-Blinks Poor ESP signal.
Broken probe, wire or connection.
Exhaust temperature has gone out of range
multiple times.
Check connection Replace Probe
Clean exhaust- possible soot or creosote
accumulation near probe.
-Blinks Poor Room Sensor
signal.
Broken sensor, wire or connection.
Check connection Replace sensor
5-Blinks ailed ignition
No fuel in hopper
oor, hopper lid, or ash pan open
Poor draft weak combustion blower
uel feed restriction
Blocked airflow Igniter failure
Load fuel
Close all doors and check seals
Perform draft test, clean exhaust, replace blower if
necessary.
Check operation in Test mode. Clear obstruction
Open burn pot cleanout to access igniter- clean.
Check igniter, replace if necessary
-Blinks Poor combustion
No fuel in hopper
oor, hopper lid, or ash pan open
Poor draft weak combustion blower
uel feed restriction
Load fuel
Close all doors and check seals
Perform draft test, clean exhaust, replace blower if
necessary.
Check operation in Test mode. Clear obstruction
Low volume or no fuel feed
No fuel in hopper
oor, hopper lid, or ash pan open
Poor draft weak combustion blower
uel feed restriction
ailed feed motor
Load fuel
Close all doors and check seals
Perform draft test, clean exhaust, replace blower if
necessary.
Check operation in Test mode. Clear obstruction
Replace motor if necessary
No istribution Blower
ire isn t hot enough for blower operation
ANUAL STO E TE P
ailed motor or connections- Test mode
Increase temperature setting
When operating in manual ignite stove temp mode,
the blower will not run below a # setting on the
temperature dial. Increase temperature setting.
Check connections Replace blower
Low heat output, or room tem-
perature doesn t match ther-
mometer or other readings
eed rate too low
Room sensor location different than ther-
mometer location
Excessive ash buildup on heat exchanger
or in the exhaust
Set feed ad uster at # or higher
Room sensor reports the room air temperature to
the circuit board. ove sensor location or ad ust set
point accordingly
Clean exhaust, firebox, and heat exchanger thor-
oughly.
9
Troubleshooting
With proper installation, operation, and maintenance, your appliance will provide years of
trouble-free service. If you do experience a problem, this troubleshooting guide will assist a
qualified service person in proper diagnosis and repair. This guide is intended for qualified
service technician use only.
Error Message Possible Cause Corrective Action
Symptom Possible Cause Corrective Action