Chapter 1
Introduction
14
175-100423-00
Remote GPI Control
Table 1-10
and
Table 1-11
describes the GPI control specifications for the NXAMP3801HDX/HDI:
Table 1-10
GPI output Specifications for the NXAMP3801HDX/HDI
Item
Symbol
Rating
Unit
OUT
8 outputs (16 pin connector)
Load voltage (AC peak/DC)
VOFF
20
VAC
Continuous load current
IO
450
mA
ON resistance
.8 ohms (typical)
5pF
Information correct according to data obtained by OMRON.
WARNINGS:
1 Be sure to turn OFF the power when wiring the Relay, otherwise an electric shock may be
received.
2 Do not apply overvoltage or overcurrent to the I/O circuits of the SSR, otherwise the SSR may
malfunction or burn.
Table 1-11
GPI input Specifications for the NXAMP3801HDX/HDI
Item
Symbol
Rating
Unit
IN
8 inputs (16 pin connector)
Forward current-continuous
IF
60
mA
Forward Current-Peak
IF (pk)
1.0A
A
Reverse Voltage
VR
6.0
V
LED Power Dissipation @ TA=25
ºC
PD
150
mW
Information correct according to data obtained by Fairchild
Remote Serial Interface
The following is a list of the remote serial interface specifications for NXAMP3801HDX/HDI:
RS-422 ports for control of up to eight channels; one port can be allocated for a VTR
RJ-12 connector
Harris ADC VDCP pinout. Refer to
Chapter 4, Connector Pinouts
on page 37.
Содержание NXAMP3801HDI
Страница 1: ...NEXIO AMP Generation 6 Hardware Installation and User Guide 175 100423 00 Rev A ...
Страница 6: ...Table of Contents 6 175 100423 00 ...
Страница 16: ...Chapter 1 Introduction 16 175 100423 00 ...
Страница 30: ...Chapter 2 Chassis Components 30 175 100423 00 ...
Страница 60: ...Chapter 7 How to Create or Rebuild a RAID 1 Boot Drive 60 175 100423 00 ...
Страница 73: ......
Страница 74: ......
Страница 75: ......