17
Save These Instructions
3-90-775R36_09/15
A. Mobile Home Installation
Outside Air Kit
#1-00-774280
Must be used for
installation in a mobile home.
1. An outside air inlet must be provided for combustion
air, and must remain clear of leaves, debris, ice, and/or
snow. The outside air path must be unrestricted while
the appliance is in operation.
2.
The combustion air intake system must be of metal
construction. It must permit zero-clearance to
combustible materials, and contain a rodent screen.
3. The appliance must be secured to the mobile home
structure by bolting it to the floor. Use the correct length
lag-bolts through the same holes that secured the
appliance to the shipping pallet.
4. The appliance must be properly grounded to the frame
of the mobile home using a minimum of 8 AWG copper
solid or stranded, insulated or bare wire or equivalent.
5.
All clearances to combustibles and floor protection
requirements must be followed.
6. Follow the vent manufacturer's instructions when
installing in a mobile home. Use silicone or equivalent
to create an effective vapor barrier where the chimney
or other component penetrates to the exterior of the
mobile home.
7. Installation shall be in accordance with the Manufactured
Home and Safety Standard (HUD) CFR 3280, Part 24.
8. The appliance must never be installed in a room
designated for sleeping.
9. The space heater must be connected to a factory built
chimney conforming to CAN/ULC-S629. Maximum 8
inch diameter. Chimney must be removable to allow
transport of mobile home.
There are a few holes in the bottom of the insert mounting
frame which can be used for lag bolts. Use at least two
of these holes for securing the appliance to the fireplace
floor in a mobile home installation. The installer will need
to determine and obtain the properly sized lag bolts and
masonry anchors.
7
Mobile Home
Maintain structural integrity of mobile home:
• Floor, wall, ceiling and/or roof.
Do
NOT
cut through:
• Floor joist, wall studs, or ceiling trusses.
• Any supporting material that would affect the
structural integrity.
CAUTION
!
Never draw outside combustion air from:
•
Wall, floor or ceiling cavity
• Enclosed space such as an attic or garage
CAUTION
!
Installation must comply with Manufactured Home and
Safety Standard (HUD), CFR 3280, Part 24.
WARNING
!
Never install in a room intended for sleeping.
WARNING
!
Four 5/16 -18 L
eveling
bolts ma
y b
e installed
in each c
orner
Numer
ous holes allo
w
for lag b
olts (2 min.)in
mobile home installa
tion