background image

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

MaxFlo Variable Speed Pump

Page 6

 

 

 

  

 

User Interface Overview

 

 

The User Interface is equipped with a membrane keyboard and a digital display with five 7-segment digits. 

 

30-LITINSB004 Rev-B

Preset Speeds

Buttons labeled V1 through V3 can be used to run the pump at a predetermined speed for a certain length of time. Preset

Speed settings can be quickly updated using the    and    arrow buttons to change the speed and then pressing both

    and    arrow buttons simultaneously to save the new speed setting. When a speed is selected, the LED beside the 

button will illuminate to indicate operation.

    

Start Up

This pump is factory set to start in prime mode for two minutes. When Priming has finished the pump will then switch to

speed V3. The pump will run at this speed (adjustable) for its programmed time (adjustable) then switch to speed V1.

The pump will then remain at speed V1 until power is cycled or another speed is selected.

Factory Default Speeds and Run Times

•  Prime Mode: 3000 rpm / 2 minute duration

•  V1: 1450 rpm

•  V2: 2400 rpm / 4 hour duration

•  V3: 3000 rpm / 5 minute duration

Note:

 The duration of the Prime Mode is adjustable between 0 minutes and 4 minutes. If adjusted to zero the Prime 

Mode is disabled and the pump will start in speed V3. The speed of the Prime Mode is non-adjustable.

Speeds V1 through V3 are adjustable between 600 rpm and 3000 rpm. The Run Timers on speeds V2 and V3 are 

adjustable between 5 minutes and 18 hours in 5 minute increments. 

Menu / navigation buttons

The DISP/FUNC button will scroll through the home screen information when pressed. If the DISP/FUNC button is held

it will enter the controller into 

configuration mode.

 The    and    arrow buttons are used to change parameters within

configuration mode.

Power LED

The Power LED will remain illuminated while the unit has power unless the pump is experiencing an error. When the 

pump experiences an error the 

Power LED will “FLASH”

 and a code will be displayed

.

 

Run / Stop

This button is used to stop the pump to allow strainer basket cleaning, etc. When this button is pressed the pump will

remain stopped and the remaining time for the current speed will be paused untill the the button is pressed a second 

time to resume normal operation.

Configuration Menu Outline
a.

  

Prime Mode

 run time - default 2 minutes / range 0 - 4 minutes in 1 second increments;

b.

  

V1 Speed

 - default 1450 rpm / range 600 - 3000 rpm in 10 rpm increments;

c.

  

V2 Speed

 - default 2400 rpm / range 600 - 3000 rpm in 10 rpm increments;

e.

  

V2 Timer

 - default 4 hours / range 5 minutes - 18 hours in 5 minute increments;

f. 

  

V3 Speed

 - default 3000 rpm / range 600 - 3000 rpm in 10 rpm increments;

g.

  

V3 Timer

 - default 5 minutes / range 5 minutes - 18 hours in 5 minute increments;

Note: 

Scroll through a - g using 

DISP/FUNC

 button and adjust each parameter using the    and    arrow buttons. 

          

Holding the arrow buttons down will enable fast scrolling of the values.

Содержание MaxFlo VS 2300 Series

Страница 1: ...ments of today s in ground above ground swimming pool spa that is equiped with large capacity filters heaters and pool cleaning equipment The variable speed totaly enclosed permanment magnet motor com...

Страница 2: ...tructed so that it is capable of being readily disassembled for storage and reassembled to its original integrity Though this product is designed for out door use it is strongly advised to protect the...

Страница 3: ...PEN when starting the circulation system Failure to do so could result in severe personal injury and or property damage WARNING Suction Entrapment Hazard Suction in suction outlets and or suction outl...

Страница 4: ...a that will not flood when it rains Do NOT install pump and filter in a damp or non ventilated location Keep motor clean Pump motors require free circulation of air for cooling Pump Mounting Install p...

Страница 5: ...to engage the fitting an additional 1 turns Do NOT over tighten fitting or you may cause damage If a leak occurs remove the fitting and remove all traces of the sealing compound from thread Re apply...

Страница 6: ...adjustable between 600 rpm and 3000 rpm The Run Timers on speeds V2 and V3 are adjustable between 5 minutes and 18 hours in 5 minute increments Menu navigation buttons The DISP FUNC button will scrol...

Страница 7: ...ough the screens shown below in order from left to right 3 0 0 0 V1 V2 V3 Power 0 V1 V2 V3 Power P V1 V2 V3 Power P r 2 0 0 V1 V2 V3 Power 8 0 3 0 0 This is the screen that is automaticly displayed fo...

Страница 8: ...be adjusted between 5 minutes and 18 hours by pressing or holding down either or arrow button Press DISP FUNC button to advance to the next screen This screen allows the speed of V3 to be adjusted be...

Страница 9: ...pen if filter has one Turn the power on at the power point and then press the Run Stop button on the motor interface Stand back while the pump primes Due to system variances like suction lift and the...

Страница 10: ...s and chlorinators require minimum flows to operate correctly Refer to the individual equipment manuals for specific requirements for low flow operation After setting the pump speed s it is recommende...

Страница 11: ...ing a 9 16 AF spanner or socket 2 Press the ceramic seat with rubber cup out of the seal plate item 13 If tight use a small screwdriver to tap the seal out from the back side of the seal plate IMPORTA...

Страница 12: ...over O Ring Strainer Basket Pump Strainer Housing with Drain Plugs Drain Plug with O Ring Hardware Pack Includes 4 Housing Bolts Seal Plate Spacers Square Nuts Diffuser Screw 3Pack Diffuser O Ring Dif...

Страница 13: ...d union o rings on the suction side Replace damaged o rings and tighten the union nuts by hand only no wrenches Low Flow Generally 1 Check for clogged or restricted strainer basket or suction line If...

Страница 14: ...ved press the RUN STOP key to clear the error message 10 Current Measurement Fails Permanently 20 Overload During Start Up Process 64 Short Circuit Failure 97 Multiple Errors at the Same Time i e 98 C...

Страница 15: ...16 18 0 50 100 150 200 250 300 350 400 FLOW l min TDH metres 3000 RPM 2400 RPM 1500 RPM Performance curves for Hayward MaxFlo VS SP2300VS pump Page 15 30 LITINSB006 Rev B USE ONLY HAYWARD GENUINE REP...

Страница 16: ...ail sales hayward pool com au Website www hayward pool com au P O Box 4384 Dandenong South VIC 3164 ABN 66 083 413 414 Sales Ph 1300POOLS1 Fx 1300POOLS2 2015 Hayward Industries Inc Hayward and MaxFlo...

Отзывы: