J . Shut-Down

uring operation in ROO  TE P  AUTO ATIC mode, 

the appliance will shut down naturally when demand is 

met or exceeded. In other modes of operation, the unit 

will shut-down only if or when it runs out of fuel. 
To  kill  or  stop  a  fire,  turn  the  mode  selector  dial  to 

O

.  The  shut  down  cycle  will  slow  or  stop  the 

feeder to gradually cool the fire and ensure that all of 

the exhaust gases are safely expelled before stopping 

the combustion blower. This not only ensures removal 

of  all  smoke  and  gases,  it  also  keeps  the  fire  from 

attempting to travel into the fuel storage hopper.  or this 

reason   Hearth    Home  Technologies  recommends 

installing  a  battery  back-up  in  areas  where  frequent 

power outages are experienced. (Also see page1 )

NEV ER  ATTEMPT TO K ILL A F IR E BY  PULLING  

THE PLUG  OR  OTHER W ISE DISCONNECTING  

THE ELECTR ICITY  SUPPLY .

The best way to kill a fire, especially at the end of the 

heating season, is to simply allow it to run out of fuel.

I. R elax ation Mode

An added feature for those times when you d like to 

unwind watching a fire but yet do not want all the heat.
With the igniter switch in the  ANUAL  position and 

the mode selector in  STO E TE P , your temperature 

dial can be set up to a #  and the distribution blower 

will be disabled. As you turn up the temperature dial 

and  the  fire  begins  to  burn  hotter,  the  distribution 

blower will begin to operate.

G . Starting a F ire - " AUTOMATIC"

1.  With the mode selector in the  O

 position, and 

the  eed Ad uster 

NOT

 on  Test , plug the power 

cord into a properly grounded receptacle.

2.  ill the hopper with  RY fuel. 

.  Turn the  EE  A USTER dial to  Test . This will 

run the feed motor for one minute. If you begin to 

see fuel entering the burn pot, you can stop the 

test cycle. Return to #  or #5 to start out.

.  Position the Igniter switch to AUTO ATIC.

5.  Turn the mode selector dial to the desired mode. 

This will start the combustion blower, feeder, and 

igniter operating. 

If R oom Temp is selected, be 

sure to turn the temperature dial above the 

current room temperature.

.  After the initial feed cycle is typically when you ll 

begin to see sparks, smoke, or flames.

K eep Hopper Lid, Ash Pan, and F ire viewing doors 

closed while in operation. Maintain all door seals 

and gaskets in good condition. R eplace gaskets 

when necessary using parts obtained through 

your Harman® dealer.

H. Maintaining the F ire

Once  the  istribution  Blower  begins  operation,  your 

fire is well established. Now, you can make any desired 

ad ustments  to  the  temperature  dial.  Remember,  in 

STO E  TE P,  the  temperature  dial  uses  the  inner 

portion of the scale (#1 thru 7). In ROO  TE P, select 

the desired temperature in  ahrenheit from 50 to  0 

degrees.
The flames should appear brisk and bright. If you see 

deep orange and lazy flames, it is usually an indication 

that  the  burn  pot  needs  to  be  cleaned.  Refer  to  the 

aintenance Section of this manual.

Warning!    risK  of  fire!

    eep  combustible 

materials,  gasoline,  and  other  flammable  vapors  or 

liquids clear of this appliance.
• 

NOT

 store flammable materials in the vicinity 

of this appliance.

• 

O  NOT  BURN  GARBAGE  OR  LA

ABLE 

LUI S  SUCH  AS  GASOLINE,  NAPTHA  OR 

ENGINE OIL. 

• 

O  NOT  USE  CHE ICALS  OR  LUI S  TO 

START A  IRE.

Keep all such liquids well away from the heater while it 

is in use, combustible materials may ignite! 

Содержание P35I

Страница 1: ...SUPER ISE children in same room as fireplace Alert children and adults to hazards of high temperatures High temperatures may ignite clothing or other amma e mater a eep clothing furniture draperies an...

Страница 2: ...esign technology and manufacturing Output is managed by a microprocessor that senses the room temperature and the fire temperature with two thermistor probes and then determines the best feed rate for...

Страница 3: ...nd 1 C Routing the Power Cord 1 Securing the ounting rame 20 E Attaching the enting 20 Installing the Body Into The rame 21 G Control Board Installation 21 H Room Sensor Installation 21 I Optional Log...

Страница 4: ...f the mobile home and must never be installed in a room designated for sleeping The unit must have provisions for an outside air source when installed in a mobile home a Spec ficat n This appliance is...

Страница 5: ...atal Even though this stove is designed to be as safe as possible it is recommended that you install a CO detector This is true for oil gas or wood burning products as well CO is not specifically heav...

Страница 6: ...keep the rest of the house comfortable If the sensor is located in an ad acent room or farther away from the stove you will notice higher temperatures near the appliance o NOT connect this unit to a...

Страница 7: ...i o n s 3 90 775R16_08 13 C Component Locations Door Latch F eed Motor Distribution Blower V iewing G lass Pellet Pro F eeder Control Panel Combustion Blower Ex haust Sensing Probe ESP Hopper Lid Latc...

Страница 8: ...he minimum height requirements 10 All labels and hang tags have been removed from the glass 11 All plated surfaces have been wiped clean if applicable 12 The room sensor and any additional cable has b...

Страница 9: ...775R16_08 13 4 Dimensions Clearances A Appliance Dimensions 14 35 56 cm 22 55 88 cm 8 20 32 cm 10 25 4 cm 2 5 08 cm 24 60 96 cm A B 19 1 2 49 53 cm Hopper 23 1 2 59 69 cm Hopper 23 3 4 60 32 cm A 4 0...

Страница 10: ...to face trim Insert top to max 12 mantel F E Location Inches illimeters Window opening to front 152 152 Window opening to side D Minimum Opening for Masonry and Manufactured F ireplaces I I H G Locati...

Страница 11: ...nstallation is contingent upon the authority having urisdiction Note If the Harman P 5i Insert is installed into a factory built wood burning fireplace this label Harman part 0 00 75 UST be attached t...

Страница 12: ...ance to an outside corner is 11 from center of pipe G The clearance to an inside corner is 12 H A vent must not be installed within feet 0 cm above a gas meter regulator assembly when measured from th...

Страница 13: ...roof vented The air intake is best located on the exterior wall oriented towards the prevailing wind direction during the heating season The outside air connection will supply the demands of the pell...

Страница 14: ...or use in masonry fireplaces and chimneys or in factory built wood burning fireplace installations when used as a liner for a class A metal chimney All pellet vent pipe must be secured together by mea...

Страница 15: ...This is to prevent overheating of the fireplace cavity which may cause damage to the insert s motors and other electrical components The connector pipe should extend through the sealing plate and smok...

Страница 16: ...so be sealed Otherwise it can become a nesting area or a water trap If passing through combustible material the proper thimble from the vent manufacturer must be used Masonry wall 3 Clearance Zero Cle...

Страница 17: ...r component penetrates to the exterior of the mobile home 7 Installation shall be in accordance with the anufactured Home and Safety Standard HU C R 280 Part 2 8 The appliance must never be installed...

Страница 18: ...he mounting frame through the sealing plate Then install the chimney top extension kit item 1 00 7 10 at the top of the chimney This is slotted to allow fresh air into the chimney or chase 2 Secure th...

Страница 19: ...tion 1 Remove the insert body from the mounting frame 2 Start your leveling bolts into the floor of the frame and ad ust to slightly raise the height see next section This will allow some clearance to...

Страница 20: ...he angle of the collar as needed Shown above is the vertical position and the horizontal position Be sure the fiber gasket remains in place between the collar and the mounting frame and secure the bol...

Страница 21: ...ts attached to the short brown wire from the control harness The white wire from the power cord will attach to the short white wire on the control harness Install the control panel into the surround R...

Страница 22: ...ided drill bit Install the trim frame with the threaded studs through the holes in the door and secure it with the four nuts provided in the kit Set screw Roll Pin K Service R ail K it 1 0 0 7 7 4 1 2...

Страница 23: ...the cleanest sawdust Cleaning and maintenance are greatly reduced while typically higher heat value is experienced APPR OV ED F UELS Wood Pellets Any grade of wood or biomass pelletized fuel Pellets...

Страница 24: ...ported temperatures and demand temperature The circuit board will also flash a code sequence on the Status light if an error is detected ESP Location feed adjuster Sets the maximum feed rate Test Runs...

Страница 25: ...air temperature Note that on the coldest days your indoor heated space will be cooler than on the warmer days The only real benefit to this mode of operation is that you ll be able to know exactly how...

Страница 26: ...screw on the circuit board See Page 2 Clockwise will increase the draft and counter clockwise will decrease it Once set record the low draft reading here W C Be sure and turn off of Test mode isconne...

Страница 27: ...eed Ad uster NOT on Test plug the power cord into a properly grounded receptacle 2 ill the hopper with RY fuel Turn the EE A USTER dial to Test This will run the feed motor for one minute If you begin...

Страница 28: ...draft weak combustion blower uel feed restriction ailed feed motor Load fuel Close all doors and check seals Perform draft test clean exhaust replace blower if necessary Check operation in Test mode...

Страница 29: ...tch inspection Prior to heating season OR X eeder body ines collection area epending on fuel quality OR X irebox thorough cleaning After each ton of fuel burned OR X Glass When view of fire becomes ob...

Страница 30: ...quantity of fuel consumed the interval between scraping will vary If you see orange and lazy flames it is a good indicator of the need for scraping 2 Ash R emoval F rom F irebox F req uency Weekly dep...

Страница 31: ...n of fuel is burned By User It is recommended that you use a vacuum that is designed for ash as ashes may block conventional vacuum filters NOTICE or optimal performance of your pellet burning applian...

Страница 32: ...ing screws one per f Brush or vacuum the remaining ash from the firebox g Guide the vacuum hose upward into the exhaust passage in the right rear corner of the firebox h You can now return all pieces...

Страница 33: ...glass door removed cracKed broKen or scraTched CAUTION Handle glass with care en c ean n r a Avoid striking scratching or slamming glass o NOT Clean Glass When Hot o NOT use abrasive cleaners Inspect...

Страница 34: ...a ve T h e se I n st r u ct i o n s 0 775R1 08 1 D Motors and Components F eed Motor Distribution Blower Pellet Pro F eeder Combustion Blower Ex haust Sensing Probe ESP F rame Latch Ash Pan Latch Door...

Страница 35: ...t cloth and glass cleaner or alcohol To remove the probe Slide the insert body out of the mounting frame The probe is installed on the side of the exhaust chamber With a 1 socket or driver remove the...

Страница 36: ...crews using a 5 1 driver or wrench 8 screws 5 F eeder Body Wipe or vacuum to clean Use a vacuum to remove fines and sawdust To access feeder cleanout Slide the insert body out of the mounting frame Lo...

Страница 37: ...ve wire ties as needed to loosen the igniter wires Pull the igniter and bracket out from the front until the wire disconnects are accessible When installing igniter reverse these steps and be sure tha...

Страница 38: ...T BLUE N O CONTACTS COMBUSTION MOTOR LT BLUE MALE FEMALE CONNECTIONS 1 3 2 WHITE PLUGGED BROWN 5 6 7 EMPTY WHITE WHITE WHITE 4 8 10 9 RED BLUE YELLOW PART NO 3 90 00877 BLACK 11 WHITE 11 PIN PLUG MALE...

Страница 39: ...Your appliance will pulse the blower every few seconds to clear exhaust until the fire is out NOTE The UPS provides safe shut down only It is not intended for continued operation Your appliance will...

Страница 40: ...ge 2 3 5 in 1 7 0 7 7 4 2 3 5 1 Black 1 9 5 in 1 7 0 7 7 4 1 9 5 1 Black Ending Manufacturing Date J une 2 0 1 1 2 3 5 in 1 7 0 7 7 4 2 3 5 2 Charcoal 1 7 0 7 7 4 2 3 5 3 G oldenfire 1 9 5 in 1 7 0 7...

Страница 41: ...18 1 1 Pkg of 50 0 112 50 Y Wing Assembly Oversize Black 1 00 77 250 1 No longer available 1 00 77 250 2 No longer available 1 00 77 250 Custom 1 00 77 221 SPL 1 Surround Top Standard 1 10 77 222 Over...

Страница 42: ...5155 1 10 77 150A Y 1 5 in Hopper Pre 008 5155 1 10 77 028A Y Post 008 5155 1 10 77 128A Y Switch Hopper Lid 8 in 20 2 2108 Y 1 8 1 2 Silicone PSA 20 T or hopper top 1 00 75501 Y 1 Spring Latch ty req...

Страница 43: ...wing page 1 t Power cord 20 7 200 Y 0 W 120 Igniter 15 in 20 77200 Y Pkg of 10 1 00 77200 Y Airwash O rings Pkg of 10 1 00 Y Ash Lip Trim Gold 08 00 Brushed Stainless 08 00 7 Bright Nickel 08 00 8 Bur...

Страница 44: ...over it 1 00 7 00 Y 1 Tubing it 5 t 1 00 511 27 Y 27 7 1 8 Silicone Tubing 5 t 1 00 511 57 Y 27 8 Screws HWH TE S 10 Pkg of 100 0 500 100 Y 27 Pellet Air Intake w Gasket 1 10 0 810A 27 10 Gasket eeder...

Страница 45: ...imum Height P35i Custom Surround Part 1 00 774221 SPL The top of the mounting frame must be covered at this point u t m S e Surr un This diagram shows the minimum dimensions of a custom fit surround p...

Страница 46: ...tion warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whichever occurs earlier Th...

Страница 47: ...y does not cover the following Changes in surface finishes as a result of normal use As a heating appliance some changes in color of interior and exterior surface finishes may occur This is not a flaw...

Страница 48: ...e t s o r C o r n P e l l e t M i xt u r e O n l y P3 5 i F ireplace Insert S a ve T h e se I n st r u ct i o n s 3 90 775R16_08 13 Service Maintenance Log Date Of Service Performed By Description Of...

Страница 49: ...P e l l e t s o r C o r n P e l l e t M i xt u r e O n l y P3 5 i F ireplace Insert S a ve T h e se I n st r u ct i o n s 3 90 775R16_08 13...

Страница 50: ...e This powerful heating appliance boasts uncompromising attention to detail and helps preserve our planet by using environmentally responsible fuels Signature of Boxer Your premium quality hearth prod...

Отзывы: