flow operation After setting the pump speed s it is recommende...

Страница 11: ...ing a 9 16 AF spanner or socket 2 Press the ceramic seat with rubber cup out of the seal plate item 13 If tight use a small screwdriver to tap the seal out from the back side of the seal plate IMPORTA...

Страница 12: ...over O Ring Strainer Basket Pump Strainer Housing with Drain Plugs Drain Plug with O Ring Hardware Pack Includes 4 Housing Bolts Seal Plate Spacers Square Nuts Diffuser Screw 3Pack Diffuser O Ring Dif...

Страница 13: ...d union o rings on the suction side Replace damaged o rings and tighten the union nuts by hand only no wrenches Low Flow Generally 1 Check for clogged or restricted strainer basket or suction line If...

Страница 14: ...ved press the RUN STOP key to clear the error message 10 Current Measurement Fails Permanently 20 Overload During Start Up Process 64 Short Circuit Failure 97 Multiple Errors at the Same Time i e 98 C...

Страница 15: ...16 18 0 50 100 150 200 250 300 350 400 FLOW l min TDH metres 3000 RPM 2400 RPM 1500 RPM Performance curves for Hayward MaxFlo VS SP2300VS pump Page 15 30 LITINSB006 Rev B USE ONLY HAYWARD GENUINE REP...

Страница 16: ...ail sales hayward pool com au Website www hayward pool com au P O Box 4384 Dandenong South VIC 3164 ABN 66 083 413 414 Sales Ph 1300POOLS1 Fx 1300POOLS2 2015 Hayward Industries Inc Hayward and MaxFlo...

Отзывы: