33
Save These Instructions
3-90-775R36_09/15
7. Cleaning the Door Glass
• Frequency:
As needed / Weekly
• By:
User
Whenever the view of the fire is obstructed, or weekly,
clean the glass using a soft cloth dampened with standard
household glass cleaner.
Never spray glass cleaner directly onto hot glass. Apply
the cleaner to the cloth then wipe the glass.
Inspect the glass and sealing gasket. Replace gasket as
needed. Do not operate the stove with a broken glass.
Replacement glass, which is mirrored ceramic glass, should
be obtained through your Harman
®
dealer.
To replace a broken glass; first be sure to carefully remove
the broken glass and any remaining shards or pieces. With
the door laying on a flat surface, lay the gasketed glass
panel onto the door and be sure it is properly fitted into the
channel. Lay the glass retainer clips in place near each
corner, and secure them using the 3/8" screws. Be sure to
tighten each screw equally so you don't create a pressure
point on the glass.
NEVER OPERATE THIS APPLIANCE WITH THE
GLASS DOOR REMOVED, CRACKED, BROKEN, OR
SCRATCHED.
8. Venting and Chimney System
• Frequency:
Yearly or more frequently depending on
ash build-up.
• By:
Service Technician / Chimney Sweep
Soot and Fly Ash: Formation & Need for Removal
The products of combustion will contain small particles of fly
ash. The fly ash will collect in the exhaust venting system
and restrict the flow of exhaust gases.
During periods of incomplete combustion, which may occur
during start-up, shut down, or when operated incorrectly,
the fly ash may actually lead to soot formation in the venting
system.
The venting system will need to be cleaned at least once
per year, or more often depending on the quality of the fuel
being used. Horizontal sections of vent pipe are especially
prone to soot formation, as ash will accumulate more quickly.
The chimney and venting system should be inspected
periodically throughout the heating season to determine
if a creosote buildup has occurred. If a significant layer
of creosote has accumulated (3mm or more) it should
be removed to reduce the risk of a chimney fire.
Glass
Adhesive gasket
Door Frame
Retainers and screws
Handle glass with care.
When cleaning door glass;
•
Avoid striking, scratching, or slamming glass.
•
Do NOT Clean Glass When Hot.
•
Do NOT use abrasive cleaners.
•
Inspect gasket, replace if necessary.
CAUTION
!
Содержание P35I
Страница 49: ...49 Save These Instructions 3 90 775R36_09 15 ...