background image

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

MaxFlo Variable Speed Pump

Page 11

Shaft Seal Change Instructions

IMPORTANT SAFETY INSTRUCTIONS

PLEASE READ AND FOLLOW ALL INSTRUCTIONS

When servicing electrical equipment, basic safety precautions should always be observed including the following.

Failure to follow the instructions may result in injury.

 

• Disconnect the pump motor power cord from the power outlet before beginning the shaft seal replacement.

 

• Only qualified personnel should attempt to replace the shaft seal. Contact your local authorized Hayward Dealer 

              or service center if you have any questions.

 

• Exercise extreme care in handling both the rotating and stationary sections of the two-part replacement seal.

              Foreign matter or improper handling will easily scratch the graphite and ceramic sealing surfaces.

 

• See the “Parts Diagram” on page twelve (12) for the pump component locations.

Removing the Motor Assembly

1. Remove the four (4) 5/16” x 1.75” hex head bolts (Item #6), which hold the motor assembly to the pump/strainer 

    housing (item #4), using a 1/2” AF spanner or socket.

2. Slide the motor assembly out of the pump/strainer housing (item 4), exposing the diffuser (item 9). Remove the

    three (3) diffuser screws (item #7), and pull the diffuser (item #9) off the seal plate (item #13) to expose the impeller

    (item #10).

Removing the Impeller

1. To prevent the motor shaft from turning, insert a 6mm Allen Key through the center hole in the fan cowling and into 

    the socket on the end of the motor shaft.

2. Remove the impeller (item #10) by rotating it counterclockwise.

Removing the Ceramic Seat

1. Remove the spring seal assembly (item #12) and seal plate (item #13) from the motor by removing the four (4) 3/8”

    x 1” bolts (item #14) that secure it to the motor, using a 9/16” AF spanner or socket. 

2. Press the ceramic seat with rubber cup out of the seal plate (item #13). If tight, use a small screwdriver to tap the seal

    out from the back side of the seal plate.

IMPORTANT -

Clean all recesses and parts to be reassembled. Inspect gaskets and replace if necessary.

Seal, Impeller, and Diffuser Installation

1. Clean and lightly lubricate the motor shaft and seal recess in the seal plate (item #13) with a dilute solution of non

    granulated liquid type soap. Gently wipe the polished face of the ceramic seal with a soft, lint free cotten cloth.

    Lubricate the rubber cup on the ceramic seat and press it firmly into the recess of the seal plate (item #13), with the

    polished ceramic surface facing towards you.

2. Reassemble the motor to the seal plate (item #13) using the four (4) 3/8” x 1” bolts (item #14) by tightening them in

    a cross pattern and torque to 11.5 N-m. Ensure there is equal clearence between the motor shaft and ceramic seat. 

3. Gently wipe the black, polished surface of the carbon spring seal assembly (item #12) with a soft, lint free cotton cloth.

4. Press the carbon spring seal assembly (item #12) onto the motor shaft, with the black polished surface facing the

    ceramic seat.

5. Screw the impeller (item #10) onto the motor shaft in a clockwise direction and tightn snugly by holding the motor

    shaft with the 6mm Allen Key as explained earlier.  

6. Place the diffuser (item #9) over the impeller (item #10) and onto the seal plate (item #13), aligning the three (3) 

    pins on the diffuser (item #9) with the three (3) holes on the seal plate (item #13). Note: Flat side of diffuser rim will

    face up. Replace the three (3) diffuser screws (item #7) and torque to 2.3 N-m.

7. Replace the motor Assembly into the pump/strainer housing in the reverse order of the removal steps. Ensure the 

    housing gasket (item #11) is lubricated and tighten the housing bolts (item #6) in a cross pattern evenly and to a

    torque of 21 Newton Meters.   

30-LITINSB006 Rev-B

Содержание MaxFlo VS 2300 Series

Страница 1: ...ments of today s in ground above ground swimming pool spa that is equiped with large capacity filters heaters and pool cleaning equipment The variable speed totaly enclosed permanment magnet motor com...

Страница 2: ...tructed so that it is capable of being readily disassembled for storage and reassembled to its original integrity Though this product is designed for out door use it is strongly advised to protect the...

Страница 3: ...PEN when starting the circulation system Failure to do so could result in severe personal injury and or property damage WARNING Suction Entrapment Hazard Suction in suction outlets and or suction outl...

Страница 4: ...a that will not flood when it rains Do NOT install pump and filter in a damp or non ventilated location Keep motor clean Pump motors require free circulation of air for cooling Pump Mounting Install p...

Страница 5: ...to engage the fitting an additional 1 turns Do NOT over tighten fitting or you may cause damage If a leak occurs remove the fitting and remove all traces of the sealing compound from thread Re apply...

Страница 6: ...adjustable between 600 rpm and 3000 rpm The Run Timers on speeds V2 and V3 are adjustable between 5 minutes and 18 hours in 5 minute increments Menu navigation buttons The DISP FUNC button will scrol...

Страница 7: ...ough the screens shown below in order from left to right 3 0 0 0 V1 V2 V3 Power 0 V1 V2 V3 Power P V1 V2 V3 Power P r 2 0 0 V1 V2 V3 Power 8 0 3 0 0 This is the screen that is automaticly displayed fo...

Страница 8: ...be adjusted between 5 minutes and 18 hours by pressing or holding down either or arrow button Press DISP FUNC button to advance to the next screen This screen allows the speed of V3 to be adjusted be...

Страница 9: ...pen if filter has one Turn the power on at the power point and then press the Run Stop button on the motor interface Stand back while the pump primes Due to system variances like suction lift and the...

Страница 10: ...s and chlorinators require minimum flows to operate correctly Refer to the individual equipment manuals for specific requirements for low flow operation After setting the pump speed s it is recommende...

Страница 11: ...ing a 9 16 AF spanner or socket 2 Press the ceramic seat with rubber cup out of the seal plate item 13 If tight use a small screwdriver to tap the seal out from the back side of the seal plate IMPORTA...

Страница 12: ...over O Ring Strainer Basket Pump Strainer Housing with Drain Plugs Drain Plug with O Ring Hardware Pack Includes 4 Housing Bolts Seal Plate Spacers Square Nuts Diffuser Screw 3Pack Diffuser O Ring Dif...

Страница 13: ...d union o rings on the suction side Replace damaged o rings and tighten the union nuts by hand only no wrenches Low Flow Generally 1 Check for clogged or restricted strainer basket or suction line If...

Страница 14: ...ved press the RUN STOP key to clear the error message 10 Current Measurement Fails Permanently 20 Overload During Start Up Process 64 Short Circuit Failure 97 Multiple Errors at the Same Time i e 98 C...

Страница 15: ...16 18 0 50 100 150 200 250 300 350 400 FLOW l min TDH metres 3000 RPM 2400 RPM 1500 RPM Performance curves for Hayward MaxFlo VS SP2300VS pump Page 15 30 LITINSB006 Rev B USE ONLY HAYWARD GENUINE REP...

Страница 16: ...ail sales hayward pool com au Website www hayward pool com au P O Box 4384 Dandenong South VIC 3164 ABN 66 083 413 414 Sales Ph 1300POOLS1 Fx 1300POOLS2 2015 Hayward Industries Inc Hayward and MaxFlo...