14
Save These Instructions
3-90-775R36_09/15
C. Venting Requirements & Restrictions
A combustion blower is used to extract the combustion gases
from the firebox. This causes a negative pressure in the
firebox and a positive pressure in the venting system. The
longer the vent pipe and more elbows used in the system,
the greater the flow resistance.
The recommended maximum flue lengths for the P35i
Insert are as follows:
4" Flex Pipe:
Maximum 30 Ft. Vertical
3" Flex Pipe:
Maximum 20 Ft. Vertical
Long runs of flex or PL vent pipe installed directly vertical
from the flue stub may require more frequent cleaning due
to fly ash falling off inside and collecting directly above the
combustion blower outlet.
Any use of horizontal venting will require more frequent
cleaning. It is the responsibility of the installer to make sure
the entire flue configuration is accessible for cleaning.
4" stainless steel flex vent piping is only allowed for use
in masonry fireplaces and chimneys or factory built wood
burning fireplaces with class A metal chimneys. All pellet vent
pipe must be secured together either by means provided by
pipe manufacturer or by 3 screws at each joint.
There are two different flue pipe stubs available. The unit
comes standard with the largest pipe stub.
1. Part #1-00-574034 is for use with 4” PL vent starter pipe
and 4” stainless steel flex pipe (Part #1-00-574034).
2. Part #1-00-674039 is for use with 3” PL vent starter pipe
and also for use with 3” aluminum flex duct for outside air
connections.
Use only the specified venting components. Use of any
other components will void the product warranty and
may pose a hazard.
Do Not Install A Flue Damper In The Exhaust Venting
System Of This Appliance.
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE
SERVING ANOTHER APPLIANCE.
WARNING! RISK OF FIRE!
•
Only LISTED type L or PL Pellet venting components
may be used.
•
NO OTHER type of venting materials or components
may be used.
• Substitute or damaged vent components may impair
safe operation.
WARNING! RISK OF INJURY OR PROPERTY DAMAGE!
• Improper installation, adjustment, alteration, service,
or maintenance can cause injury or property damage.
• Read and Refer to your owner's manual.
• For assistance or additional information, consult a
qualified installer, service agency or your dealer.
IN CANADA: This fireplace insert must be installed with
a continuous chimney liner of a minimum 3" diameter
extending from the insert to the top of the chimney. The
chimney liner must conform to the Class 3 requirements
of CAN/ULC-S635, Standard for Lining Systems for
Existing Masonry or Factory Built Chimneys and Vents,
or CAN/ULC-S640, Standard for Lining Systems for
New Masonry Chimneys.
Содержание P35I