CHARGING
80% CHARGED
CHECK BATTERY
Linear Battery Charger
CHARGE CURRENT
PUSH
FOR
BATTERY VOLTAGE
FUSE 15A
SLO BLO
BATTERY RECHARGE
Recharge aerial work platform batteries after each 8-hour work shift or as needed. When using the
gas engine, press (push) the
GENERATOR
(4)
button on the platform (upper) control panel to charge
the batteries. When the aerial work platform is not in use, batteries should be recharged at least
once per week. Under normal circumstances, battery recharge should take approximately 10-12
hours. However, a full recharge may take up to 24 hours, if the battery charge is extremely low.
To recharge the aerial work platform batteries:
Move the aerial work platform to a well-ventilated area with direct access to an AC electrical
outlet. Keep the aerial work platform and batteries away from open flame or other potential
ignition sources.
Attach a 12 AWG multi-strand, grounded
EXTENSION CORD
with a maximum length of 50 feet (15
meters) to the receptacle located inside the
ENGINE COMPARTMENT
. The generator may need to
be disconnected from the receptacle prior to connecting the extension cord.
NOTE: Using an underrated or long power cord will reduce the output of the battery charger
and may extend charge time.
Plug
the
EXTENSION CORD
into outlet. Verify that the
GREEN CHARGING
indicator
LED
is lit on the
BATTERY CHARGER FACEPLATE
. Refer to Figure 4-1.
The charging indicator
LED
remains lit continuously during the first stage of the charge cycle.
The charge current will be displayed on the
BATTERY CHARGER FACEPLATE
.
To display the Battery Voltage, press (push) in and hold the
BATTERY VOLTAGE
button.
Refer to Figure 4-1.
Figure 4-1. Battery Charger Faceplate
WARNING
Recharge batteries in a well-ventilated area only. DO NOT
charge batteries near fire, spark or other potential ignition
sources. Batteries may emit highly explosive Hydrogen
gas while charging. Failure to properly ventilate the
charge gasses could result in death or serious injury.
Always charge aerial work platform batteries away from
flammable materials.
Содержание xlb-4725a
Страница 1: ...OPERATOR S MAINTENANCE MANUAL B33 01 0104 Rev 4 August 2012...
Страница 70: ...HAULOTTE GROUP 5 CYLINDER REPLACEMENT 70...
Страница 78: ...HAULOTTE GROUP 6 DECAL REPLACEMENT 78 DECAL KIT ANSI...
Страница 80: ...HAULOTTE GROUP 6 DECAL REPLACEMENT 80 IDENTIFICATION PLATES OPTIONAL EQUIPMENT ANSI...
Страница 86: ...HAULOTTE GROUP 6 DECAL REPLACEMENT 86...
Страница 92: ...HAULOTTE GROUP 7 OPTIONAL EQUIPMENT 92...
Страница 98: ...HAULOTTE GROUP 8 MATERIAL SAFETY 98 MATERIAL SAFETY DATA SHEET POWERFLOW AW HVI HYDRAULIC OIL...
Страница 99: ...HAULOTTE GROUP 8 MATERIAL SAFETY 99 MATERIAL SAFETY DATA SHEET POWERFLOW AW HVI HYDRAULIC OIL CONTINUED...
Страница 100: ...HAULOTTE GROUP 8 MATERIAL SAFETY 100 MATERIAL SAFETY DATA SHEET POWERFLOW AW HVI HYDRAULIC OIL CONTINUED...
Страница 101: ...HAULOTTE GROUP 8 MATERIAL SAFETY 101 MATERIAL SAFETY DATA SHEET POWERFLOW AW HVI HYDRAULIC OIL CONTINUED...
Страница 102: ...HAULOTTE GROUP 8 MATERIAL SAFETY 102 MATERIAL SAFETY DATA SHEET POWERFLOW AW HVI HYDRAULIC OIL CONTINUED...
Страница 103: ...HAULOTTE GROUP 8 MATERIAL SAFETY 103 MATERIAL SAFETY DATA SHEET POWERFLOW AW HVI HYDRAULIC OIL CONTINUED...
Страница 104: ...HAULOTTE GROUP 8 MATERIAL SAFETY 104 MATERIAL SAFETY DATA SHEET POWERFLOW AW HVI HYDRAULIC OIL CONTINUED...
Страница 116: ...HAULOTTE GROUP 9 ANSI REPRINT 116...