Page 12

MaxFlo VS Pump - Replacement Parts

Parts Diagram

Parts Listing

Ref. No.

1
2
3
4
5
6
7
8
9

10
11
12
13
14
15
16
17

18

--
--
--

Part No.

SPX2300DLS
SPX2300Z4
SPX2300M
SPX2300AA
SPX4000FG
SPX2700ZPAK
SPX2300Z3PAK3
SX220Z2
SPX2300B
SPX2300CVS
GMX600F
SPX2700SA
SPX2300E
SPX3200Z5PAK4
SPX2300G
SPX1600Z52
SPX2700UNKIT
SPX3200UNKIT
SPX2300GR
SPX3200UG
SPX2300VSM
SPX0327

Description

Strainer Cover Kit (Includes Strainer Cover, Lock-Ring, O-Ring)
Strainer Cover O-Ring
Strainer Basket
Pump Strainer Housing with Drain Plugs
Drain Plug with O-Ring
Hardware Pack (Includes 4 Housing Bolts, Seal Plate Spacers & Square Nuts)
Diffuser Screw (3Pack)
Diffuser O-Ring
Diffuser
Impeller 
Housing O-Ring
Shaft Seal Assembly
Seal Plate
Motor Bolt (4 Pack)
Motor Support with Base Mount Screws
Motor Support Base Mount Screws (2 Pack)
Union Connector Kit suits 40mm PVC pipe (Inc’d 2 Nuts, Connectors, Gaskets)
Union Connector Kit suits 50mm PVC pipe (Inc’d 2 Nuts, Connectors, Gaskets) 
Optional Riser Base 
Union Gasket  - Not shown
Motor, suit SP2300VS
“Jack’s formula 327 Multilube” Silicone lube for O-Rings - 1 ounce (28 gram) tube

Qty. Req’d

1
1
1
1
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
1
1

30-LITINSB006 Rev-B

Содержание MaxFlo VS 2300 Series

Страница 1: ...ments of today s in ground above ground swimming pool spa that is equiped with large capacity filters heaters and pool cleaning equipment The variable speed totaly enclosed permanment magnet motor com...

Страница 2: ...tructed so that it is capable of being readily disassembled for storage and reassembled to its original integrity Though this product is designed for out door use it is strongly advised to protect the...

Страница 3: ...PEN when starting the circulation system Failure to do so could result in severe personal injury and or property damage WARNING Suction Entrapment Hazard Suction in suction outlets and or suction outl...

Страница 4: ...a that will not flood when it rains Do NOT install pump and filter in a damp or non ventilated location Keep motor clean Pump motors require free circulation of air for cooling Pump Mounting Install p...

Страница 5: ...to engage the fitting an additional 1 turns Do NOT over tighten fitting or you may cause damage If a leak occurs remove the fitting and remove all traces of the sealing compound from thread Re apply...

Страница 6: ...adjustable between 600 rpm and 3000 rpm The Run Timers on speeds V2 and V3 are adjustable between 5 minutes and 18 hours in 5 minute increments Menu navigation buttons The DISP FUNC button will scrol...

Страница 7: ...ough the screens shown below in order from left to right 3 0 0 0 V1 V2 V3 Power 0 V1 V2 V3 Power P V1 V2 V3 Power P r 2 0 0 V1 V2 V3 Power 8 0 3 0 0 This is the screen that is automaticly displayed fo...

Страница 8: ...be adjusted between 5 minutes and 18 hours by pressing or holding down either or arrow button Press DISP FUNC button to advance to the next screen This screen allows the speed of V3 to be adjusted be...

Страница 9: ...pen if filter has one Turn the power on at the power point and then press the Run Stop button on the motor interface Stand back while the pump primes Due to system variances like suction lift and the...

Страница 10: ...s and chlorinators require minimum flows to operate correctly Refer to the individual equipment manuals for specific requirements for low flow operation After setting the pump speed s it is recommende...

Страница 11: ...ing a 9 16 AF spanner or socket 2 Press the ceramic seat with rubber cup out of the seal plate item 13 If tight use a small screwdriver to tap the seal out from the back side of the seal plate IMPORTA...

Страница 12: ...over O Ring Strainer Basket Pump Strainer Housing with Drain Plugs Drain Plug with O Ring Hardware Pack Includes 4 Housing Bolts Seal Plate Spacers Square Nuts Diffuser Screw 3Pack Diffuser O Ring Dif...

Страница 13: ...d union o rings on the suction side Replace damaged o rings and tighten the union nuts by hand only no wrenches Low Flow Generally 1 Check for clogged or restricted strainer basket or suction line If...

Страница 14: ...ved press the RUN STOP key to clear the error message 10 Current Measurement Fails Permanently 20 Overload During Start Up Process 64 Short Circuit Failure 97 Multiple Errors at the Same Time i e 98 C...