hd 680 DEI-V
ValiDoc Pro
Page GB 56
9.693.018
Version 1.06
5.5 Adjusting the process parameters
After adjusting, the machine must remain switched on for another 10 seconds!
5.5.1
Temperature control
Adjustment of temperature
control must always be
performed after replacing a
heating cartridge, after
replacing the temperature
sensor and after replacing the
temperature controller.
The temperatures
120°C and 200°C
are measured one after another
and the difference between the set value and the actual value is
corrected.
After a set temperature has been reached it is stabilised for 120s.
After the 120 seconds have elapsed, the measured temperature value
is entered using the temperature measuring instrument
Procedure
Insert the temperature measuring instrument's sensor between
the sealing dies from the left infeed side
Press both buttons at the same time and switch on the machine
Power switch