1. The suction line should be installed as short and straight as possible, with a minimum of bends. The internal diameter of the suction pipe must be 

    equal to, or greater than the ports of the pump.

2. For suction lift over 4 meters, the suction pipe should be of greater diameter than the suction port. 
3. The protective rubber films within the center of the suction/discharge flange gaskets must be removed before installation. 
4. Be careful not to allow any foreign objects (PVC adhesive gum, dirt, sand etc.) into the pump, otherwise the pump will not operate correctly. To  

    prevent this problem, it is recommended to use a strainer which already comes with the product. 

These pumps are designed for the pumping of non-aggressive water, or water not containing solid particles. 

LIQUIDS TO BE PUMPED 

2. It is recommended that the plumber/installer provides an adequate draining system to avoid damage in case of leakage, particularly when  
    installed indoors. When it is installed outside, it should be covered by a weather-proof housing, well ventilated to allow motor heat to escape.  
3. The pump should be installed as close as possible to the water source. 
4. When use with water heaters, a check valve should be installed between pump (discharge) pipeline and water heater to avoid high-pressure steam  
    backflow. Besides, negative inlet pressure application is required to avoid cavitation.  
6. It is recommended to shut off the pump when the water source is unavailable; although it has the dry run cut off function.  
7. The pump has a built-in check valve. It is not necessary install any other valve on the suction. 
8. To avoid your furniture damage, do not install the pump on ceiling, carpet or any place close to electrical appliance, outdoor installation must covered by tent.

1. The pump foundation should be rigid enough to absorb any vibration from the motor, and the pump should be securely bolted to the foundation. 

Ambient temp.    : Max. +40ºC (104ºF) for cold water series Max. +90ºC (194ºF) for hot water series  

Water temp.        : +2ºC (36ºF) ~ +40ºC (104ºF)

Water pH range  : 5.5 ~ 8.5 

System pressure  : SSA200W,300W,400W Max. 5 kg/cm² (70 PSI)  SSA600W,800W Max. 7 kg/cm² (99 PSI) 

Relative humidity: Max. 85% (RH)

OPERATING CONDITIONS

INSTALLATION

PIPING

CCAAPB0E02

Installation and 

Operating 

Instructions

SSA  Series

DEAR CLIENT, 

   Congratulations  on your purchase of this product.  Like all Our

products, we had developed it with the latest technologies and produced it 

with the most advanced manufacturing process and the best quality parts. 

Please do read all instructions carefully before installing your new product, 

as failures caused by incorrect installation or operation are not covered by 

the warranty. 

TROUBLESHOOTING

Before starting work on the pump, make sure that the electricity supply has been switched off and that it cannot be accidentally switched on.

*If your problem can not be fixed by the suggested remedy, please contact your pump supplier. 

Problem

4. Pump starts 

    and stops too 

    frequently

5. Electric shock
6. Pump does 

    not stop when 

    water is not 

    consumed

7. Pump runs 

    normal but 

    with very low 

    discharge flow

Cause

a. Leakage in suction 

    pipe or air in the water.

b. Discharge flow is too low.

a. Ineffective grounding
a. Poor water supply or 

    air suck in.

b. Pressure setting is too 

    high
c. Existing pipe is leaking Fix the leakage.

a. 3-phase motor runs in 

    wrong rotation.
b. Poor water supply

Remedy

Check the suction pipe and water supply

Set your tap on a higher water flow.
Reactivate grounding.
1. Turn off the power supply and open 

    the refilling plug to release the air. 

    Then restart.
2. In case of long suction pipes, turn off 

    the power and make sure if water 

    supply is adequate.
Adjust pressure per "ADJUST 

PRESSURE SWITCH" in the Manual.

Switch any of the 2 wires from motor 

terminal to correct rotation.
Check if water supply is adequate and if 

the inlet pipe is blocked.

Problem

1. pump does 

    not start

2. Pump cuts 

    out during 

    operation 

3. Pump starts 

    when no 

    water is 

    consumed

Cause

a. No power supply
b. Wrong voltage
c. Inadequate pressure 

    setting
d. Seized-up pump

a. Seized-up pump

b. Overloaded/

    overheated motor

c. Poor water supply

a. Existing pipe is leaking
b. Defective check valve 
c. Pump suck in air.

Remedy

Connect the electricity supply
Check if supply voltage is correct.
Adjust pressure per "ADJUST PRESSURE 

SWITCH" in the Manual.
Place a screwdriver against the shaft end 

of the motor to check it the rotor will spin

freely, and contact your pump supplier.

Same as above

The pump will start after motor cooling 

down. If it doesn’t, or the problem 

happens too frequently, please contact 

your pump supplier.

Check if water supply is adequate and 

if the inlet pipe is blocked.

Fix the leakage.
Clean or replace with a new valve.
Check the suction pipe and water supply.

This Product is warranted to the first user only to be free of defects in material and workmanship for a period of 12 months from date of  

installation, but no more than 18 months from date of manufacture. Our liability under this warranty shall be limited to repairing or  

replacing at our election, without charge, FOB Our distribution center or authorised service agent. We will not   be liable for any cost

of removal, installation, transportation or any other charges that may arise in connection with warranty claim. 

The warranty period commences on the date of original purchase of the equipment. Proof of purchase and installation date, failure date, and 

supporting installation data must be provided when claiming repairs under warranty.

 
This warranty is subject to due compliance by the original purchaser  with all directions and conditions set out in the installation and operating

instructions. Failure to comply with these instructions, damage or  breakdown caused by fair wear and tear, negligence, misuse, incorrect 

installation, inappropriate chemicals or additives in the water, inadequate protection against freezing, rain or other adverse weather conditions, 

corrosive or abrasive water, lightning or high voltage spikes or through unauthorised persons attempting repairs are not covered under warranty.

We will not be liable for any incidental or consequential  damages, losses, or expenses, arising from installation, use, or any other causes. 

There are no express or implied warranties, including merchantability or fitness for a particular purpose, which extend beyond those 

warranties described or referred to above.

Certain countries do not permit the exclusion or limitation of incidental or consequential damages or the placing of limitations on the duration of

an implied warranty, therefore, the limitations or exclusions herein may not apply. This warranty sets forth specific legal rights and obligations, 

however, additional rights may exist, which may vary from country to country.

Supersedes all previous publications.

Limited Warranty:

STAIRS INDUSTRIAL CO., LTD

No. 3-8,Sanchial Tsun, Lutsao Husiang, Chiayi Hsien, Taiwan

Tel: +886 5 3750488   Fax: +886 5 3752330

E-mail: [email protected]   Web Page: www.stairs.com.tw 

Отзывы: