MODEL 9035 GENERAL ASSEMBLY NOTES
Unless otherwise specified: All PIPES must be fully engaged into floor flanges and fittings. On parts where there
are no internal stopping features, pipe ends will terminate at intersecting pipe surfaces or where they run out.
Full engagement of the pipes is critical to the overall size and shape of the unit and to the correct alignment of
all fittings, loop clamps and panels.
All FITTINGS must be oriented such that their mounting screw bosses (Hex Set Screws are included with all
fittings) face toward the inside of the unit. This allows the shelter cover panels to rest close to the frame and to
mate flush with the panel mounting loop clamps. Mounting screws in the 90º Short Elbows should face upward
for best tool access.
All SET SCREWS must be fastened in place using thread-locker (not supplied). However, it may become
necessary to re-align fittings and pipes prior to locking the set screws. Apply thread-locker sparingly at first, to
allow for final adjustment and, when final alignment is ascertained, sufficiently coat all screws and lock in place.
9035 SHOWER SHELTER / FINAL ASSEMBLY PREVIEW
FIGURE 1