background image

 

 

 

 

EN 

 

 

2. SAUNA ROOM 

 

2.1. Sauna Room Structure (figure 4) 

 

 

 

 

 

 

 

 

 CZ 

 
 

2. SAUNA 

 

2.1. Stavba sauny ( obr. 4 ) 
 

 

 

 

 

 

 
 

 

 

 

 
 

Figure 4. 
0brazek 4. 

 

A. Insulation wool, thickness 50–100 mm. The 

sauna room must be insulated carefully so that 
the heater output can be kept moderately low. 

B. Moisture protection, e.g. aluminium paper. 

Place the glossy side of the paper towards the 
sauna. Tape the seams with aluminium tape. 

C. Vent gap of about 10 mm between the mois- 

ture protection and panel (recommendation). 

D. Low mass 12–16 mm thick panel board. Before 

starting the panelling, check the electric wiring 
and the reinforcements in the walls required by 
the heater and benches. 

E. Vent gap of about 3 mm between the wall and 

ceiling panel. 

F. The height of the sauna is usually 2100–2300 mm. 

The minimum height depends on the heater (see 
table 3). The space between the upper bench 
and ceiling should not exceed 1200 mm. 

G. Use floor coverings made of ceramic materials 

and dark joint grouts. Particles disintegrating 
from the sauna stones and impurities in the 
sauna water may stain and/or damage sensitive 
floor coverings. 

NOTE! Check from the fire authorities which parts 

of the firewall can be insulated. Flues which are in 
use must not be insulated. 

NOTE! Light protective covers which are installed 

directly to the wall or ceiling may be a fire risk. 

 

2.1.1. Blackening of the Sauna Walls 

It is perfectly normal for the wooden surfaces of the 
sauna room to blacken in time. The blackening may 
be accelerated by 

·

 sunlight 

·

 heat from the heater 

·

 protective agents on the walls (protective 

agents have a poor heat resistance level) 

·

 fine particles disintegrating from the sauna 

stones which rise with the air flow. 

 

 

 

 

 

 

 
 

A. Izolace musí mít tloušťku 50 - 100mm. 

Sauna musí být pečlivě zaizolovaná 
aby se zamezilo ztrátám tepla. 

B. Na izolace se kvůli ochraně před vlhkostí 

dává aluminiová folie směrem dovnitř sauny. 

C. Mezi palubkami a izolací se nechává vzducho- 

va mezera kvůli proudění vzduchu. 

D. Optimální tloušťka obkladu je 12 - 16mm. 

Před pokládáním palubek si natáhněte 
elektrické rozvody za stěnami, aby jste 
předešli následným problémům s elektroinstalací. 

E. Ventilační mezera mezi palubkami a zdí je cca 3mm. 
F. Výška sauny je většinou 2,1 - 2,3m. Minimální výšku 

nad kamny najdete viz. tabulka 3) 
Rozměr mezi horní lavicí a stropem by neměl být větší 
než 120cm. 

G. Pozor při výběru podlahových krytin, 

 

 

 

 

 

 

 

 
 

2.1.1. Černání stěn sauny 

Černání stěn v sauně je zcela normální 
v průběhu času. 
Černání může podpořit. 
- sluneční svit 
- teplo z kamen 
- Tepelné štíty a ochrany 

- Jemné částice, které vypadnou z kamen 

a následně je proudění vzduchu rozvíří 
po sauně.

Содержание FG70

Страница 1: ...CZ FG70 FG90 FG70E FG90E Instructions for Installation and Use of Electric Sauna Heater Instrukce pro instalaci a ovl d n elektrick ch kamen do sauny 25082010 FG FG E...

Страница 2: ...1 Blackening of the Sauna Walls 8 2 2 Sauna Room Ventilation 9 2 3 Heater Output 9 2 4 Sauna Room Hygiene 9 3 INSTRUCTIONS FOR INSTALLATION 10 3 1 Before Installation 10 3 2 Place and Safety Distances...

Страница 3: ...eight on the heating elements Support the heating elements with stones so that the elements stay vertically straight Fig 1 C Do not block the lower or upper end of the air duct Fig 1 D Do not put ston...

Страница 4: ...70 and FG90 are equipped with a timer and a thermostat The timer is for setting the on time for the heater and the thermostat is for setting a suitable temperature 1 3 1 1 3 4 Heater models FG70E and...

Страница 5: ...nature of the heat from soft to sharp by throwing water either to the front of the heater or straight on top of the stones NOTE The maximum volume of the ladle is 0 2 litres If an excessive amount of...

Страница 6: ...e heater may burn your skin Keep children away from the heater Do not let young handicapped or ill people bathe in the sauna on their own Consult your doctor about any health related limitations to ba...

Страница 7: ...room ventilation has been arranged correctly 2 2 The sauna room heats quickly but the temperature of the stones remain insufficient Water thrown on the stones runs through Turn the thermostat to a lo...

Страница 8: ...which are in use must not be insulated NOTE Light protective covers which are installed directly to the wall or ceiling may be a fire risk 2 1 1 Blackening of the Sauna Walls It is perfectly normal fo...

Страница 9: ...to the volume of the sauna Non insulated walls brick glass block glass concrete tile etc increase the need for heater out put Add 1 2 m to the volume of the sauna for each non insulated wall square me...

Страница 10: ...3 je nap t dimenzov no pro va e kamna je spr vn vybran prostor pro kamna 3 2 POZOR V saun mohou b t um st ny pouze jedny kamna D le se mus kamna p ipevnit ke st n viz 3 3 3 3 Um st n a bezpe n vzd len...

Страница 11: ...er than 1000 mm from the sauna floor must be approved for use in a temperature of 125 C marking T125 In addition to supply connectors the FG heaters are equipped with a connector P which makes the con...

Страница 12: ...the electri cal installations a leakage may be detected when measuring the heater s insulation resistance The reason for this is that the insulating material of the heating elements has absorbed mois...

Страница 13: ...long time while unused Is the sensor of the thermostat out of place or broken The correct position for the sensor and replacing the thermostat is illustrated in figure 11 Has the heater been banged o...

Страница 14: ...plech kamen L Bo n plech kamen P Termostat FG70 FG90 FG70 FG70 FG70 FG70 FG70E FG90E FG70E FG90 FG90E FG70E FG90 FG90E FG70E FG90 FG90E FG90 ZRH 720 ZSE 259 ZRH 721 ZRH 715 ZRH 714 ZSK 520 7 9 10 11 T...