hd 680 DEI-V
ValiDoc Pro
Page GB 16
9.693.018
Version 1.06
3.2.1 Important note regarding the sealing process
The material to be sealed must be sealed according to the manufacturer's instructions.
Set the peel edge width:
After releasing the locking device, the peel edge can be steplessly adjusted by between
0 mm and 35 mm by moving the infeed section. Sufficient overhang must be present
between the sealing seam and the reel interface on the extraction side.
Sterilisation packaging must be inserted from the left-hand side, always with the paper side
face down.
The drive is switched on automatically.
Remove the sealed sterilisation packaging and leave briefly to cool.
Sealable pouches and reels must only be filled to ¾ full. The limited filling prevents
too great a load being placed on the sealing seams.
The correct sealing temperature must be identified by means of sealing tests.
Sealing must be performed in such a way that the sealing seam meets the quality
characteristics required in EN ISO 11607-2, even with varying material
thicknesses. The following quality characteristics must be met:
Intact sealing across the entire sealing seam width
No channels or open seals
No punctures or tears
No delamination or material separation
The hawotest SEAL CHECK is considered to be suitable for checking the quality
criteria. The hawotest SEAL CHECK seal indicators are available separately.